581 related articles for article (PubMed ID: 11222977)
1. Scalp electrode impedance, infection risk, and EEG data quality.
Ferree TC; Luu P; Russell GS; Tucker DM
Clin Neurophysiol; 2001 Mar; 112(3):536-44. PubMed ID: 11222977
[TBL] [Abstract][Full Text] [Related]
2. Novel hydrogel-based preparation-free EEG electrode.
Alba NA; Sclabassi RJ; Sun M; Cui XT
IEEE Trans Neural Syst Rehabil Eng; 2010 Aug; 18(4):415-23. PubMed ID: 20423811
[TBL] [Abstract][Full Text] [Related]
3. Does combing the scalp reduce scalp electrode impedances?
Mahajan Y; McArthur G
J Neurosci Methods; 2010 May; 188(2):287-9. PubMed ID: 20211649
[TBL] [Abstract][Full Text] [Related]
4. The effects of electrode impedance on data quality and statistical significance in ERP recordings.
Kappenman ES; Luck SJ
Psychophysiology; 2010 Sep; 47(5):888-904. PubMed ID: 20374541
[TBL] [Abstract][Full Text] [Related]
5. Study of impedance spectra for dry and wet EarEEG electrodes.
Kappel SL; Kidmose P
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3161-4. PubMed ID: 26736963
[TBL] [Abstract][Full Text] [Related]
6. High and dry? Comparing active dry EEG electrodes to active and passive wet electrodes.
Mathewson KE; Harrison TJ; Kizuk SA
Psychophysiology; 2017 Jan; 54(1):74-82. PubMed ID: 28000254
[TBL] [Abstract][Full Text] [Related]
7. Miniaturized electroencephalographic scalp electrode for optimal wearing comfort.
Nikulin VV; Kegeles J; Curio G
Clin Neurophysiol; 2010 Jul; 121(7):1007-14. PubMed ID: 20227914
[TBL] [Abstract][Full Text] [Related]
8. A dry electrode for EEG recording.
Taheri BA; Knight RT; Smith RL
Electroencephalogr Clin Neurophysiol; 1994 May; 90(5):376-83. PubMed ID: 7514984
[TBL] [Abstract][Full Text] [Related]
9. The Dependence of Electrode Impedance on the Number of Performed EEG Examinations.
Górecka J; Makiewicz P
Sensors (Basel); 2019 Jun; 19(11):. PubMed ID: 31181738
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of an easy, standardized and clinically practical method (SurePrep) for the preparation of electrode-skin contact in neurophysiological recordings.
Stjerna S; Alatalo P; Mäki J; Vanhatalo S
Physiol Meas; 2010 Jul; 31(7):889-901. PubMed ID: 20505217
[TBL] [Abstract][Full Text] [Related]
11. Novel Multipin Electrode Cap System for Dry Electroencephalography.
Fiedler P; Pedrosa P; Griebel S; Fonseca C; Vaz F; Supriyanto E; Zanow F; Haueisen J
Brain Topogr; 2015 Sep; 28(5):647-656. PubMed ID: 25998854
[TBL] [Abstract][Full Text] [Related]
12. In-service characterization of a polymer wick-based quasi-dry electrode for rapid pasteless electroencephalography.
Pedrosa P; Fiedler P; Pestana V; Vasconcelos B; Gaspar H; Amaral MH; Freitas D; Haueisen J; Nóbrega JM; Fonseca C
Biomed Tech (Berl); 2018 Jul; 63(4):349-359. PubMed ID: 28467306
[TBL] [Abstract][Full Text] [Related]
13. Electrode scalp impedance differences between electroencephalography machines in healthy dogs.
Luca J; Hazenfratz M; Monteith G; Sanchez A; Gaitero L; James F
Can J Vet Res; 2021 Oct; 85(4):309-311. PubMed ID: 34602736
[TBL] [Abstract][Full Text] [Related]
14. A new EEG recording system for passive dry electrodes.
Gargiulo G; Calvo RA; Bifulco P; Cesarelli M; Jin C; Mohamed A; van Schaik A
Clin Neurophysiol; 2010 May; 121(5):686-93. PubMed ID: 20097606
[TBL] [Abstract][Full Text] [Related]
15. Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.
Liao LD; Wang IJ; Chen SF; Chang JY; Lin CT
Sensors (Basel); 2011; 11(6):5819-34. PubMed ID: 22163929
[TBL] [Abstract][Full Text] [Related]
16. Design Principles and Dynamic Front End Reconfiguration for Low Noise EEG Acquisition With Finger Based Dry Electrodes.
Nathan V; Jafari R
IEEE Trans Biomed Circuits Syst; 2015 Oct; 9(5):631-40. PubMed ID: 26462239
[TBL] [Abstract][Full Text] [Related]
17. Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings.
Benovitski YB; Lai A; McGowan CC; Burns O; Maxim V; Nayagam DAX; Millard R; Rathbone GD; le Chevoir MA; Williams RA; Grayden DB; May CN; Murphy M; D'Souza WJ; Cook MJ; Williams CE
Epilepsy Res; 2017 Sep; 135():29-37. PubMed ID: 28618377
[TBL] [Abstract][Full Text] [Related]
18. Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation.
Chi YM; Cauwenberghs G
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4218-21. PubMed ID: 19964104
[TBL] [Abstract][Full Text] [Related]
19. [Verification of skin paste electrodes used in wireless polysomnography].
Ma YD; Huang D; Chen YF; Jiang HY; Liu JH; Sun HQ; Li ZH
Beijing Da Xue Xue Bao Yi Xue Ban; 2018 Apr; 50(2):358-363. PubMed ID: 29643540
[TBL] [Abstract][Full Text] [Related]
20. Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording.
Greischar LL; Burghy CA; van Reekum CM; Jackson DC; Pizzagalli DA; Mueller C; Davidson RJ
Clin Neurophysiol; 2004 Mar; 115(3):710-20. PubMed ID: 15036067
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]