These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 11244353)

  • 21. [Experience in using silicone rubber in the surgery of retinal detachment].
    Indeĭkin EN; Tolstenko VP; Gorbat'ko AM
    Oftalmol Zh; 1982; 37(3):153-4. PubMed ID: 7133584
    [No Abstract]   [Full Text] [Related]  

  • 22. Complications of emulsified silicone oil after retinal detachment repair.
    Miller JB; Papakostas TD; Vavvas DG
    Semin Ophthalmol; 2014; 29(5-6):312-8. PubMed ID: 25325856
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Outcomes of complex retinal detachment repair using 1000- vs 5000-centistoke silicone oil.
    Scott IU; Flynn HW; Murray TG; Smiddy WE; Davis JL; Feuer WJ
    Arch Ophthalmol; 2005 Apr; 123(4):473-8. PubMed ID: 15824219
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intraocular intrusion of a scleral sponge implant.
    Unlü N; Kocaoglan H; Acar MA; Aslan BS; Duman S
    Ophthalmic Surg Lasers Imaging; 2003; 34(3):223-5. PubMed ID: 12757100
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Surgical results in retinal detachment and complications in using different filling materials].
    Koval' EB; Mileĭko EG; Rusetskaia NS; Lemziakov GG; Tret'iak TP
    Oftalmol Zh; 1982; 37(3):151-2. PubMed ID: 7133583
    [No Abstract]   [Full Text] [Related]  

  • 26. Retinal redetachment after silicone oil removal in proliferative vitreoretinopathy: a prognostic factor analysis.
    Mondal S; Hussain N; Natarajan S
    Am J Ophthalmol; 2008 Jul; 146(1):145; author reply 145. PubMed ID: 18573359
    [No Abstract]   [Full Text] [Related]  

  • 27. [Cataract after silicone oil tamponade and its surgical treatment].
    Zhang S; Gao R; Xie H
    Zhonghua Yan Ke Za Zhi; 1995 Nov; 31(6):430-2. PubMed ID: 8762570
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An unusual complication of retinal reattachment surgery.
    Ozertürk Y; Bardak Y; Durmus M
    Ophthalmic Surg Lasers; 1999 Jun; 30(6):483-4. PubMed ID: 10392738
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Conventional buckling surgery or primary vitrectomy with silicone oil tamponade in rhegmatogenous retinal detachment with multiple breaks.
    Afrashi F; Erakgun T; Akkin C; Kaskaloglu M; Mentes J
    Graefes Arch Clin Exp Ophthalmol; 2004 Apr; 242(4):295-300. PubMed ID: 14714188
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Functional and anatomic results with intra-ocular tamponade in retinal detachment surgery].
    Knaflic D; Mester U
    Fortschr Ophthalmol; 1990; 87(6):574-8. PubMed ID: 2086397
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Anatomical and functional results of endotamponade with heavy silicone oil - Densiron 68 - in complicated retinal detachment.
    Herbrig E; Sandner D; Engelmann K
    Ophthalmic Res; 2007; 39(4):198-206. PubMed ID: 17596752
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sutureless 23-gauge versus 20-gauge vitrectomy with silicone oil injection in rhegmatogenous retinal detachment.
    Narayanan R; Tibra N; Mathai A; Chhablani J; Kuppermann BD
    Retina; 2012 May; 32(5):1013-6. PubMed ID: 22366901
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Delayed presentation of emulsified subretinal silicone oil appearing as an inverse macular pseudohypopyon.
    Gosse E; Lochhead J
    JAMA Ophthalmol; 2013 May; 131(5):684-5. PubMed ID: 23494005
    [No Abstract]   [Full Text] [Related]  

  • 34. Effect of 360° episcleral band as adjunctive to pars plana vitrectomy and silicone oil tamponade in the management of myopic macular hole retinal detachment.
    Ghoraba HH; Mansour HO; Elgouhary SM
    Retina; 2014 Apr; 34(4):670-8. PubMed ID: 24013260
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Prevention of enucleation of two phthisic eyes by removal of extruding silicone scleral buckles.
    Glatt HJ; Miller JH
    Am J Ophthalmol; 1993 Nov; 116(5):645-6. PubMed ID: 8238230
    [No Abstract]   [Full Text] [Related]  

  • 36. Silicone oil emulsification at the fovea as a reversible cause of vision loss.
    Nicholson BP; Bakri SJ
    JAMA Ophthalmol; 2015 Apr; 133(4):484-6. PubMed ID: 25590568
    [No Abstract]   [Full Text] [Related]  

  • 37. Silicone sponge implant in combination with episcleral implant for retinal detachment surgery.
    Sakamoto DK; Zegarra H; Gutman FA; Zakov ZN
    Ophthalmic Surg; 1980 Oct; 11(10):712-8. PubMed ID: 7454210
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Retinal redetachment after silicone oil removal in proliferative vitreoretinopathy: a prognostic factor analysis.
    Lam RF; Cheung BT; Yuen CY; Wong D; Lam DS; Lai WW
    Am J Ophthalmol; 2008 Mar; 145(3):527-533. PubMed ID: 18191093
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Descemet membrane detachment after heavy silicone oil removal from the anterior chamber.
    Kymionis GD; Tsoulnaras KI; Xanthopoulou NA; Klados NE; Tsilimbaris MK
    Cornea; 2014 Mar; 33(3):317-8. PubMed ID: 24452220
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dystrophic calcification of silicone scleral buckling implant materials.
    Brockhurst RJ; Ward RC; Lou P; Ormerod D; Albert D
    Am J Ophthalmol; 1993 Apr; 115(4):524-9. PubMed ID: 8470727
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.