95 related articles for article (PubMed ID: 11220564)
1. An abdominal active can defibrillator may facilitate a successful generator change when a lead failure is present. Solomon AJ; Moubarak JB; Drood JM; Tracy CM; Karasik PE Europace; 1999 Oct; 1(4):266-9. PubMed ID: 11220564 [TBL] [Abstract][Full Text] [Related]
2. [Estimation of defibrillation threshold using abdominally implanted cardioverter-defibrillator with an additional defibrillation pole in a dual-coil lead endocardial defibrillation system]. Pazdyga A; Lubiński A; Lewicka-Nowak E; Królak T; Kempa M; Zienciuk A; Raczak G Pol Merkur Lekarski; 2007 Feb; 22(128):86-9. PubMed ID: 17598649 [TBL] [Abstract][Full Text] [Related]
3. Effect of an active abdominal pulse generator on defibrillation thresholds with a dual-coil, transvenous ICD lead system. Rashba EJ; Farasat M; Kirk MM; Shorofsky SR; Peters RW; Gold MR J Cardiovasc Electrophysiol; 2006 Jun; 17(6):617-20. PubMed ID: 16836709 [TBL] [Abstract][Full Text] [Related]
4. [Implantable cardioverter/defibrillators with endocardial electrode systems: long-term stability of the defibrillator's effectiveness]. Neuzner J; Pitschner HF; Stöhring R; Reinisch P; Schlepper M Z Kardiol; 1995 Jan; 84(1):44-50. PubMed ID: 7863713 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of a novel ventricular support device with defibrillation capabilities in canine and porcine animal models. Killingsworth CR; Rippy MK; Virmani R; Rollins DL; McGiffin DC; Ideker RE J Cardiovasc Electrophysiol; 2008 Aug; 19(8):851-7. PubMed ID: 18373602 [TBL] [Abstract][Full Text] [Related]
6. Optimization of atrial defibrillation with a dual-coil, active pectoral lead system. Rashba EJ; Shorofsky SR; Peters RW; Gold MR J Cardiovasc Electrophysiol; 2004 Jul; 15(7):790-4. PubMed ID: 15250864 [TBL] [Abstract][Full Text] [Related]
7. The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series. Cooper JA; Latacha MP; Soto GE; Garmany RG; Gleva MJ; Chen J; Faddis MN; Smith TW Pacing Clin Electrophysiol; 2008 Nov; 31(11):1405-10. PubMed ID: 18950297 [TBL] [Abstract][Full Text] [Related]
8. Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements. Schulte B; Sperzel J; Carlsson J; Schwarz T; Ehrlich W; Pitschner HF; Neuzner J Europace; 2001 Jul; 3(3):177-80. PubMed ID: 11467457 [TBL] [Abstract][Full Text] [Related]
9. Epicardial and pleural lead ICD systems in children and adolescents maintain functionality over 5 years. Tomaske M; Prêtre R; Rahn M; Bauersfeld U Europace; 2008 Oct; 10(10):1152-6. PubMed ID: 18701602 [TBL] [Abstract][Full Text] [Related]
10. Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can. Lubiński A; Lewicka-Nowak E; Zienciuk A; Królak T; Kempa M; Pazdyga A; Raczak G; Swiatecka G Kardiol Pol; 2005 Sep; 63(3):234-41; discussion 242-3. PubMed ID: 16180177 [TBL] [Abstract][Full Text] [Related]
11. High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead? Osswald BR; De Simone R; Most S; Tochtermann U; Tanzeem A; Karck M Eur J Cardiothorac Surg; 2009 Mar; 35(3):489-92. PubMed ID: 19144533 [TBL] [Abstract][Full Text] [Related]
12. Salvage of exposed implantable cardiac electrical devices and lead systems with pocket change and local flap coverage. Kolker AR; Redstone JS; Tutela JP Ann Plast Surg; 2007 Jul; 59(1):26-9; discussion 30. PubMed ID: 17589255 [TBL] [Abstract][Full Text] [Related]
13. Cardiac defibrillation therapy for at risk patients with systemic right ventricular dysfunction secondary to atrial redirection surgery for dextro-transposition of the great arteries. Michael KA; Veldtman GR; Paisey JR; Yue AM; Robinson S; Allen S; Sunni NS; Kiesewetter C; Salmon T; Roberts PR; Morgan JM Europace; 2007 May; 9(5):281-4. PubMed ID: 17383987 [TBL] [Abstract][Full Text] [Related]
14. Risk of failure of transvenous implantable cardioverter-defibrillator leads. Borleffs CJ; van Erven L; van Bommel RJ; van der Velde ET; van der Wall EE; Bax JJ; Rosendaal FR; Schalij MJ Circ Arrhythm Electrophysiol; 2009 Aug; 2(4):411-6. PubMed ID: 19808497 [TBL] [Abstract][Full Text] [Related]
15. Equivalent performance of epicardial versus endocardial permanent pacing in children: a single institution and manufacturer experience. Odim J; Suckow B; Saedi B; Laks H; Shannon K Ann Thorac Surg; 2008 Apr; 85(4):1412-6. PubMed ID: 18355537 [TBL] [Abstract][Full Text] [Related]
17. Effect of defibrillation testing on management during implantable cardioverter-defibrillator implantation. Leong-Sit P; Gula LJ; Diamantouros P; Krahn AD; Skanes AC; Yee R; Klein GJ Am Heart J; 2006 Dec; 152(6):1104-8. PubMed ID: 17161062 [TBL] [Abstract][Full Text] [Related]
18. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696 [TBL] [Abstract][Full Text] [Related]
19. Lead interaction: rare cause of oversensing during implantation procedure of implantable cardioverter-defibrillator system. Gardas R; Mlynarski R; Staszak K; Drzewiecka A; Pilat E; Zajac T; Kargul W Pacing Clin Electrophysiol; 2006 Oct; 29(10):1174-5. PubMed ID: 17038149 [TBL] [Abstract][Full Text] [Related]
20. Explantation of implantable defibrillator leads using open heart surgery or percutaneous techniques. Camboni D; Wollmann CG; Löher A; Gradaus R; Scheld HH; Schmid C Ann Thorac Surg; 2008 Jan; 85(1):50-5. PubMed ID: 18154777 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]