These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 11248759)

  • 1. Effect of altering vasoactivity on the measurement of finger blood pressure.
    Jagomägi K; Raamat R; Talts J
    Blood Press Monit; 2001 Feb; 6(1):33-40. PubMed ID: 11248759
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion.
    Raamat R; Jagomägi K; Talts J
    J Med Eng Technol; 2000; 24(3):95-101. PubMed ID: 11036575
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres).
    Dorlas JC; Nijboer JA; Butijn WT; van der Hoeven GM; Settels JJ; Wesseling KH
    Anesthesiology; 1985 Mar; 62(3):342-5. PubMed ID: 3977117
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method.
    Jagomägi K; Talts J; Raamat R; Länsimies E
    Clin Physiol; 1996 Sep; 16(5):551-60. PubMed ID: 8889318
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.
    Raamat R; Jagomägi K; Talts J; Länsimies E; Jurvelin J; Kolari P
    Med Biol Eng Comput; 2001 Sep; 39(5):584-9. PubMed ID: 11712656
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of temperature on finger artery pressure evaluated by volume clamp technique.
    Tanaka H; Thulesius O
    Clin Physiol; 1993 Sep; 13(5):535-45. PubMed ID: 8222538
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique.
    Birch AA
    Blood Press Monit; 2007 Oct; 12(5):315-9. PubMed ID: 17890970
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Portapres and differential oscillometric finger blood pressure changes during deep breathing test in the assessment of BRS index.
    Jagomägi K; Raamat R; Talts J; Länsimies E; Jurvelin J
    Clin Physiol Funct Imaging; 2003 Jan; 23(1):9-13. PubMed ID: 12558608
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change.
    Raamat R; Talts J; Jagomägi K; Kivastik J; Länsimies E; Jurvelin J
    J Med Eng Technol; 2006; 30(3):139-44. PubMed ID: 16772216
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.
    Epstein RH; Huffnagle S; Bartkowski RR
    J Clin Monit; 1991 Apr; 7(2):161-7. PubMed ID: 2072129
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of graded vasoconstriction upon the measurement of finger arterial pressure.
    Imholz BP; Parati G; Mancia G; Wesseling KH
    J Hypertens; 1992 Sep; 10(9):979-84. PubMed ID: 1328379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger.
    Wesseling KH; Settels JJ; van der Hoeven GM; Nijboer JA; Butijn MW; Dorlas JC
    Cardiovasc Res; 1985 Mar; 19(3):139-45. PubMed ID: 3986857
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Recording of short-term finger blood pressure changes induced by an arterial occlusive thigh cuff: comparison between the modified oscillometric and Finapres techniques.
    Raamat R; Jagomägi K; Talts J; Toska K; Walløe L
    Physiol Meas; 2001 May; 22(2):N13-20. PubMed ID: 11411252
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recording of dynamic arterial compliance changes during hand elevation.
    Jagomägi K; Raamat R; Talts J; Ragun U; Länsimies E; Jurvelin J
    Clin Physiol Funct Imaging; 2005 Nov; 25(6):350-6. PubMed ID: 16268987
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices.
    Lakhal K; Martin M; Faiz S; Ehrmann S; Blanloeil Y; Asehnoune K; Rozec B; Boulain T
    Anesth Analg; 2016 Nov; 123(5):1126-1135. PubMed ID: 27159068
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Agreement between finger plethysmography- and brachial oscillometry-derived blood pressure measurements.
    Allan PD; O'Donnell T; Tzeng YC
    Clin Physiol Funct Imaging; 2018 May; 38(3):439-446. PubMed ID: 28444896
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of invasive and non-invasive measurements of continuous arterial pressure using the Finapres.
    Stokes DN; Clutton-Brock T; Patil C; Thompson JM; Hutton P
    Br J Anaesth; 1991 Jul; 67(1):26-35. PubMed ID: 1859755
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An optical oscillometric method for neonatal and premature infant blood pressure monitoring.
    Roeder RA; Geddes LA
    Adv Neonatal Care; 2009 Apr; 9(2):77-81. PubMed ID: 19363328
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement of blood pressure in obese patients: reliability and value of finger measurement (Finapres)].
    Poncelet P; Durand P; Lechantre R; Mounier-Vehier C; Fouquoire B; Petetin N; Carré A
    Arch Mal Coeur Vaiss; 1992 Aug; 85(8):1165-8. PubMed ID: 1482253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility of noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years.
    Andriessen P; Schraa O; van Den Bosch-Ruis W; Jan Ten Harkel D; Settels JJ; Oetomo SB; Blanco CE
    Pediatr Res; 2008 Jun; 63(6):691-6. PubMed ID: 18520333
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.