108 related articles for article (PubMed ID: 11229057)
1. Effect of stent on radiation dosimetry in an in-stent restenosis model.
Fan P; Chiu-Tsao ST; Patel NS; Shih A; Ravi K; Sherman W; Tsao HS; Pisch J; Harrison LB
Cardiovasc Radiat Med; 2000; 2(1):18-25. PubMed ID: 11229057
[TBL] [Abstract][Full Text] [Related]
2. Effect of stent on radiation dosimetry in an in-stent restenosis model.
Fan P; Chiu-Tsao S; Patel NS; Shih A; Ravi K; Sherman W; Tsao H; Pisch J; Harrison LB
Cardiovasc Radiat Med; 2001 Jan; 2(1):18-25. PubMed ID: 11068251
[TBL] [Abstract][Full Text] [Related]
3. Dosimetry study for beta-radiation treatment of in-stent restenosis.
Chu CH; Hsieh BT; Chen IJ; Chen WL; Lin UT
Radiat Prot Dosimetry; 2009 Feb; 134(1):49-54. PubMed ID: 19376885
[TBL] [Abstract][Full Text] [Related]
4. Dose perturbation caused by stents: experiments with a model 90Sr/90Y source.
Wilczek K; Petelenz B; Strzała A; Marczewska B; Traczyk M; Poloński L
Cardiovasc Intervent Radiol; 2007; 30(5):981-91. PubMed ID: 17710473
[TBL] [Abstract][Full Text] [Related]
5. Improving patient-specific dosimetry for intravascular brachytherapy.
Li XA; O'Neill M; Suntharalingam M
Brachytherapy; 2005; 4(4):291-7. PubMed ID: 16344260
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric penumbra effects in catheter-based intravascular brachytherapy using a centered photon or beta line source.
Yue N; Nath R; Roberts K
Cardiovasc Radiat Med; 2000; 2(1):32-8. PubMed ID: 11229060
[TBL] [Abstract][Full Text] [Related]
7. Dose effects of stents in intravascular brachytherapy for in-stent restenosis: a Monte Carlo calculation.
Li XA
Int J Radiat Oncol Biol Phys; 2003 Mar; 55(3):842-8. PubMed ID: 12573772
[TBL] [Abstract][Full Text] [Related]
8. Shielding effects of metallic encapsulations and radiographic contrast agents for catheter-based intravascular brachytherapy.
Nath R; Yue N
Cardiovasc Radiat Med; 2001; 2(2):93-103. PubMed ID: 11340013
[TBL] [Abstract][Full Text] [Related]
9. Effects of vessel curvature on dose distributions in catheter-based intravascular brachytherapy for various radionuclides.
Yue N; Roberts K; Nath R
Cardiovasc Radiat Med; 2004; 5(3):142-50. PubMed ID: 15721850
[TBL] [Abstract][Full Text] [Related]
10. Effects of off-centering on dose uniformity along and around blood vessels undergoing catheter-based intravascular brachytherapy.
Nath R; Yue N
Cardiovasc Radiat Med; 2004; 5(2):88-96. PubMed ID: 15464946
[TBL] [Abstract][Full Text] [Related]
11. Response to radiation therapy in animal restenosis models.
Waksman R
Semin Interv Cardiol; 1997 Jun; 2(2):95-101. PubMed ID: 9546998
[TBL] [Abstract][Full Text] [Related]
12. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
[TBL] [Abstract][Full Text] [Related]
13. The impact of stent design and delivery upon the long-term efficacy of radioisotope stents.
Fischell TA; Hehrlein C; Fischell RE; Fischell DR
J Invasive Cardiol; 2000 Mar; 12(3):162-7. PubMed ID: 10731287
[TBL] [Abstract][Full Text] [Related]
14. Endovascular brachytherapy in coronary arteries: the Rotterdam experience.
Coen VL; Knook AH; Wardeh AJ; van der Giessen WJ; De Pan C; Sipkema D; Marijnissen JP; Sabaté M; den Boer A; Serruys PW; Levendag PC
Cardiovasc Radiat Med; 2000; 2(1):42-50. PubMed ID: 11229062
[TBL] [Abstract][Full Text] [Related]
15. Beta versus gamma for catheter-based intravascular brachytherapy: dosimetric perspectives in the presence of metallic stents and calcified plaques.
Li XA; Wang R; Yu C; Suntharalingam M
Int J Radiat Oncol Biol Phys; 2000 Mar; 46(4):1043-9. PubMed ID: 10705028
[TBL] [Abstract][Full Text] [Related]
16. Irradiation and stenting.
Weinberger J
Semin Interv Cardiol; 1997 Jun; 2(2):103-8. PubMed ID: 9546989
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric penumbra effects in catheter-based intravascular brachytherapy using a centered photon or beta line source.
Yue N; Nath R; Roberts K
Cardiovasc Radiat Med; 2001 Jan; 2(1):32-38. PubMed ID: 11068253
[TBL] [Abstract][Full Text] [Related]
18. Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements.
Sureka CS; Sunny CS; Subbaiah KV; Aruna P; Ganesan S
Phys Med Biol; 2007 Jan; 52(2):525-37. PubMed ID: 17202631
[TBL] [Abstract][Full Text] [Related]
19. Advantages and limitations of radioactive stents.
Hehrlein C; Kübler W
Semin Interv Cardiol; 1997 Jun; 2(2):109-13. PubMed ID: 9546990
[TBL] [Abstract][Full Text] [Related]
20. Esophageal cancer patients undergoing external beam radiation after placement of self-expandable metal stents: is there a risk of radiation dose enhancement?
Chen YK; Schefter TE; Newman F
Gastrointest Endosc; 2011 Jun; 73(6):1109-14. PubMed ID: 21628012
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]