These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
198 related articles for article (PubMed ID: 11206804)
1. Evaluation of the retention dependence on the physicochemical properties of solutes in reversed-phase liquid chromatographic linear gradient elution based on linear solvation energy relationships. Li J; Cai B J Chromatogr A; 2001 Jan; 905(1-2):35-46. PubMed ID: 11206804 [TBL] [Abstract][Full Text] [Related]
2. Prediction of internal standards in reversed-phase liquid chromatography. 1. Initial study on predicting internal standards for use with neutral samples based on linear solvation energy relationships. Li J J Chromatogr A; 2001 Aug; 927(1-2):19-30. PubMed ID: 11572388 [TBL] [Abstract][Full Text] [Related]
3. Characterizing the selectivity of stationary phases and organic modifiers in reversed-phase high-performance liquid chromatographic systems by a general solvation equation using gradient elution. Du CM; Valko K; Bevan C; Reynolds D; Abraham MH J Chromatogr Sci; 2000 Nov; 38(11):503-11. PubMed ID: 11105774 [TBL] [Abstract][Full Text] [Related]
4. Selectivity of amino-, cyano- and diol-bonded silica in reversed-phase liquid chromatography. Kim IW; Lee HS; Lee YK; Jang MD; Par JH J Chromatogr A; 2001 Apr; 915(1-2):35-42. PubMed ID: 11358260 [TBL] [Abstract][Full Text] [Related]
5. New approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography. Nikitas P; Pappa-Louisi A J Chromatogr A; 2005 Mar; 1068(2):279-87. PubMed ID: 15830934 [TBL] [Abstract][Full Text] [Related]
6. A novel method for characterization and comparison of reversed-phase column selectivity. Wang J; Wang C; Guo Z; Dong X; Xiao Y; Xue X; Zhang X; Liang X J Chromatogr A; 2014 Sep; 1361():153-61. PubMed ID: 25155063 [TBL] [Abstract][Full Text] [Related]
7. Prediction of elution bandwidth for purine compounds by a retention model in reversed-phase HPLC with linear-gradient elution. Jin CH; Lee JW; Row KH J Sep Sci; 2008 Jan; 31(1):23-9. PubMed ID: 18064619 [TBL] [Abstract][Full Text] [Related]
8. [Fast optimization of stepwise gradient conditions for ternary mobile phase in reversed-phase high performance liquid chromatography]. Shan YC; Zhang YK; Zhao RH Se Pu; 2002 Jul; 20(4):289-94. PubMed ID: 12541907 [TBL] [Abstract][Full Text] [Related]
9. Comparative study of solvation parameter models accounting the effects of mobile phase composition in reversed-phase liquid chromatography. Torres-Lapasió JR; Ruiz-Angel MJ; García-Alvarez-Coque MC J Chromatogr A; 2007 Sep; 1166(1-2):85-96. PubMed ID: 17720177 [TBL] [Abstract][Full Text] [Related]
10. Comparison of the retention characteristics of aromatic and aliphatic reversed phases for HPLC using linear solvation energy relationships. Zhao J; Carr PW Anal Chem; 1998 Sep; 70(17):3619-28. PubMed ID: 9737212 [TBL] [Abstract][Full Text] [Related]
11. Comparative study of hydrocarbon, fluorocarbon, and aromatic bonded RP-HPLC stationary phases by linear solvation energy relationships. Reta M; Carr PW; Sadek PC; Rutan SC Anal Chem; 1999 Aug; 71(16):3484-96. PubMed ID: 10464478 [TBL] [Abstract][Full Text] [Related]
12. Extension of the linear solvent strength retention model including a parameter that describes the elution strength changes in liquid chromatography. Baeza-Baeza JJ; García-Alvarez-Coque MC J Chromatogr A; 2020 Mar; 1615():460757. PubMed ID: 31831147 [TBL] [Abstract][Full Text] [Related]
13. Optimisation technique for stepwise gradient elution in reversed-phase liquid chromatography. Nikitas P; Pappa-Louisi A; Papachristos K J Chromatogr A; 2004 Apr; 1033(2):283-9. PubMed ID: 15088749 [TBL] [Abstract][Full Text] [Related]
14. Retention characteristics of an immobilized artificial membrane column in reversed-phase liquid chromatography. Lepont C; Poole CF J Chromatogr A; 2002 Feb; 946(1-2):107-24. PubMed ID: 11873960 [TBL] [Abstract][Full Text] [Related]
15. Determination of reversed-phase high performance liquid chromatography based octanol-water partition coefficients for neutral and ionizable compounds: Methodology evaluation. Liang C; Qiao JQ; Lian HZ J Chromatogr A; 2017 Dec; 1528():25-34. PubMed ID: 29103597 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of a reversed-phase column (supelcosil LC-ABZ) under isocratic and gradient elution conditions for estimating octanol-water partition coefficients. Dias NC; Nawas MI; Poole CF Analyst; 2003 May; 128(5):427-33. PubMed ID: 12790192 [TBL] [Abstract][Full Text] [Related]
17. Benefits of solvent concentration pulses in retention time modelling of liquid chromatography. Navarro-Huerta JA; Gisbert-Alonso A; Torres-Lapasió JR; García-Alvarez-Coque MC J Chromatogr A; 2019 Jul; 1597():76-88. PubMed ID: 30902430 [TBL] [Abstract][Full Text] [Related]
18. Linear solvation energy relationships in micellar liquid chromatography and micellar electrokinetic capillary chromatography. Yang S; Khaledi MG J Chromatogr A; 1995 Feb; 692(1-2):301-10. PubMed ID: 7719457 [TBL] [Abstract][Full Text] [Related]
20. Investigation of retention behavior of drug molecules in supercritical fluid chromatography using linear solvation energy relationships. Bui H; Masquelin T; Perun T; Castle T; Dage J; Kuo MS J Chromatogr A; 2008 Oct; 1206(2):186-95. PubMed ID: 18771773 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]