These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 11225826)

  • 21. A comparative study on fabrication of Mn2+ selective polymeric membrane electrode and coated graphite electrode.
    Singh AK; Bandi KR; Upadhyay A; Jain AK
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):626-33. PubMed ID: 25427466
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A novel poly(vinyl chloride) matrix membrane sensor for batch and flow-injection determinations of thiocyanate, cyanide and some metal ions.
    Hassan SS; Badr IH; Kamel AH; Mohamed MS
    Anal Sci; 2009 Jul; 25(7):911-7. PubMed ID: 19609032
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.
    Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode.
    Benco JS; Nienaber HA; McGimpsey WG
    Anal Chem; 2003 Jan; 75(1):152-6. PubMed ID: 12530832
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
    Kormalı Ertürün HE; Demirel Özel A; Sayın S; Yılmaz M; Kılıç E
    Talanta; 2015 Jan; 132():669-75. PubMed ID: 25476362
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Functionalized β-cyclodextrin based potentiometric sensor for naproxen determination.
    Lenik J; Łyszczek R
    Mater Sci Eng C Mater Biol Appl; 2016 Apr; 61():149-57. PubMed ID: 26838835
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Zirconium ion selective electrode based on bis(diphenylphosphino) ferrocene incorporated in a poly(vinyl chloride) matrix.
    Gholivand MB; Babakhanian A; Joshaghani M
    Anal Chim Acta; 2007 Feb; 584(2):302-7. PubMed ID: 17386619
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new potentiometric electrode incorporating functionalized β-cyclodextrins for diclofenac determination.
    Lenik J
    Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():109-16. PubMed ID: 25491808
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ribonucleic acid as a novel ionophore for potentiometric membrane sensors of some transition metal ions.
    Hassan SS; Mahmoud WH; Othman AH
    Talanta; 1998 Oct; 47(2):377-85. PubMed ID: 18967339
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Construction of a new selective coated disk electrode for Ag (I) based on modified polypyrrole-carbon nanotubes composite with new lariat ether.
    Abbaspour A; Tashkhourian J; Ahmadpour S; Mirahmadi E; Sharghi H; Khalifeh R; Shahriyari MR
    Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():326-33. PubMed ID: 24268265
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone.
    Mahajan RK; Kaur I; Lobana TS
    Talanta; 2003 Jan; 59(1):101-5. PubMed ID: 18968889
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Tetrabenzyl pyrophosphate as a new class of neutral carrier responsive to lead ion.
    Xu D; Katsu T
    Talanta; 2000 Feb; 51(2):365-71. PubMed ID: 18967868
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A selective potentiometric copper (II) ion sensor based on the functionalized ZnO nanorods.
    Khun K; Ibupoto ZH; Liu X; Nur O; Willander M; Danielsson B
    J Nanosci Nanotechnol; 2014 Sep; 14(9):6723-31. PubMed ID: 25924323
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
    Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
    Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples.
    Gupta VK; Singh AK; Gupta B
    Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212
    [TBL] [Abstract][Full Text] [Related]  

  • 36. One-component room temperature vulcanizing-type silicone rubber-based calcium-selective electrodes.
    Oh BK; Kim CY; Lee HJ; Rho KL; Cha GS; Nam H
    Anal Chem; 1996 Feb; 68(3):503-8. PubMed ID: 21619086
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form.
    Ragab MT; Abd El-Rahman MK; Ramadan NK; El-Ragehy NA; El-Zeany BA
    Talanta; 2015 Jun; 138():28-35. PubMed ID: 25863367
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II) Ions.
    Rizk NM; Abbas SS; Hamza SM; Abd El-Karem YM
    Sensors (Basel); 2009; 9(3):1860-75. PubMed ID: 22573991
    [TBL] [Abstract][Full Text] [Related]  

  • 39. New cesium ion-selective electrodes based on anilino-(1,3-dioxo-2-indanylidene) acetonitrile derivatives.
    Saleh MB
    Talanta; 1998 Aug; 46(5):885-95. PubMed ID: 18967210
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Copper(II)-selective electrode using 2,2'-dithiodianiline as neutral carrier.
    Gholivand MB; Nozari N
    Talanta; 2001 May; 54(4):597-602. PubMed ID: 18968282
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.