These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 11145808)

  • 1. 2000 Volvo Award winner in biomechanical studies: Monitoring in vivo implant loads with a telemeterized internal spinal fixation device.
    Rohlmann A; Graichen F; Weber U; Bergmann G
    Spine (Phila Pa 1976); 2000 Dec; 25(23):2981-6. PubMed ID: 11145808
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability.
    Rohlmann A; Bergmann G; Graichen F; Mayer HM
    Spine (Phila Pa 1976); 1995 Dec; 20(24):2683-9. PubMed ID: 8747246
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of muscle forces on loads in internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Mayer HM
    Spine (Phila Pa 1976); 1998 Mar; 23(5):537-42. PubMed ID: 9530784
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Loads on an internal spinal fixation device during walking.
    Rohlmann A; Bergmann G; Graichen F
    J Biomech; 1997 Jan; 30(1):41-7. PubMed ID: 8970923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Loads on an internal spinal fixation device during physical therapy.
    Rohlmann A; Graichen F; Bergmann G
    Phys Ther; 2002 Jan; 82(1):44-52. PubMed ID: 11784277
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Loads on internal spinal fixators measured in different body positions.
    Rohlmann A; Bergmann G; Graichen F
    Eur Spine J; 1999; 8(5):354-9. PubMed ID: 10552317
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo measurement of implant loads in a patient with a fractured vertebral body.
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Eur Spine J; 1995; 4(6):347-53. PubMed ID: 8983654
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Loads on a telemeterized vertebral body replacement measured in two patients.
    Rohlmann A; Graichen F; Kayser R; Bender A; Bergmann G
    Spine (Phila Pa 1976); 2008 May; 33(11):1170-9. PubMed ID: 18469689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Braces do not reduce loads on internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Neff G
    Clin Biomech (Bristol); 1999 Feb; 14(2):97-102. PubMed ID: 10619096
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is it possible to simulate physiologic loading conditions by applying pure moments? A comparison of in vivo and in vitro load components in an internal fixator.
    Wilke HJ; Rohlmann A; Neller S; Schultheiss M; Bergmann G; Graichen F; Claes LE
    Spine (Phila Pa 1976); 2001 Mar; 26(6):636-42. PubMed ID: 11246374
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Changes in the loads on an internal spinal fixator after iliac-crest autograft.
    Rohlmann A; Bergmann G; Graichen F; Weber U
    J Bone Joint Surg Br; 2000 Apr; 82(3):445-9. PubMed ID: 10813187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Loads on internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Orthopade; 1999 May; 28(5):451-457. PubMed ID: 28246960
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo implant forces acting on a vertebral body replacement during upper body flexion.
    Dreischarf M; Albiol L; Zander T; Arshad R; Graichen F; Bergmann G; Schmidt H; Rohlmann A
    J Biomech; 2015 Feb; 48(4):560-565. PubMed ID: 25640900
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Loading on internal spinal fixation devices].
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Orthopade; 1999 May; 28(5):451-7. PubMed ID: 10394604
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month.
    Rohlmann A; Graichen F; Bender A; Kayser R; Bergmann G
    Clin Biomech (Bristol); 2008 Feb; 23(2):147-58. PubMed ID: 17983694
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Spinal load bearing during sitting in an office chair with a tilting back].
    Rohlmann A; Wilke HJ; Graichen F; Bergmann G
    Biomed Tech (Berl); 2002 Apr; 47(4):91-6. PubMed ID: 12051139
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of loads on internal spinal fixation devices measured in vitro and in vivo.
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Med Eng Phys; 1997 Sep; 19(6):539-46. PubMed ID: 9394902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measured loads on a vertebral body replacement during sitting.
    Rohlmann A; Zander T; Graichen F; Dreischarf M; Bergmann G
    Spine J; 2011 Sep; 11(9):870-5. PubMed ID: 21775218
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Stress measurements with an instrumented internal spinal fixator].
    Rohlmann A; Eick O; Bergmann G; Graichen F
    Biomed Tech (Berl); 1993 Oct; 38(10):255-9. PubMed ID: 8268404
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Loads on an internal spinal fixation device during sitting.
    Rohlmann A; Arntz U; Graichen F; Bergmann G
    J Biomech; 2001 Aug; 34(8):989-93. PubMed ID: 11448690
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.