These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 11219598)

  • 1. Evaluation of the long-term functional outcome assessed by myocardial perfusion scintigraphy following excimer laser angioplasty compared to balloon angioplasty in longer coronary lesions.
    Appelman YE; Piek JJ; van der Wall EE; Redekop WK; van Royen EA; Fioretti PM; de Feyter PJ; Koolen JJ; Strikwerda S; Serruys PW; David GK; Tijssen JG; Lie KI
    Int J Card Imaging; 2000 Aug; 16(4):267-77. PubMed ID: 11219598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of myocardial perfusion and function using gated methoxy-isobutyl-isonitrile scintigraphy to detect restenosis after coronary angioplasty.
    Avery PG; Hudson NM; Hubner PJ
    Coron Artery Dis; 1993 Dec; 4(12):1097-102. PubMed ID: 8162241
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Exercise technetium-99m sestamibi tomography for cardiac risk stratification of patients with stable chest pain.
    Stratmann HG; Williams GA; Wittry MD; Chaitman BR; Miller DD
    Circulation; 1994 Feb; 89(2):615-22. PubMed ID: 8313549
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of restenosis after percutaneous transluminal coronary angioplasty using the exercise treadmill test and technetium 99m-sestamibi scintigraphy.
    Srimahachota S; Limpijankit T; Boonyaratavej S; Tepmongkol S; Udayachalerm W; Suithichaiyakul T; Ngarmukos P
    J Med Assoc Thai; 2001 Mar; 84(3):307-13. PubMed ID: 11460930
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease.
    Appelman YE; Piek JJ; Strikwerda S; Tijssen JG; de Feyter PJ; David GK; Serruys PW; Margolis JR; Koelemay MJ; Montauban van Swijndregt EW; Koolen JJ
    Lancet; 1996 Jan; 347(8994):79-84. PubMed ID: 8538345
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Immediate and late outcome of excimer laser and balloon coronary angioplasty: a quantitative angiographic comparison based on matched lesions.
    Strikwerda S; Montauban van Swijndregt E; Foley DP; Boersma E; Umans VA; Melkert R; Serruys PW
    J Am Coll Cardiol; 1995 Oct; 26(4):939-46. PubMed ID: 7560621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Excimer laser angioplasty versus balloon angioplasty in functional and total coronary occlusions.
    Appelman YE; Koolen JJ; Piek JJ; Redekop WK; de Feyter PJ; Strikwerda S; David GK; Serruys PW; Tijssen JG; van Swijnregt E; Lie KI
    Am J Cardiol; 1996 Oct; 78(7):757-62. PubMed ID: 8857478
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Role of stress myocardial perfusion scintigraphy in the follow-up of patients undergoing coronary angioplasty: comparison between qualitative and semi-quantitative analysis].
    Cappelletti A; Fragasso G; Margonato A; Pedrigi C; Chierchia SL
    G Ital Cardiol; 1998 May; 28(5):536-43. PubMed ID: 9646069
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dobutamine 99Tcm-MIBI SPET myocardial perfusion scintigraphy in the prediction of restenosis after percutaneous transluminal coronary angioplasty in patients unable to perform an exercise stress test.
    Elhendy A; Geleijnse ML; Roelandt JR; van Domburg RT; Nierop PR; Bax JJ; Kasprzak JD; el-Said GM; Ibrahim MM; Fioretti PM
    Nucl Med Commun; 1997 Feb; 18(2):122-8. PubMed ID: 9076767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevalence and prognostic value of perfusion defects detected by stress technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography in asymptomatic patients with diabetes mellitus and no known coronary artery disease.
    De Lorenzo A; Lima RS; Siqueira-Filho AG; Pantoja MR
    Am J Cardiol; 2002 Oct; 90(8):827-32. PubMed ID: 12372568
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Tc-99m MIBI myocardial scintigraphy in evaluation of the effect of percutaneous transluminal coronary angioplasty on coronary artery stenosis].
    Peng NJ; Wang SP; Liu RS; Tsay DG; Yeh SH
    Zhonghua Yi Xue Za Zhi (Taipei); 1992 Jan; 49(1):41-7. PubMed ID: 1312384
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of exercise stress technetium 99m sestamibi SPECT imaging in the evaluation of the extent and location of coronary artery disease in patients with an earlier myocardial infarction.
    Elhendy A; Sozzi FB; van Domburg RT; Bax JJ; Geleijnse ML; Valkema R; Krenning EP; Roelandt JR
    J Nucl Cardiol; 2000; 7(5):432-8. PubMed ID: 11083191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial perfusion abnormalities early (12-24 h) after coronary stenting or balloon angioplasty: implications regarding pathophysiology and late clinical outcome.
    Jaffe R; Haim SB; Karkabi B; Front A; Gips S; Weisz G; Khader N; Merdler A; Flugelman MY; Halon DA; Lewis BS
    Cardiology; 2002; 98(1-2):60-6. PubMed ID: 12373049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial and delayed stress phase imaging in a single-injection double-acquisition SPECT. The potential value of early 99mTc-MIBI redistribution in assessment of myocardial perfusion reversibility in patients with coronary artery disease.
    Beiki D; Fallahi B; Mohseni Z; Khalaj A; Fard-Esfahani A; Eftekhari M
    Nuklearmedizin; 2010; 49(1):19-27. PubMed ID: 20162245
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.
    De Boer J; Slart RH; Blanksma PK; Willemsen AT; Jager PL; Paans AM; Vaalburg W; Piers DA
    Nucl Med Commun; 2003 Mar; 24(3):251-7. PubMed ID: 12612465
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of myocardial viability with (99m)Tc-sestamibi -gated SPET images in patients undergoing percutaneous transluminar coronary angioplasty.
    Tzonevska A; Tzvetkov K; Dimitrova M; Piperkova E
    Hell J Nucl Med; 2005; 8(1):48-53. PubMed ID: 15886754
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].
    Leoncini M; Sciagrà R; Bisi G; Santoro GM; Fazzini PF
    G Ital Cardiol; 1993 Feb; 23(2):127-38. PubMed ID: 8491353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term prognostic value of exercise 99mTc-MIBI SPET myocardial perfusion imaging in patients after percutaneous coronary intervention.
    Zhang X; Liu X; He ZX; Shi R; Yang M; Gao R; Chen J; Yang Y; Fang W
    Eur J Nucl Med Mol Imaging; 2004 May; 31(5):655-62. PubMed ID: 14740177
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical events following excimer laser angioplasty or balloon angioplasty for complex coronary lesions: subanalysis of a randomised trial.
    Appelman YE; Piek JJ; Redekop WK; de Feyter PJ; Koolen JJ; David GK; Strikwerda S; Tijssen JG; Serruys PW; van Swijndregt E; van Gemert MJ; Lie KI
    Heart; 1998 Jan; 79(1):34-8. PubMed ID: 9505916
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of myocardial perfusion and function by technetium-99m methoxy isobutyl isonitrile before and after percutaneous transluminal coronary angioplasty. Preliminary results.
    Pace L; Betocchi S; Piscione F; Mangoni di Santo Stefano ML; Chiariello M; Salvatore M
    Clin Nucl Med; 1993 Apr; 18(4):286-90. PubMed ID: 8482024
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.