These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 1122627)

  • 21. [Determination of urinary total proteins and some protein fractions].
    Tarantino M; Marchi S
    Quad Sclavo Diagn; 1975 Mar; 11(1):82-102. PubMed ID: 50609
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Development of gel filtration and specific analyses of urinary carbohydrate and protein material.
    White CA; Kennedy JF
    Clin Chim Acta; 1979 Jul; 95(2):369-80. PubMed ID: 527226
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A CONTINUOUS, AUTOMATIC METHOD FOR THE STUDY OF RATE OF HYDROLYSIS OF PEPTIDES AND AMIDES.
    LENARD J; JOHNSON SL; HYMAN RW; HESS GP
    Anal Biochem; 1965 Apr; 11():30-41. PubMed ID: 14328643
    [No Abstract]   [Full Text] [Related]  

  • 24. Assessment of five quantitative methods for determination of total proteins in urine.
    Lizana J; Brito M; Davis MR
    Clin Biochem; 1977 Apr; 10(2):89-93. PubMed ID: 862182
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of the Vickers D300 for routine analysis of urea, bilirubin, total protein and albumin in plasma.
    Brown AJ; Baster P; Bell JL
    Clin Chim Acta; 1973 Aug; 47(1):51-8. PubMed ID: 4127043
    [No Abstract]   [Full Text] [Related]  

  • 26. ON THE COLORIMETRIC BIURET METHOD OF PROTEIN DETERMINATION.
    PARVIN R; PANDE SV; VENKITASUBRAMANIAN TA
    Anal Biochem; 1965 Aug; 12():219-29. PubMed ID: 14340012
    [No Abstract]   [Full Text] [Related]  

  • 27. An assessment of the suitability of bromocresol green for the determination of serum albumin.
    Webster D; Bignell AH; Attwood EC
    Clin Chim Acta; 1974 May; 53(1):101-8. PubMed ID: 4210386
    [No Abstract]   [Full Text] [Related]  

  • 28. STUDIES ON THE BIURET-HYDROLYZING ENZYME FROM MYCOBACTERIUM RANAE.
    NISHIHARA H; SHOJI K; HORI M
    Biken J; 1965 Apr; 8():23-34. PubMed ID: 14340035
    [No Abstract]   [Full Text] [Related]  

  • 29. Urinary protein determination using Coomassie Brilliant Blue in the presence of sodium dodecyl sulphate.
    Perini JM; Mizon C; Dehon B; Fialdes P; Lefebvre I; Mizon J; Roussel P
    Clin Chim Acta; 1984 Nov; 143(3):321-8. PubMed ID: 6499227
    [No Abstract]   [Full Text] [Related]  

  • 30. Automatic analysis of amino acid and peptide with 1-fluoro-2,4-dinitrobenzene.
    Satake K; Matsuo A; Take T
    J Biochem; 1965 Jul; 58(1):90-7. PubMed ID: 5857105
    [No Abstract]   [Full Text] [Related]  

  • 31. [Rapid determination of total blood proteins and serum albumin using automatic instrumentation].
    Ferrari G; Galmarini S
    Quad Sclavo Diagn; 1984 Jun; 20(2):155-62. PubMed ID: 6528015
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of an improved Coomassie dye binding method for urinary protein assay.
    Macart M; Gerbaut L
    Clin Chim Acta; 1984 Aug; 141(1):77-84. PubMed ID: 6467623
    [No Abstract]   [Full Text] [Related]  

  • 33. Measurement of serum albumin on the technicon SMA 12-60 autoanalyzer by the bromcresol green method.
    Gyure WL; Raisys VA
    Clin Biochem; 1973 Dec; 6(4):229-36. PubMed ID: 4777722
    [No Abstract]   [Full Text] [Related]  

  • 34. [Quantitative determination of total urinary protein utilizing the principle of Coomassie Brilliant Blue G250 binding to protein (author's transl)].
    Thomas L; Winckelmann M; Michaelis HC; Walb D
    J Clin Chem Clin Biochem; 1981 Apr; 19(4):203-8. PubMed ID: 7241057
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Albumin determination by autoanalyser (BCG method)].
    Tanaka F; Nishiki M; Furukawa I; Hayashi C
    Rinsho Byori; 1971 Aug; 19():Suppl:404. PubMed ID: 5168091
    [No Abstract]   [Full Text] [Related]  

  • 36. Albumin-based or albumin-linked calibrators cause a positive bias in serum proteins assayed by the biuret method.
    Chromý V; Sváchová L; Novosád L; Jarkovský J; Sedlák P; Horák P; Dobrovolná H; Hlavácová B
    Clin Chem Lab Med; 2009; 47(1):91-101. PubMed ID: 19117409
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An improved automated Biuret method for the determination of microgram protein concentrations.
    Honn KV; Chavin W
    Anal Biochem; 1975 Sep; 68(1):230-5. PubMed ID: 1190437
    [No Abstract]   [Full Text] [Related]  

  • 38. [Changes and precisions applied to the automatic determination of serum albumin by methylorange].
    Nyssen M; Dorche J
    Ann Biol Clin (Paris); 1966; 24(7):851-61. PubMed ID: 5967636
    [No Abstract]   [Full Text] [Related]  

  • 39. Automated Lowry method for microdetermination of protein in samples and effluents containing nonionic detergents.
    Kusov YY; Kalinchuk NA
    Anal Biochem; 1978 Jul; 88(1):256-62. PubMed ID: 697000
    [No Abstract]   [Full Text] [Related]  

  • 40. [Comparative evaluation of the methods of prognosis of hemolytic disease of newborn].
    Puichenok NA; Nikitina II
    Vopr Okhr Materin Det; 1978 Jan; 23(1):29-31. PubMed ID: 564572
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.