These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 11159227)
1. Transesophageal echocardiographic imaging of a new aortic cannula for differential perfusion during cardiopulmonary bypass. Rehfeldt KH; Cook DJ Anesth Analg; 2001 Feb; 92(2):338-40. PubMed ID: 11159227 [TBL] [Abstract][Full Text] [Related]
2. Echocardiographic comparison of the standard end-hole cannula, the soft-flow cannula, and the dispersion cannula during perfusion into the aortic arch. Grooters RK; Ver Steeg DA; Stewart MJ; Thieman KC; Schneider RF Ann Thorac Surg; 2003 Jun; 75(6):1919-23. PubMed ID: 12822636 [TBL] [Abstract][Full Text] [Related]
3. Changes in aortic rotational flow during cardiopulmonary bypass studied by transesophageal echocardiography and magnetic resonance velocity imaging: a potential mechanism for atheroembolism during cardiopulmonary bypass. Koh TW; Parker KH; Kon M; Pepper JR Heart Vessels; 2001 Dec; 16(1):1-8. PubMed ID: 11829212 [TBL] [Abstract][Full Text] [Related]
4. Breakdown of atheromatous plaque due to shear force from arterial perfusion cannula. Fukuda I; Minakawa M; Fukui K; Taniguchi S; Daitoku K; Suzuki Y; Hashimoto H Ann Thorac Surg; 2007 Oct; 84(4):e17-8. PubMed ID: 17888949 [TBL] [Abstract][Full Text] [Related]
5. Femoral artery cannulation for thoracic aortic surgery: safe under transesophageal echocardiographic control. Ayyash B; Tranquilli M; Elefteriades JA J Thorac Cardiovasc Surg; 2011 Dec; 142(6):1478-81. PubMed ID: 22093716 [TBL] [Abstract][Full Text] [Related]
6. Differential perfusion: a new technique for isolated brain cooling during cardiopulmonary bypass. Boston US; Sungurtekin H; McGregor CG; Macoviak JA; Cook DJ Ann Thorac Surg; 2000 May; 69(5):1346-50. PubMed ID: 10881803 [TBL] [Abstract][Full Text] [Related]
7. Atherosclerotic arch aneurysm operations with perfusion toward the aortic valve. Yamana K; Ito T; Maekawa A; Yoshizumi T; Sunada M; Hoshino S Ann Thorac Surg; 2010 Feb; 89(2):435-9. PubMed ID: 20103317 [TBL] [Abstract][Full Text] [Related]
8. Assessment of perfusion toward the aortic valve using the new dispersion aortic cannula during coronary artery bypass surgery. Grooters RK; Thieman KC; Schneider RF; Nelson MG Tex Heart Inst J; 2000; 27(4):361-5. PubMed ID: 11198309 [TBL] [Abstract][Full Text] [Related]
9. Transesophageal echocardiography of the proximal aortic arch after cardiopulmonary bypass. Amir IM; Béïque F J Cardiothorac Vasc Anesth; 2002 Aug; 16(4):521-3. PubMed ID: 12154438 [No Abstract] [Full Text] [Related]
10. Effect of cannula length on aortic arch flow: protection of the atheromatous aortic arch. Grossi EA; Kanchuger MS; Schwartz DS; McLoughlin DE; LeBoutillier M; Ribakove GH; Marschall KE; Galloway AC; Colvin SB Ann Thorac Surg; 1995 Mar; 59(3):710-2. PubMed ID: 7887717 [TBL] [Abstract][Full Text] [Related]
11. Cannulation in the diseased aorta: a safe approach using the Seldinger technique. Khoynezhad A; Plestis KA Tex Heart Inst J; 2006; 33(3):353-5. PubMed ID: 17041694 [TBL] [Abstract][Full Text] [Related]
12. A Phase 1 Study of a Novel Bidirectional Perfusion Cannula in Patients Undergoing Femoral Cannulation for Cardiac Surgery. Marasco SF; Tutungi E; Vallance SA; Udy AA; Negri JC; Zimmet AD; McGiffin DC; Pellegrino VA; Moshinsky RA Innovations (Phila); 2018; 13(2):97-103. PubMed ID: 29697598 [TBL] [Abstract][Full Text] [Related]
13. Utility of transesophageal echocardiography during port-access minimally invasive cardiac surgery. Applebaum RM; Cutler WM; Bhardwaj N; Colvin SB; Galloway AC; Ribakove GH; Grossi EA; Schwartz DS; Anderson RV; Tunick PA; Kronzon I Am J Cardiol; 1998 Jul; 82(2):183-8. PubMed ID: 9678289 [TBL] [Abstract][Full Text] [Related]
14. Anesthetic Considerations for Surgery on the Aortic Arch. Wilkey BJ; Weitzel NS Semin Cardiothorac Vasc Anesth; 2016 Dec; 20(4):265-272. PubMed ID: 27821785 [TBL] [Abstract][Full Text] [Related]
15. Computational Modeling of Neonatal Cardiopulmonary Bypass Hemodynamics With Full Circle of Willis Anatomy. Piskin S; Ündar A; Pekkan K Artif Organs; 2015 Oct; 39(10):E164-75. PubMed ID: 25940836 [TBL] [Abstract][Full Text] [Related]
16. Effectiveness of the Cobra aortic catheter for dual-temperature management during adult cardiac surgery. Cook DJ; Orszulak TA; Zehr KJ; Nussmeier NA; Livesay JJ; Hammon JW; Chen X J Thorac Cardiovasc Surg; 2003 Feb; 125(2):378-84. PubMed ID: 12579108 [TBL] [Abstract][Full Text] [Related]
17. Aortic outflow cannula tip design and orientation impacts cerebral perfusion during pediatric cardiopulmonary bypass procedures. Menon PG; Antaki JF; Undar A; Pekkan K Ann Biomed Eng; 2013 Dec; 41(12):2588-602. PubMed ID: 23817768 [TBL] [Abstract][Full Text] [Related]
18. Risk factor analysis for ascending aorta and aortic arch repair using selective cerebral perfusion with open technique: role of open-stent graft placement. Nakamura K; Onitsuka T; Yano M; Yano Y; Matsuyama M; Furukawa K J Cardiovasc Surg (Torino); 2006 Dec; 47(6):659-65. PubMed ID: 17043612 [TBL] [Abstract][Full Text] [Related]
19. Neonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass. Pekkan K; Dur O; Sundareswaran K; Kanter K; Fogel M; Yoganathan A; Undar A J Biomech Eng; 2008 Dec; 130(6):061012. PubMed ID: 19045541 [TBL] [Abstract][Full Text] [Related]
20. Decreased cerebral emboli during distal aortic arch cannulation: a randomized clinical trial. Borger MA; Taylor RL; Weisel RD; Kulkarni G; Benaroia M; Rao V; Cohen G; Fedorko L; Feindel CM J Thorac Cardiovasc Surg; 1999 Oct; 118(4):740-5. PubMed ID: 10504642 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]