292 related articles for article (PubMed ID: 11149438)
1. Accuracy and reliability of the self-inflating bulb to verify tracheal intubation in out-of-hospital cardiac arrest patients.
Tanigawa K; Takeda T; Goto E; Tanaka K
Anesthesiology; 2000 Dec; 93(6):1432-6. PubMed ID: 11149438
[TBL] [Abstract][Full Text] [Related]
2. Efficacy of the self-inflating bulb in confirming tracheal intubation in the morbidly obese.
Lang DJ; Wafai Y; Salem MR; Czinn EA; Halim AA; Baraka A
Anesthesiology; 1996 Aug; 85(2):246-53. PubMed ID: 8712438
[TBL] [Abstract][Full Text] [Related]
3. The efficacy of esophageal detector devices in verifying tracheal tube placement: a randomized cross-over study of out-of-hospital cardiac arrest patients.
Tanigawa K; Takeda T; Goto E; Tanaka K
Anesth Analg; 2001 Feb; 92(2):375-8. PubMed ID: 11159235
[TBL] [Abstract][Full Text] [Related]
4. The self-inflating bulb to detect esophageal intubation during emergency airway management.
Kasper CL; Deem S
Anesthesiology; 1998 Apr; 88(4):898-902. PubMed ID: 9579497
[TBL] [Abstract][Full Text] [Related]
5. The assessment of three methods to verify tracheal tube placement in the emergency setting.
Takeda T; Tanigawa K; Tanaka H; Hayashi Y; Goto E; Tanaka K
Resuscitation; 2003 Feb; 56(2):153-7. PubMed ID: 12589988
[TBL] [Abstract][Full Text] [Related]
6. Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation.
Bozeman WP; Hexter D; Liang HK; Kelen GD
Ann Emerg Med; 1996 May; 27(5):595-9. PubMed ID: 8629780
[TBL] [Abstract][Full Text] [Related]
7. Effectiveness of the self-inflating bulb for verification of proper placement of the Esophageal Tracheal Combitube.
Wafai Y; Salem MR; Baraka A; Joseph NJ; Czinn EA; Paulissian R
Anesth Analg; 1995 Jan; 80(1):122-6. PubMed ID: 7802268
[TBL] [Abstract][Full Text] [Related]
8. Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.
Goldberg JS; Rawle PR; Zehnder JL; Sladen RN
Anesth Analg; 1990 Feb; 70(2):191-4. PubMed ID: 2105671
[TBL] [Abstract][Full Text] [Related]
9. Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device.
Ornato JP; Shipley JB; Racht EM; Slovis CM; Wrenn KD; Pepe PE; Almeida SL; Ginger VF; Fotre TV
Ann Emerg Med; 1992 May; 21(5):518-23. PubMed ID: 1570906
[TBL] [Abstract][Full Text] [Related]
10. Validity of a disposable end-tidal CO2 detector in verifying endotracheal tube placement in infants and children.
Bhende MS; Thompson AE; Cook DR; Saville AL
Ann Emerg Med; 1992 Feb; 21(2):142-5. PubMed ID: 1739199
[TBL] [Abstract][Full Text] [Related]
11. End-tidal CO2 measurement in the detection of esophageal intubation during cardiac arrest.
Sayah AJ; Peacock WF; Overton DT
Ann Emerg Med; 1990 Aug; 19(8):857-60. PubMed ID: 2115315
[TBL] [Abstract][Full Text] [Related]
12. Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest.
Hayden SR; Sciammarella J; Viccellio P; Thode H; Delagi R
Acad Emerg Med; 1995 Jun; 2(6):499-502. PubMed ID: 7497049
[TBL] [Abstract][Full Text] [Related]
13. Efficacy of the self-inflating bulb in detecting esophageal intubation. Does the presence of a nasogastric tube or cuff deflation make a difference?
Salem MR; Wafai Y; Joseph NJ; Baraka A; Czinn EA
Anesthesiology; 1994 Jan; 80(1):42-8. PubMed ID: 8291728
[TBL] [Abstract][Full Text] [Related]
14. Use of the self-inflating bulb for detecting esophageal intubation after "esophageal ventilation".
Salem MR; Wafai Y; Baraka A; Taimorrazy B; Joseph NJ; Nimmagadda U
Anesth Analg; 1993 Dec; 77(6):1227-31. PubMed ID: 8250317
[TBL] [Abstract][Full Text] [Related]
15. The esophageal detector device. Does it work?
Zaleski L; Abello D; Gold MI
Anesthesiology; 1993 Aug; 79(2):244-7. PubMed ID: 8342836
[TBL] [Abstract][Full Text] [Related]
16. The out-of-hospital esophageal and endobronchial intubations performed by emergency physicians.
Timmermann A; Russo SG; Eich C; Roessler M; Braun U; Rosenblatt WH; Quintel M
Anesth Analg; 2007 Mar; 104(3):619-23. PubMed ID: 17312220
[TBL] [Abstract][Full Text] [Related]
17. Verification of endotracheal tube position.
Salem MR
Anesthesiol Clin North Am; 2001 Dec; 19(4):813-39. PubMed ID: 11778382
[TBL] [Abstract][Full Text] [Related]
18. Efficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section.
Baraka A; Khoury PJ; Siddik SS; Salem MR; Joseph NJ
Anesth Analg; 1997 Mar; 84(3):533-7. PubMed ID: 9052296
[TBL] [Abstract][Full Text] [Related]
19. The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system.
Silvestri S; Ralls GA; Krauss B; Thundiyil J; Rothrock SG; Senn A; Carter E; Falk J
Ann Emerg Med; 2005 May; 45(5):497-503. PubMed ID: 15855946
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Upper Airway Ultrasonography Against Quantitative Waveform Capnography for Validating Endotracheal Tube Position in a South Indian Population.
Malamal Pradeep S; Ann Benny H
Cureus; 2024 Jan; 16(1):e52628. PubMed ID: 38374868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]