These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
198 related articles for article (PubMed ID: 11212049)
1. Lateral recumbent head-down posture for epidural catheter insertion reduces intravascular injection. Bahar M; Chanimov M; Cohen ML; Friedland M; Grinshpon Y; Brenner R; Shul I; Datsky R; Sherman DJ Can J Anaesth; 2001 Jan; 48(1):48-53. PubMed ID: 11212049 [TBL] [Abstract][Full Text] [Related]
2. The lateral recumbent head-down position decreases the incidence of epidural venous puncture during catheter insertion in obese parturients. Bahar M; Chanimov M; Cohen ML; Friedland M; Shul I; Gofman V; Gershfeld S; Geller R; Sherman DJ Can J Anaesth; 2004; 51(6):577-80. PubMed ID: 15197121 [TBL] [Abstract][Full Text] [Related]
3. Accidental venous and dural puncture during epidural analgesia in obese parturients (BMI > 40 kg/m2): three different body positions during insertion. Chanimov M; Evron S; Haitov Z; Stolero S; Cohen ML; Friedland M; Shul I; Bahar M J Clin Anesth; 2010 Dec; 22(8):614-8. PubMed ID: 21109134 [TBL] [Abstract][Full Text] [Related]
5. Intrathecal catheter insertion during labour reduces the risk of post-dural puncture headache. Dennehy KC; Rosaeg OP Can J Anaesth; 1998 Jan; 45(1):42-5. PubMed ID: 9466026 [TBL] [Abstract][Full Text] [Related]
6. Predistention of the epidural space before catheter insertion reduces the incidence of intravascular epidural catheter insertion. Evron S; Gladkov V; Sessler DI; Khazin V; Sadan O; Boaz M; Ezri T Anesth Analg; 2007 Aug; 105(2):460-4. PubMed ID: 17646506 [TBL] [Abstract][Full Text] [Related]
7. Decreased incidence of complications in parturients with the arrow (FlexTip Plus) epidural catheter. Banwell BR; Morley-Forster P; Krause R Can J Anaesth; 1998 Apr; 45(4):370-2. PubMed ID: 9597214 [TBL] [Abstract][Full Text] [Related]
8. [Combined subarachnoid-epidural technique for obstetric analgesia]. Fernández-Guisasola J; García del Valle S; Gómez-Arnau JI Rev Esp Anestesiol Reanim; 2000 May; 47(5):207-15. PubMed ID: 10902451 [TBL] [Abstract][Full Text] [Related]
9. A systematic review of randomized controlled trials that evaluate strategies to avoid epidural vein cannulation during obstetric epidural catheter placement. Mhyre JM; Greenfield ML; Tsen LC; Polley LS Anesth Analg; 2009 Apr; 108(4):1232-42. PubMed ID: 19299793 [TBL] [Abstract][Full Text] [Related]
10. Internal jugular vein compression to assess the correct placement of an epidural catheter in postpartum women. Chilvers J; Geoghegan J; Moore P; Shah J Anaesthesia; 2007 Apr; 62(4):332-4. PubMed ID: 17381567 [TBL] [Abstract][Full Text] [Related]
11. Soft catheters reduce the risk of intravascular cannulation during epidural block--a retrospective analysis of 1,117 cases in a medical center. Shih CK; Wang FY; Shieh CF; Huang JM; Lu IC; Wu LC; Lu DV Kaohsiung J Med Sci; 2012 Jul; 28(7):373-6. PubMed ID: 22726899 [TBL] [Abstract][Full Text] [Related]
12. Injecting saline through the epidural needle decreases the iv epidural catheter placement rate during combined spinal-epidural labour analgesia. Gadalla F; Lee SH; Choi KC; Fong J; Gomillion MC; Leighton BL Can J Anaesth; 2003 Apr; 50(4):382-5. PubMed ID: 12670816 [TBL] [Abstract][Full Text] [Related]
14. Epidural analgesia in parturients with previous spinal irradiation. Hilton AB; Lockhart EM; Penning DH Can J Anaesth; 1998 Sep; 45(9):884-7. PubMed ID: 9818113 [TBL] [Abstract][Full Text] [Related]
15. Intrathecal analgesia for labor. Wildman KM; Mohl VK; Cassel JH; Houston RE; Allerheiligen DA J Fam Pract; 1997 Jun; 44(6):535-40. PubMed ID: 9191624 [TBL] [Abstract][Full Text] [Related]
16. Posture and epidural catheter insertion. The relationship between skill, experience and maternal posture on the outcome of epidural catheter insertion. Stone PA; Kilpatrick AW; Thorburn J Anaesthesia; 1990 Nov; 45(11):920-3. PubMed ID: 2252185 [TBL] [Abstract][Full Text] [Related]
17. [Reliability of the epidural test dose]. Rosenstock CV; Dahl JB Ugeskr Laeger; 1998 Jun; 160(25):3699-704. PubMed ID: 9641053 [TBL] [Abstract][Full Text] [Related]
18. The optimal distance that a multiorifice epidural catheter should be threaded into the epidural space. Beilin Y; Bernstein HH; Zucker-Pinchoff B Anesth Analg; 1995 Aug; 81(2):301-4. PubMed ID: 7618719 [TBL] [Abstract][Full Text] [Related]
19. The effect of injection of two vs 10 mL saline on the subsequent spread and quality of epidural analgesia in parturients. Siddik-Sayyid SM; Taha SK; Aouad MT; Daaboul DG; Deeb PG; El Khatib MF; Baraka AS J Clin Anesth; 2006 Dec; 18(8):575-9. PubMed ID: 17175425 [TBL] [Abstract][Full Text] [Related]
20. The use of a sound-enabled device to measure pressure during insertion of an epidural catheter in women in labour. Lechner TJ; van Wijk MG; Jongenelis AA; Rybak M; van Niekerk J; Langenberg CJ Anaesthesia; 2011 Jul; 66(7):568-73. PubMed ID: 21539528 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]