These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 11236883)

  • 1. Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation.
    Kyriacou PA; Moye AR; Choi DM; Langford RM; Jones DP
    Physiol Meas; 2001 Feb; 22(1):223-32. PubMed ID: 11236883
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
    Kyriacou PA; Powell S; Langford RM; Jones DP
    Physiol Meas; 2002 Aug; 23(3):533-45. PubMed ID: 12214761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients.
    Kyriacou PA; Moye AR; Gregg A; Choi DM; Langford RM; Jones DP
    Med Biol Eng Comput; 1999 Sep; 37(5):639-43. PubMed ID: 10723903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
    Pal SK; Kyriacou PA; Kumaran S; Fadheel S; Emamdee R; Langford RM; Jones DP
    Burns; 2005 May; 31(3):337-41. PubMed ID: 15774290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.
    Kyriacou PA; Powell SL; Jones DP; Langford RM
    Anaesthesia; 2003 May; 58(5):422-7. PubMed ID: 12693996
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Esophageal pulse oximetry utilizing reflectance photoplethysmography.
    Kyriacou PA; Powell S; Langford RM; Jones DP
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1360-8. PubMed ID: 12450366
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulse oximetry in the oesophagus.
    Kyriacou PA
    Physiol Meas; 2006 Jan; 27(1):R1-35. PubMed ID: 16365505
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation.
    Budidha K; Kyriacou PA
    Physiol Meas; 2014 Feb; 35(2):111-28. PubMed ID: 24399082
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Devepopment of an optical probe to investigate the suitability of measuring photoplethysmographs and blood oxygen saturation from the human auditory canal.
    Budidha K; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1736-9. PubMed ID: 24110042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.
    Shafique M; Kyriacou PA; Pal SK
    Med Biol Eng Comput; 2012 Jun; 50(6):575-83. PubMed ID: 22555629
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Esophageal SpO2 measurements from a pediatric burns-patient: a case study.
    Kyriacou PA; May JM; Petros AJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1732-5. PubMed ID: 24110041
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion.
    Abay TY; Kyriacou PA
    IEEE Trans Biomed Eng; 2015 Sep; 62(9):2187-95. PubMed ID: 25838515
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    J Clin Monit Comput; 2011 Aug; 25(4):245-55. PubMed ID: 21953382
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Free flap pulse oximetry utilizing reflectance photoplethysmography.
    Zaman T; Kyriacou PA; Pal SK
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4046-9. PubMed ID: 24110620
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry.
    Shafqat K; Jones DP; Langford RM; Kyriacou PA
    Med Biol Eng Comput; 2006 Aug; 44(8):729-37. PubMed ID: 16937215
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe.
    Abdollahi Z; Phillips JP; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1728-31. PubMed ID: 24110040
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Direct pulse oximetry within the esophagus, on the surface of abdominal viscera, and on free flaps.
    Kyriacou PA
    Anesth Analg; 2013 Oct; 117(4):824-833. PubMed ID: 24023025
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Novel Photoplethysmography Sensor for Vital Signs Monitoring from the Human Trachea.
    May JM; Phillips JP; Fitchat T; Ramaswamy S; Snidvongs S; Kyriacou PA
    Biosensors (Basel); 2019 Oct; 9(4):. PubMed ID: 31581652
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.