These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 11147150)

  • 1. Experimental and clinical assessment of the accuracy of knee extension measurement techniques.
    Jagodzinski M; Kleemann V; Angele P; Schönhaar V; Iselborn KW; Mall G; Nerlich M
    Knee Surg Sports Traumatol Arthrosc; 2000; 8(6):329-36. PubMed ID: 11147150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of digital compass goniometer in knee joint range of motion measurement.
    Yaikwawongs N; Limpaphayom N; Wilairatana V
    J Med Assoc Thai; 2009 Apr; 92(4):517-22. PubMed ID: 19374303
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians.
    Milanese S; Gordon S; Buettner P; Flavell C; Ruston S; Coe D; O'Sullivan W; McCormack S
    Man Ther; 2014 Dec; 19(6):569-74. PubMed ID: 24942491
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Test-Retest Reliability of a New Device Versus a Long-Arm Goniometer to Evaluate Knee Proprioception.
    Tian F; Zhao Y; Li J; Wang W; Wu D; Li Q; Guo L; Wang S
    J Sport Rehabil; 2022 Mar; 31(3):368-373. PubMed ID: 34784583
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.
    Dos Santos RA; Derhon V; Brandalize M; Brandalize D; Rossi LP
    J Bodyw Mov Ther; 2017 Jul; 21(3):699-703. PubMed ID: 28750987
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Repeatability of goniometer measurements of the knee in patients wearing an Ilizarov external fixator: a clinic-based study.
    Barker KL; Lamb SE; Burns M; Simpson AH
    Clin Rehabil; 1999 Apr; 13(2):156-63. PubMed ID: 10348396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Goniometer crosstalk compensation for knee joint applications.
    de Oliveira Sato T; Hansson GÅ; Coury HJ
    Sensors (Basel); 2010; 10(11):9994-10005. PubMed ID: 22163452
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Verification of selected anatomic landmarks used as reference points for universal goniometer positioning during knee joint mobility range measurements.
    Szulc P; Lewandowski J; Marecki B
    Med Sci Monit; 2001; 7(2):312-5. PubMed ID: 11257742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting.
    Watkins MA; Riddle DL; Lamb RL; Personius WJ
    Phys Ther; 1991 Feb; 71(2):90-6; discussion 96-7. PubMed ID: 1989012
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inter- and intraobserver variability of radiographic measurements of knee alignment.
    Ilahi OA; Kadakia NR; Huo MH
    Am J Knee Surg; 2001; 14(4):238-42. PubMed ID: 11703037
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Concurrent validity and reliability of the Simple Goniometer iPhone app compared with the Universal Goniometer.
    Jones A; Sealey R; Crowe M; Gordon S
    Physiother Theory Pract; 2014 Oct; 30(7):512-6. PubMed ID: 24666408
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Computerized tomography assessment of femoral and tibial rotation in total knee prosthesis].
    Rimondi E; Molinari M; Moio A; Busacca M; Trentani F; Trentani P; Tigani D; Nigrisoli M
    Radiol Med; 2000 Jun; 99(6):420-5. PubMed ID: 11262817
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions.
    Brosseau L; Balmer S; Tousignant M; O'Sullivan JP; Goudreault C; Goudreault M; Gringras S
    Arch Phys Med Rehabil; 2001 Mar; 82(3):396-402. PubMed ID: 11245764
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty.
    Lenssen AF; van Dam EM; Crijns YH; Verhey M; Geesink RJ; van den Brandt PA; de Bie RA
    BMC Musculoskelet Disord; 2007 Aug; 8():83. PubMed ID: 17705860
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Smartphone assessment of knee flexion compared to radiographic standards.
    Dietz MJ; Sprando D; Hanselman AE; Regier MD; Frye BM
    Knee; 2017 Mar; 24(2):224-230. PubMed ID: 28179062
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improving goniometer accuracy by compensating for individual transducer characteristics.
    Sato Tde O; Coury HJ; Hansson GA
    J Electromyogr Kinesiol; 2009 Aug; 19(4):704-9. PubMed ID: 18316206
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of perioperative flexion-extension mechanics of the knee joint.
    Giori NJ; Giori KL; Woolson ST; Goodman SB; Lannin JV; Schurman DJ
    J Arthroplasty; 2001 Oct; 16(7):877-81. PubMed ID: 11607904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does medio-lateral motion occur in the normal knee? An in-vitro study in passive motion.
    Belvedere C; Leardini A; Giannini S; Ensini A; Bianchi L; Catani F
    J Biomech; 2011 Mar; 44(5):877-84. PubMed ID: 21176906
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement of the knee range of motion: standard goniometer or smartphone?].
    Rwakabayiza S; Pereira LC; Lécureux E; Jolles-Haeberli B
    Rev Med Suisse; 2013 Dec; 9(411):2372-5. PubMed ID: 24693586
    [TBL] [Abstract][Full Text] [Related]  

  • 20. EOS orthopaedic imaging system to study patellofemoral kinematics: assessment of uncertainty.
    Azmy C; Guérard S; Bonnet X; Gabrielli F; Skalli W
    Orthop Traumatol Surg Res; 2010 Feb; 96(1):28-36. PubMed ID: 20170853
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.