These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

60 related articles for article (PubMed ID: 11232704)

  • 1. Can one predict when ultrasound will be useful with percutaneous liver biopsy?
    Ahmad M; Riley TR
    Am J Gastroenterol; 2001 Feb; 96(2):547-9. PubMed ID: 11232704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. How often does ultrasound marking change the liver biopsy site?
    Riley TR
    Am J Gastroenterol; 1999 Nov; 94(11):3320-2. PubMed ID: 10566737
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blind percutaneous liver biopsy in infants and children: Comparison of safety and efficacy of percussion technique and ultrasound assisted technique.
    Mogahed EA; Mansy YA; Al Hawi Y; El-Sayed R; El-Raziky M; El-Karaksy H
    Arab J Gastroenterol; 2016 Dec; 17(4):168-175. PubMed ID: 27914885
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Incidence of ultrasound detectable liver hematomas after ultrasound controlled fine needle puncture with the 0.95 mm cutting biopsy cannula in comparison with percutaneous liver biopsy with the 1.4 mm Menghini needle].
    Glaser J; Mann O; von Eiff M; Pfahlberg A; Pausch J
    Med Klin (Munich); 1995 Mar; 90(3):131-3. PubMed ID: 7723713
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous biopsy in diffuse liver disease: increasing diagnostic yield and decreasing complication rate by routine ultrasound assessment of puncture site.
    Caturelli E; Giacobbe A; Facciorusso D; Bisceglia M; Villani MR; Siena DA; Fusilli S; Squillante MM; Andriulli A
    Am J Gastroenterol; 1996 Jul; 91(7):1318-21. PubMed ID: 8677986
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prospective study of the incidence of ultrasound-detected hepatic hematomas due to percutaneous Menghini needle liver biopsy and laparoscopy-guided Silverman needle biopsy.
    Glaser J; Mann O; Siegmüller M; Pausch J
    Ital J Gastroenterol; 1994 Sep; 26(7):338-41. PubMed ID: 7812026
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy.
    Lindor KD; Bru C; Jorgensen RA; Rakela J; Bordas JM; Gross JB; Rodes J; McGill DB; Reading CC; James EM; Charboneau JW; Ludwig J; Batts KP; Zinsmeister AR
    Hepatology; 1996 May; 23(5):1079-83. PubMed ID: 8621137
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Complications of blind versus ultrasound-guided percutaneous liver biopsy in children.
    Honar N; Jooya P; Haghighat M; Imanieh MH; Dehghani SM; Zahmatkeshan M; Javaherizadeh H
    Arab J Gastroenterol; 2015; 16(3-4):90-3. PubMed ID: 26526508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound-guided liver biopsy: accuracy, safety and sonographic findings.
    Pongchairerks P
    J Med Assoc Thai; 1993 Nov; 76(11):597-600. PubMed ID: 7964233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results.
    Hakime A; Deschamps F; De Carvalho EG; Barah A; Auperin A; De Baere T
    Cardiovasc Intervent Radiol; 2012 Aug; 35(4):898-905. PubMed ID: 21947580
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Prospective study of the incidence of ultrasound detectable liver hematomas after laparoscopically controlled liver puncture with the Silverman needle].
    Glaser J; Mann O; Siegmüller M; Pausch J
    Med Klin (Munich); 1994 Jul; 89(7):349-50. PubMed ID: 7935222
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Liver biopsy complications and routine ultrasound.
    Stotland BR; Lichtenstein GR
    Am J Gastroenterol; 1996 Jul; 91(7):1295-6. PubMed ID: 8677980
    [No Abstract]   [Full Text] [Related]  

  • 13. Colour doppler sonography guided percutaneous fine-needle biopsy of the liver.
    Polaków J; Ladny JR; Dziecioł J; Puchalski Z; Walecki J
    Rocz Akad Med Bialymst; 1997; 42(1):241-4. PubMed ID: 9581487
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound-guided plugged percutaneous biopsy of solid organs in patients with bleeding tendencies.
    Tsang WK; Luk WH; Lo A
    Hong Kong Med J; 2014 Apr; 20(2):107-12. PubMed ID: 23878203
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Sonographically assisted liver biopsy--replacement for blind needle biopsy?].
    Greiner L; Franken FH
    Dtsch Med Wochenschr; 1983 Mar; 108(10):368-72. PubMed ID: 6218980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of contrast enhanced ultrasound guidance in percutaneous biopsies of liver tumors.
    Sparchez Z; Radu P; Zaharia T; Kacso G; Grigorescu I; Botis G; Badea R
    J Gastrointestin Liver Dis; 2011 Jun; 20(2):191-6. PubMed ID: 21725517
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [CT-guided percutaneous biopsies for the classification of focal liver lesions: a comparison between 14 G and 18 G puncture biopsy needles].
    Haage P; Piroth W; Staatz G; Adam G; Günther RW
    Rofo; 1999 Jul; 171(1):44-8. PubMed ID: 10464504
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Liver transplant biopsies with a biopsy gun.
    Chezmar JL; Keith LL; Nelson RC; Plaire JC; Hertzler GL; Bernardino ME
    Radiology; 1991 May; 179(2):447-8. PubMed ID: 2014290
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Transjugular liver biopsy with a modified Tru-Cut system: a retrospective study of its successes and complications].
    von Falkenhausen M; Strunk H; Fischer HP; Schild HH
    Rofo; 1999 Apr; 170(4):394-6. PubMed ID: 10341800
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Ultrasound-guided biopsy in focal lesions of the liver. Report on an automated biopsy system].
    Soyer P; Debroucker F; Lacheheb D; Barge J; Levesque M
    J Radiol; 1993 Apr; 74(4):215-9. PubMed ID: 8505717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.