These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 11217876)

  • 21. Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.
    Park J; Kim JY; Kim HD; Kim YC; Seo A; Je M; Mun JU; Kim B; Park IH; Kim SY
    Int J Comput Assist Radiol Surg; 2017 May; 12(5):855-864. PubMed ID: 28063078
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?
    Sangeux M; Mahy J; Graham HK
    Gait Posture; 2014 Jan; 39(1):12-6. PubMed ID: 23787150
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Three-dimensional measurement of femoral neck anteversion and neck shaft angle.
    Sangeux M; Pascoe J; Graham HK; Ramanauskas F; Cain T
    J Comput Assist Tomogr; 2015; 39(1):83-5. PubMed ID: 25354092
    [TBL] [Abstract][Full Text] [Related]  

  • 24. CT measurement of anteversion in the femoral neck. The influence of femur positioning.
    Hermann KL; Egund N
    Acta Radiol; 1997 Jul; 38(4 Pt 1):527-32. PubMed ID: 9240672
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Femoral neck anteversion measurement using linear slot scanning radiography.
    Chimhundu C; Sivarasu S; Steiner S; Smit J; Douglas TS
    Med Eng Phys; 2016 Feb; 38(2):187-91. PubMed ID: 26776374
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Three-dimensional CT imaging in the treatment of children's developmental dislocation of hip].
    Jiang H; Miao WS; Yuan HJ; Yu JG
    Zhongguo Gu Shang; 2009 Jun; 22(6):460-2. PubMed ID: 19594050
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy and Reliability of Computed Tomography and Magnetic Resonance Imaging Compared With True Anatomic Femoral Version.
    Beebe MJ; Wylie JD; Bodine BG; Kapron AL; Maak TG; Mei-Dan O; Aoki SK
    J Pediatr Orthop; 2017 Jun; 37(4):e265-e270. PubMed ID: 28244927
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Femoral anteversion in children with cerebral palsy. Assessment with two and three-dimensional computed tomography scans.
    Davids JR; Marshall AD; Blocker ER; Frick SL; Blackhurst DW; Skewes E
    J Bone Joint Surg Am; 2003 Mar; 85(3):481-8. PubMed ID: 12637435
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Utility of Preoperative Femoral Neck Geometry in Predicting Femoral Stem Anteversion.
    Park KK; Tsai TY; Dimitriou D; Kwon YM
    J Arthroplasty; 2015 Jun; 30(6):1079-84. PubMed ID: 25683295
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Femoral torsion: CT measurement.
    Mahboubi S; Horstmann H
    Radiology; 1986 Sep; 160(3):843-4. PubMed ID: 3737928
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Is there a relationship between femoral anteversion and leg torsion?
    Reikerås O
    Skeletal Radiol; 1991; 20(6):409-11. PubMed ID: 1925671
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements.
    Morvan G; Guerini H; Carré G; Vuillemin V
    AJR Am J Roentgenol; 2017 Aug; 209(2):W93-W99. PubMed ID: 28570094
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effects of intertrochanteric osteotomy plane and preoperative femoral anteversion on the postoperative morphology of the proximal femur in transtrochanteric anterior rotational osteotomy: 3D CT-based simulation study.
    Sonoda K; Motomura G; Ikemura S; Kubo Y; Yamamoto T; Nakashima Y
    Orthop Traumatol Surg Res; 2017 Nov; 103(7):1005-1010. PubMed ID: 28782700
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Defining the medial-lateral axis of the femur: Medical imaging, conventional and functional calibration methods lead to differences in hip rotation kinematics for children with torsional deformities.
    Passmore E; Graham HK; Sangeux M
    J Biomech; 2018 Mar; 69():156-163. PubMed ID: 29395228
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development and Validation of a Mobile Application for Measuring Femoral Anteversion in Patients With Cerebral Palsy.
    Sung KH; Youn K; Chung CY; Kitta MI; Kumara HC; Min JJ; Lee J; Park MS
    J Pediatr Orthop; 2020 Jul; 40(6):e516-e521. PubMed ID: 32501925
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Femoral anteversion.
    Murphy SB; Simon SR; Kijewski PK; Wilkinson RH; Griscom NT
    J Bone Joint Surg Am; 1987 Oct; 69(8):1169-76. PubMed ID: 3667647
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Ultrasound measurement of femur neck anteversion].
    Elke R; Ebneter A; Dick W; Fliegel C; Morscher E
    Z Orthop Ihre Grenzgeb; 1991; 129(2):156-63. PubMed ID: 1829297
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [The measurement of the femoral torsion angle in children by NMR tomography compared to CT and ultrasound].
    Tomczak R; Günther K; Pfeifer T; Häberle HJ; Rieber A; Danz B; Rilinger N; Friedrich JM; Brambs HJ
    Rofo; 1995 Mar; 162(3):224-8. PubMed ID: 7718777
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-dimensional computerized tomographic analysis of the deformity of lateral growth disturbance of proximal femoral physis.
    Joo SY; Oh CW; Grissom L; Kumar SJ; MacEwen GD
    J Pediatr Orthop; 2009 Sep; 29(6):540-6. PubMed ID: 19700980
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Computed tomographic measurement of the angle of torsion of the femoral neck. Experimental reliability study on dry bone].
    Morvan G; Testard S; Busson J; Cartier S
    Rev Chir Orthop Reparatrice Appar Mot; 1987; 73(7):511-6. PubMed ID: 3438507
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.