These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 11172578)

  • 1. Equipment for mixed gas and oxygen therapy.
    Barnes TA
    Respir Care Clin N Am; 2000 Dec; 6(4):545-95, viii. PubMed ID: 11172578
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fixed performance oxygen masks. Hypoxic hazard of low-capacity drugs.
    Cox D; Gillbe C
    Anaesthesia; 1981 Oct; 36(10):958-64. PubMed ID: 7304885
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of six types of oxygen delivery devices at varying respiratory rates.
    Wagstaff TA; Soni N
    Anaesthesia; 2007 May; 62(5):492-503. PubMed ID: 17448063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The rear or the front in bag and mask oxygenation of the neonates.
    Fayez Bakr A; El-Altar A
    J Trop Pediatr; 2006 Oct; 52(5):382. PubMed ID: 16246850
    [No Abstract]   [Full Text] [Related]  

  • 5. Clearing the air. Ensuring proper oxygen concentration delivery from medical gas systems.
    Health Devices; 2010 Apr; 39(4):126-31. PubMed ID: 21305935
    [No Abstract]   [Full Text] [Related]  

  • 6. Efficiency of oxygen administration: sequential gas delivery versus "flow into a cone" methods.
    Slessarev M; Somogyi R; Preiss D; Vesely A; Sasano H; Fisher JA
    Crit Care Med; 2006 Mar; 34(3):829-34. PubMed ID: 16505664
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Oxygen concentrations at the rear and front of the bag in bag valve mask devices during oxygenation of neonates.
    Bakr AF; El-Attar A
    Resuscitation; 2005 Aug; 66(2):217-23. PubMed ID: 16053945
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixed performance oxygen masks: an evaluation.
    Hill SL; Barnes PK; Hollway T; Tennant R
    Br Med J (Clin Res Ed); 1984 Apr; 288(6426):1261-3. PubMed ID: 6424819
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High oxygen flow can create a powerful anterograde water stream when utilizing a bubble-over humidification system.
    Bolash R; Chen J; Lesser J; Resta-Flarer F
    Anesth Analg; 2012 Oct; 115(4):981. PubMed ID: 23002264
    [No Abstract]   [Full Text] [Related]  

  • 10. Oxygen and aerosolized drug delivery: matching the device to the patient.
    Burkhart JE; Stoller JK
    Cleve Clin J Med; 1998 Apr; 65(4):200-8. PubMed ID: 9597785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Reliability of Venturi oxygen therapy systems].
    Gómez Seco J; Rodríguez Nieto MJ; Heili S; Sabillón O; Fernández I; Ortega A; González Mangado N
    Arch Bronconeumol; 2003 Jun; 39(6):256-60. PubMed ID: 12797941
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Maximum FIO2 in minimum time depending on the kind of resuscitation bag and oxygen flow.
    Quintana S; Martínez Pérez J; Alvarez M; Vila JS; Jara F; Nava JM
    Intensive Care Med; 2004 Jan; 30(1):155-8. PubMed ID: 14551682
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of blow-by methods in delivering oxygen to pediatric patients during transport: A laboratory study.
    Barends CRM; Yavuz P; Molenbuur B; Absalom AR
    Paediatr Anaesth; 2018 Dec; 28(12):1142-1147. PubMed ID: 30375103
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility and practical considerations for heating and humidifying gases during newborn stabilisation: an in vitro model.
    Owen LS; Dawson JA; Middleburgh R; Buttner S; McGrory L; Davis PG
    Neonatology; 2014; 106(2):156-62. PubMed ID: 24993671
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mere nuisance or worse? Oxygen tubing obstruction by flowmeter outlet connector.
    Martin TM; Porter RJ
    Anesth Analg; 1994 Dec; 79(6):1208-9. PubMed ID: 7978454
    [No Abstract]   [Full Text] [Related]  

  • 16. Humidity and Inspired Oxygen Concentration During High-Flow Nasal Cannula Therapy in Neonatal and Infant Lung Models.
    Chikata Y; Ohnishi S; Nishimura M
    Respir Care; 2017 May; 62(5):532-537. PubMed ID: 28174331
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Techniques to avoid intubation: noninvasive positive pressure ventilation and heliox therapy.
    Hess D; Chatmongkolchart S
    Int Anesthesiol Clin; 2000; 38(3):161-87. PubMed ID: 10984852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risks posed by the use of oxygen therapy and non-invasive positive pressure ventilation: a pilot study.
    Hui DS; Hall S; Chan MT; Joynt GM; Chow B; Sung JJ
    Hong Kong Med J; 2009 Dec; 15 Suppl 8():4-7. PubMed ID: 20393203
    [No Abstract]   [Full Text] [Related]  

  • 19. Oxygen conserving devices and methodologies.
    Tiep B; Carter R
    Chron Respir Dis; 2008; 5(2):109-14. PubMed ID: 18539725
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delivered oxygen fraction during simulated cardiopulmonary resuscitation depending on the kind of resuscitation bag and oxygen flow.
    Ariño Irujo JJ; Velasco JM; Moral P; Carrillo B; López-Timoneda F
    Eur J Emerg Med; 2012 Dec; 19(6):359-62. PubMed ID: 22044931
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.