These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 11155531)
1. [Precision MRI-based joint surface and cartilage density analysis of the knee joint using rapid water-excitation sequence and semi-automatic segmentation algorithm]. Heudorfer L; Hohe J; Faber S; Englmeier KH; Reiser M; Eckstein F Biomed Tech (Berl); 2000 Nov; 45(11):304-10. PubMed ID: 11155531 [TBL] [Abstract][Full Text] [Related]
2. Gender differences in knee joint cartilage thickness, volume and articular surface areas: assessment with quantitative three-dimensional MR imaging. Faber SC; Eckstein F; Lukasz S; Mühlbauer R; Hohe J; Englmeier KH; Reiser M Skeletal Radiol; 2001 Mar; 30(3):144-50. PubMed ID: 11357452 [TBL] [Abstract][Full Text] [Related]
3. Precision of tibial cartilage morphometry with a coronal water-excitation MR sequence. Hyhlik-Dürr A; Faber S; Burgkart R; Stammberger T; Maag KP; Englmeier KH; Reiser M; Eckstein F Eur Radiol; 2000; 10(2):297-303. PubMed ID: 10663760 [TBL] [Abstract][Full Text] [Related]
4. Quantitative relationships of normal cartilage volumes of the human knee joint--assessment by magnetic resonance imaging. Eckstein F; Winzheimer M; Westhoff J; Schnier M; Haubner M; Englmeier KH; Reiser M; Putz R Anat Embryol (Berl); 1998 May; 197(5):383-90. PubMed ID: 9623672 [TBL] [Abstract][Full Text] [Related]
5. In vivo morphometry and functional analysis of human articular cartilage with quantitative magnetic resonance imaging--from image to data, from data to theory. Eckstein F; Reiser M; Englmeier KH; Putz R Anat Embryol (Berl); 2001 Mar; 203(3):147-73. PubMed ID: 11303902 [TBL] [Abstract][Full Text] [Related]
6. [Three-dimensional thickness and volume measurements of the knee joint cartilage by MR tomography: reproducibility in volunteers]. Westhoff J; Eckstein F; Sittek H; Lösch A; Faber S; Kolem H; Englmeier KH; Reiser M Rofo; 1997 Dec; 167(6):585-90. PubMed ID: 9465953 [TBL] [Abstract][Full Text] [Related]
7. In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging. Eckstein F; Westhoff J; Sittek H; Maag KP; Haubner M; Faber S; Englmeier KH; Reiser M AJR Am J Roentgenol; 1998 Mar; 170(3):593-7. PubMed ID: 9490936 [TBL] [Abstract][Full Text] [Related]
8. Application of a semi-automatic cartilage segmentation method for biomechanical modeling of the knee joint. Liukkonen MK; Mononen ME; Tanska P; Saarakkala S; Nieminen MT; Korhonen RK Comput Methods Biomech Biomed Engin; 2017 Oct; 20(13):1453-1463. PubMed ID: 28895760 [TBL] [Abstract][Full Text] [Related]
9. Automatic segmentation of articular cartilage in magnetic resonance images of the knee. Fripp J; Crozier S; Warfield SK; Ourselin S Med Image Comput Comput Assist Interv; 2007; 10(Pt 2):186-94. PubMed ID: 18044568 [TBL] [Abstract][Full Text] [Related]
10. Optimization and validation of a rapid high-resolution T1-w 3D FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness. Glaser C; Faber S; Eckstein F; Fischer H; Springer V; Heudorfer L; Stammberger T; Englmeier KH; Reiser M Magn Reson Imaging; 2001 Feb; 19(2):177-85. PubMed ID: 11358655 [TBL] [Abstract][Full Text] [Related]
11. Thirty Minutes of Running Exercise Decreases T2 Signal Intensity but Not Thickness of the Knee Joint Cartilage: A 3.0-T Magnetic Resonance Imaging Study. Karanfil Y; Babayeva N; Dönmez G; Diren HB; Eryılmaz M; Doral MN; Korkusuz F Cartilage; 2019 Oct; 10(4):444-450. PubMed ID: 29676169 [TBL] [Abstract][Full Text] [Related]
12. Determination of 3D cartilage thickness data from MR imaging: computational method and reproducibility in the living. Stammberger T; Eckstein F; Englmeier KH; Reiser M Magn Reson Med; 1999 Mar; 41(3):529-36. PubMed ID: 10204876 [TBL] [Abstract][Full Text] [Related]
13. Quantitative assessment of patellar cartilage volume and thickness at 3.0 tesla comparing a 3D-fast low angle shot versus a 3D-true fast imaging with steady-state precession sequence for reproducibility. Weckbach S; Mendlik T; Horger W; Wagner S; Reiser MF; Glaser C Invest Radiol; 2006 Feb; 41(2):189-97. PubMed ID: 16428992 [TBL] [Abstract][Full Text] [Related]
14. [Three-dimensional thickness and volume measurements of the knee joint cartilage using MRI: validation in an anatomical specimen by CT arthrography]. Schnier M; Eckstein F; Priebsch J; Haubner M; Sittek H; Becker C; Putz R; Englmeier KH; Reiser M Rofo; 1997 Nov; 167(5):521-6. PubMed ID: 9440900 [TBL] [Abstract][Full Text] [Related]
15. Femoro-tibial cartilage metrics from coronal MR image data: Technique, test-retest reproducibility, and findings in osteoarthritis. Glaser C; Burgkart R; Kutschera A; Englmeier KH; Reiser M; Eckstein F Magn Reson Med; 2003 Dec; 50(6):1229-36. PubMed ID: 14648571 [TBL] [Abstract][Full Text] [Related]
16. [Knee joint cartilage in magnetic resonance tomography. MR chondrovolumetry (MR-CVM) using fat-suppressed FLASH 3D sequence]. Eckstein F; Sittek H; Gavazzeni A; Milz S; Kiefer B; Putz R; Reiser M Radiologe; 1995 Feb; 35(2):87-93. PubMed ID: 7740121 [TBL] [Abstract][Full Text] [Related]