151 related articles for article (PubMed ID: 11190620)
1. [Biliary endo-to-end anastomosis with extramucosal titanium clips. Initial results of a new technique].
Birth M; Gerberding J; Markert U; Wohlschläger C; Brugmans F; Bruch HP
Zentralbl Chir; 2000; 125(12):990-6. PubMed ID: 11190620
[TBL] [Abstract][Full Text] [Related]
2. Vascular closure staples-a new technique for biliary reconstruction: prospective randomized comparison with manual suture in an animal model.
Birth M; Markert U; Strik M; Wohlschläger C; Brugmans F; Gerberding J; Bruch HP
Transplantation; 2002 Jan; 73(1):31-8. PubMed ID: 11792974
[TBL] [Abstract][Full Text] [Related]
3. Five years' world experience with nonpenetrating clips for vascular anastomoses.
Zeebregts CJ; Kirsch WM; van den Dungen JJ; Zhu YH; van Schilfgaarde R
Am J Surg; 2004 Jun; 187(6):751-60. PubMed ID: 15191871
[TBL] [Abstract][Full Text] [Related]
4. A quick and simple method to close vascular, biliary, and urinary tract incisions using the new Vascular Closure Staples: a preliminary report.
Leppäniemi AK; Wherry DC; Soltero RG; Pikoulis E; Hufnagel HV; Fishback N; Rich NM
Surg Endosc; 1996 Jul; 10(7):771-4. PubMed ID: 8662439
[TBL] [Abstract][Full Text] [Related]
5. Sutureless anastomoses using magnetic rings in canine liver transplantation model.
Liu SQ; Lei P; Cui XH; Lv Y; Li JH; Song YL; Zhao G
J Surg Res; 2013 Dec; 185(2):923-33. PubMed ID: 23972622
[TBL] [Abstract][Full Text] [Related]
6. Evolution of staples and clips for vascular anastomoses.
Zeebregts CJ; Kirsch WM; van den Dungen JJ; van Schilfgaarde R; Zhu YH
Int Surg; 2004; 89(3):152-60. PubMed ID: 15521252
[TBL] [Abstract][Full Text] [Related]
7. Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses.
Geevarghese SK; Bradley AL; Atkinson J; Wright JK; Chapman WC; Van Buren DH; Blair KT; Hutchins CH; Jabbour K; Phillips J; Williams PE; Pinson CW
Am Surg; 1999 Apr; 65(4):311-6. PubMed ID: 10190352
[TBL] [Abstract][Full Text] [Related]
8. Continuous versus interrupted suture for end-to-end biliary anastomosis during liver transplantation gives equal results.
Castaldo ET; Pinson CW; Feurer ID; Wright JK; Gorden DL; Kelly BS; Chari RS
Liver Transpl; 2007 Feb; 13(2):234-8. PubMed ID: 17256781
[TBL] [Abstract][Full Text] [Related]
9. [Bile duct reconstruction in liver transplantation].
Decurtins M; Lachat M; Largiadèr F
Helv Chir Acta; 1990 Jun; 57(1):83-6. PubMed ID: 2228693
[TBL] [Abstract][Full Text] [Related]
10. Duct-to-duct biliary anastomosis with a "corner-saving suture" technique in living-related liver transplantation.
Dalgic A; Moray G; Emiroglu R; Sozen H; Karakayali H; Boyacioglu S; Bilgin N; Haberal M
Transplant Proc; 2005 Sep; 37(7):3137-40. PubMed ID: 16213329
[TBL] [Abstract][Full Text] [Related]
11. Non-penetrating vascular clips anastomosis inhibited intimal thickening under poor runoff conditions in canine autogenous vein grafts.
Komori K; Shoji T; Furuyama T; Yonemitsu Y; Mori E; Yamaoka T; Matsumoto T; Sugimachi K
Eur J Vasc Endovasc Surg; 2001 Mar; 21(3):241-7. PubMed ID: 11352683
[TBL] [Abstract][Full Text] [Related]
12. Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs.
Calles-Vázquez MC; Viguera FJ; Crisóstomo V; Usón-Gargallo J
Ann Vasc Surg; 2006 Jan; 20(1):35-41. PubMed ID: 16378146
[TBL] [Abstract][Full Text] [Related]
13. Vascular closure system type of nonpenetrating arcuate-legged titanium clips for graft-artery and graft-graft anastomoses: review of our clinical experience.
Inoue Y; Kubota T; Jibiki M; Hirokawa M; Sugano N; Iwai T
Surg Today; 2004; 34(3):231-6. PubMed ID: 14999535
[TBL] [Abstract][Full Text] [Related]
14. Sutureless vascular reconstruction with titanium clips.
Leppäniemi A; Rich N; Pikoulis E; Rhee P; Burris D; Wherry D
Int Angiol; 2000 Mar; 19(1):69-74. PubMed ID: 10853689
[TBL] [Abstract][Full Text] [Related]
15. Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomoses in rabbit vein grafts.
Caiati JM; Madigan JD; Bhagat G; Benvenisty AI; Nowygrod R; Todd GJ
J Surg Res; 2000 Jul; 92(1):29-35. PubMed ID: 10864478
[TBL] [Abstract][Full Text] [Related]
16. Rapid arterial anastomosis with titanium clips.
Pikoulis E; Burris D; Rhee P; Nishibe T; Leppäniemi A; Wherry D; Rich N
Am J Surg; 1998 Jun; 175(6):494-6. PubMed ID: 9645780
[TBL] [Abstract][Full Text] [Related]
17. [VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat].
Gerbault O; Arrouvel C; Servant JM; Revol M; Banzet P
Ann Chir Plast Esthet; 1998 Feb; 43(1):27-39. PubMed ID: 9768090
[TBL] [Abstract][Full Text] [Related]
18. Interventional radiology techniques in the treatment of complications due to videolaparoscopic cholecystectomy.
Rossi M; Salvatori FM; Giglio L; Fanelli F; Cantisani V; Rossi P; David V
Radiol Med; 2002 Apr; 103(4):384-95. PubMed ID: 12107389
[TBL] [Abstract][Full Text] [Related]
19. [Prevention and management of biliary complications following orthotopic liver transplantation].
Yang ZY; Dong JH; Wang SG; Bie P
Zhonghua Wai Ke Za Zhi; 2003 Apr; 41(4):260-3. PubMed ID: 12882667
[TBL] [Abstract][Full Text] [Related]
20. Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis.
Matthews BD; Pratt BL; Backus CL; Kercher KW; Mostafa G; Lentzner A; Lipford EH; Sing RF; Heniford BT
Am Surg; 2001 Sep; 67(9):901-6. PubMed ID: 11565773
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]