These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 11190782)

  • 1. MegaDyne Mega 2000 return electrode.
    Health Devices; 2000 Dec; 29(12):445-60. PubMed ID: 11190782
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noncontact electrosurgical grounding is useful in burn surgery.
    Sheridan RL; Wilson NC; O'Connell MF; Fabri JA
    J Burn Care Rehabil; 2003; 24(6):400-1. PubMed ID: 14610427
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Higher currents, greater risks: preventing patient burns at the return-electrode site during high-current electrosurgical procedures.
    ECRI
    Health Devices; 2005 Aug; 34(8):273-9. PubMed ID: 16255231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Safety technologies for laparoscopic monopolar electrosurgery; devices for managing burn risks.
    ECRI
    Health Devices; 2005 Aug; 34(8):259-72. PubMed ID: 16255230
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noncontact electrosurgical grounding--a useful and safe tool in the initial surgical management of thermal injuries.
    Liodaki E; Stang FH; Lohmeyer JA; Bergmann PA; Mailänder P; Siemers F
    Burns; 2013 Feb; 39(1):142-5. PubMed ID: 22738829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrosurgery: part II. Technology, applications, and safety of electrosurgical devices.
    Taheri A; Mansoori P; Sandoval LF; Feldman SR; Pearce D; Williford PM
    J Am Acad Dermatol; 2014 Apr; 70(4):607.e1-607.e12. PubMed ID: 24629362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization and mitigation of stray radiofrequency currents during monopolar resectoscopic electrosurgery.
    Vilos GA; Newton DW; Odell RC; Abu-Rafea B; Vilos AG
    J Minim Invasive Gynecol; 2006; 13(2):134-40. PubMed ID: 16527716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Guidance section: ensuring monopolar electrosurgical safety during laparoscopy.
    Health Devices; 1995 Jan; 24(1):20-6. PubMed ID: 7713716
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monitoring instrumentation. Isolated inputs, electrosurgery filtering, burns protection: what does it mean?
    Uyttendaele K; Grobstein S; Svetz P
    Acta Anaesthesiol Belg; 1978; 29(3):317-30. PubMed ID: 751436
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo evaluation of monopolar versus bipolar electrosurgical polypectomy snares.
    Tucker RD; Platz CE; Sievert CE; Vennes JA; Silvis SE
    Am J Gastroenterol; 1990 Oct; 85(10):1386-90. PubMed ID: 2220733
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrosurgical active electrode shielding systems.
    Health Devices; 1995 Dec; 24(12):492-4. PubMed ID: 8789629
    [No Abstract]   [Full Text] [Related]  

  • 12. Numerical field calculation of patient return electrodes in electrosurgery.
    Raiser J; Golombeck MA; Dössel O
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():274-7. PubMed ID: 12451837
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sparking from and ignition of damaged electrosurgical electrode cables.
    Health Devices; 1998 Aug; 27(8):301-3. PubMed ID: 9743903
    [No Abstract]   [Full Text] [Related]  

  • 14. Skin lesions from aggressive adhesive on Valleylab electrosurgical return electrode pads.
    Health Devices; 1995 Apr; 24(4):159-60. PubMed ID: 7615395
    [No Abstract]   [Full Text] [Related]  

  • 15. Skin burns resulting from the use of conductive distention/irrigation media during electrosurgery with a rollerablation electrode.
    ECRI
    Health Devices; 2005 Aug; 34(8):283-4. PubMed ID: 16255233
    [No Abstract]   [Full Text] [Related]  

  • 16. Investigating the role of capacitive coupling between the operating table and the return electrode of an electrosurgery unit in the modification of the current density distribution within the patients' body.
    Bifulco P; Massa R; Cesarelli M; Romano M; Fratini A; Gargiulo GD; McEwan AL
    Biomed Eng Online; 2013 Aug; 12():80. PubMed ID: 23937865
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bacterial transference during electrodesiccation and electrocoagulation.
    Bennett RG; Kraffert CA
    Arch Dermatol; 1990 Jun; 126(6):751-5. PubMed ID: 2346319
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrosurgical generators and monopolar and bipolar electrosurgery.
    Vilos GA; Rajakumar C
    J Minim Invasive Gynecol; 2013; 20(3):279-87. PubMed ID: 23659748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Return-electrode-site burns associated with Rita Medical Systems Model 1500 and 1500X radio-frequency generators.
    ECRI
    Health Devices; 2005 Aug; 34(8):280-2. PubMed ID: 16255232
    [No Abstract]   [Full Text] [Related]  

  • 20. Gynecologic and dermatologic electrosurgical units: a comparative review.
    Ferris DG; Saxena S; Hainer BL; Searle JR; Powell JL; Gay JN
    J Fam Pract; 1994 Aug; 39(2):160-9. PubMed ID: 8057067
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.