These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 11227971)

  • 21. Defibrillation efficacy and pain perception of two biphasic waveforms for internal cardioversion of atrial fibrillation.
    Jung J; Hahn SJ; Heisel A; Buob A; Schubert BD; Siaplaouras S
    J Cardiovasc Electrophysiol; 2003 Aug; 14(8):837-40. PubMed ID: 12890046
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation.
    Walcott GP; Walker RG; Cates AW; Krassowska W; Smith WM; Ideker RE
    J Cardiovasc Electrophysiol; 1995 Sep; 6(9):737-50. PubMed ID: 8556194
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biphasic waveforms for ventricular defibrillation: optimization of total pulse and second phase durations.
    Matula MH; Brooks MJ; Pan Q; Pless BD; Province RA; Echt DS
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2154-62. PubMed ID: 9309738
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Smaller capacitors improve the biphasic waveform.
    Rist K; Tchou PJ; Mowrey K; Kroll MW; Brewer JE
    J Cardiovasc Electrophysiol; 1994 Sep; 5(9):771-6. PubMed ID: 7827716
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of changing capacitors between phases of a biphasic defibrillation shock.
    Walcott GP; Rollins DL; Smith WM; Ideker RE
    Pacing Clin Electrophysiol; 1996 Jun; 19(6):945-54. PubMed ID: 8774825
    [TBL] [Abstract][Full Text] [Related]  

  • 26. External exponential biphasic versus monophasic shock waveform: efficacy in ventricular fibrillation of longer duration.
    Yamanouchi Y; Brewer JE; Donohoo AM; Mowrey KA; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 1999 Oct; 22(10):1481-7. PubMed ID: 10588150
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stepped defibrillation waveform is substantially more efficient than the 50/50% tilt biphasic.
    Seidl K; Denman RA; Moulder JC; Mouchawar G; Stoeppler C; Becker T; Weise U; Anskey EJ; Burnett HE; Kroll MW
    Heart Rhythm; 2006 Dec; 3(12):1406-11. PubMed ID: 17161781
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The strength-duration relationship of monophasic waveforms with varying capacitance sizes in external defibrillation.
    Yamanouchi Y; Mowrey K; Mazgalev TN; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 2003 Dec; 26(12):2213-8. PubMed ID: 14675002
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Benefit of millisecond waveform durations for patients with high defibrillation thresholds.
    Denman RA; Umesan C; Martin PT; Forbes RN; Kroll MW; Anskey EJ; Burnett HE
    Heart Rhythm; 2006 May; 3(5):536-41. PubMed ID: 16648057
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of defibrillation efficacy using biphasic waveforms delivered from various capacitances/pulse widths.
    Lin JH; Stotts LJ; Rosborough JP; Frederick H
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 2):158-62. PubMed ID: 9121981
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of single-biphasic versus sequential-biphasic shocks on defibrillation threshold in pigs.
    Csanadi Z; Jones DL; Wood GK; Klein GJ
    Pacing Clin Electrophysiol; 1997 Jun; 20(6):1606-12. PubMed ID: 9227756
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator.
    Brugada J; Herse B; Sandsted B; Michel U; Schubert BD; Hahn SJ
    Europace; 2001 Oct; 3(4):278-84. PubMed ID: 11678385
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A prospective randomized comparison of defibrillation efficacy of truncated pulses and damped sine wave pulses in humans.
    Bardy GH; Zaghi H; Gartman D; Poole JE; Kudenchuk PK; Dolack GL; Johnson G; Troutman C
    J Cardiovasc Electrophysiol; 1994 Sep; 5(9):725-30. PubMed ID: 7827711
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimizing defibrillation through improved waveforms.
    Block M; Breithardt G
    Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):526-38. PubMed ID: 7777417
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A prospective, randomized, comparison in patients between a pectoral unipolar defibrillation system and that using an additional inferior vena cava electrode.
    Favale S; Dicandia CD; Tunzi P; Rizzon P
    Pacing Clin Electrophysiol; 1999 Aug; 22(8):1140-5. PubMed ID: 10461288
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of an active abdominal pulse generator on defibrillation thresholds with a dual-coil, transvenous ICD lead system.
    Rashba EJ; Farasat M; Kirk MM; Shorofsky SR; Peters RW; Gold MR
    J Cardiovasc Electrophysiol; 2006 Jun; 17(6):617-20. PubMed ID: 16836709
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system.
    Huang J; KenKnight BH; Walcott GP; Walker RG; Smith WM; Ideker RE
    J Cardiovasc Electrophysiol; 1997 Feb; 8(2):161-71. PubMed ID: 9048247
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimal small-capacitor biphasic waveform for external defibrillation: influence of phase-1 tilt and phase-2 voltage.
    Yamanouchi Y; Brewer JE; Mowrey KA; Donohoo AM; Wilkoff BL; Tchou PJ
    Circulation; 1998 Dec; 98(22):2487-93. PubMed ID: 9832496
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Internal defibrillation with smaller capacitors: a prospective randomized cross-over comparison of defibrillation efficacy obtained with 90-microF and 125-microF capacitors in humans.
    Block M; Hammel D; Böcker D; Borggrefe M; Seifert T; Fastenrath C; Scheld HH; Breithardt G
    J Cardiovasc Electrophysiol; 1995 May; 6(5):333-42. PubMed ID: 7551301
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system.
    Yamanouchi Y; Mowrey KA; Nadzam GR; Hills DG; Kroll MW; Brewer JE; Donohoo AM; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2911-6. PubMed ID: 9455750
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.