These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 11225942)
1. Detection of ventricular fibrillation in implantable defibrillators with automatic gain control amplifiers: effects of programming sensitivity. Schulte B; Sperzel J; Schwarz T; Pitschner HF; Strupp G; Neuzner J Europace; 2000 Apr; 2(2):160-2. PubMed ID: 11225942 [TBL] [Abstract][Full Text] [Related]
2. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related]
3. Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements. Schulte B; Sperzel J; Carlsson J; Schwarz T; Ehrlich W; Pitschner HF; Neuzner J Europace; 2001 Jul; 3(3):177-80. PubMed ID: 11467457 [TBL] [Abstract][Full Text] [Related]
4. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site. Fetter JG; Benditt DG; Stanton MS J Am Coll Cardiol; 1996 Aug; 28(2):423-7. PubMed ID: 8800120 [TBL] [Abstract][Full Text] [Related]
5. Electrocautery-induced ventricular tachycardia and fibrillation during device implantation and explantation. Lo R; Mitrache A; Quan W; Cohen TJ J Invasive Cardiol; 2007 Jan; 19(1):12-5. PubMed ID: 17297178 [TBL] [Abstract][Full Text] [Related]
6. In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators. Chiladakis JA; Davlouros P; Agelopoulos G; Manolis AS Eur Heart J; 2001 Aug; 22(15):1337-42. PubMed ID: 11465966 [TBL] [Abstract][Full Text] [Related]
7. True bipolar defibrillator leads have increased sensing latency and threshold compared with the integrated bipolar configuration. Frain BH; Ellison KE; Michaud GF; Koo CH; Buxton AE; Kirk MM J Cardiovasc Electrophysiol; 2007 Feb; 18(2):192-5. PubMed ID: 17239139 [TBL] [Abstract][Full Text] [Related]
9. Transvenous pectoral implantation of single lead implantable cardioverter defibrillator. Wang F; Hua W; Chen X Chin Med J (Engl); 1999 Jan; 112(1):22-4. PubMed ID: 11593633 [TBL] [Abstract][Full Text] [Related]
10. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators. Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458 [TBL] [Abstract][Full Text] [Related]