These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 11255171)

  • 21. Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
    Torstrick FB; Evans NT; Stevens HY; Gall K; Guldberg RE
    Clin Orthop Relat Res; 2016 Nov; 474(11):2373-2383. PubMed ID: 27154533
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Parathyroid hormone treatment increases fixation of orthopedic implants with gap healing: a biomechanical and histomorphometric canine study of porous coated titanium alloy implants in cancellous bone.
    Daugaard H; Elmengaard B; Andreassen T; Bechtold J; Lamberg A; Soballe K
    Calcif Tissue Int; 2011 Apr; 88(4):294-303. PubMed ID: 21253714
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Trabecular bone adaptation to variations in porous-coated implant topology.
    Guldberg RE; Richards M; Caldwell NJ; Kuelske CL; Goldstein SA
    J Biomech; 1997 Feb; 30(2):147-53. PubMed ID: 9001935
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep.
    Palmquist A; Snis A; Emanuelsson L; Browne M; Thomsen P
    J Biomater Appl; 2013 May; 27(8):1003-16. PubMed ID: 22207608
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Studies on personalized porous titanium implant fabricated using three-dimensional printing forming technique].
    Xiong Y; Chen P; Sun J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Apr; 29(2):247-50. PubMed ID: 22616167
    [TBL] [Abstract][Full Text] [Related]  

  • 26.
    Fu J; Xiang Y; Ni M; Qu X; Zhou Y; Hao L; Zhang G; Chen J
    Biomed Res Int; 2020; 2020():4542302. PubMed ID: 33335923
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hydroxyapatite-coated porous titanium for use as an orthopedic biologic attachment system.
    Cook SD; Thomas KA; Kay JF; Jarcho M
    Clin Orthop Relat Res; 1988 May; (230):303-12. PubMed ID: 2835198
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Bone apposition to plasma-sprayed cobalt-chromium alloy.
    Luckey HA; Lamprecht EG; Walt MJ
    J Biomed Mater Res; 1992 May; 26(5):557-75. PubMed ID: 1512279
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Porous-coated uncemented components in experimental total hip arthroplasty in dogs. Effect of plasma-sprayed calcium phosphate coatings on bone ingrowth.
    Jasty M; Rubash HE; Paiement GD; Bragdon CR; Parr J; Harris WH
    Clin Orthop Relat Res; 1992 Jul; (280):300-9. PubMed ID: 1611761
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A high-modulus polymer for porous orthopedic implants: biomechanical compatibility of porous implants.
    Spector M; Michno MJ; Smarook WH; Kwiatkowski GT
    J Biomed Mater Res; 1978 Sep; 12(5):665-77. PubMed ID: 701302
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bone ingrowth to implant surfaces in an inflammatory arthritis model.
    An YH; Friedman RJ; Jiang M; LaBreck JC; Draughn RA; Butehorn HF; Bauer TW
    J Orthop Res; 1998 Sep; 16(5):576-84. PubMed ID: 9820281
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep.
    Bellemans J
    Acta Orthop Scand Suppl; 1999 Oct; 288():1-35. PubMed ID: 10949554
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fabrication of porous titanium implants by three-dimensional printing and sintering at different temperatures.
    Xiong Y; Qian C; Sun J
    Dent Mater J; 2012; 31(5):815-20. PubMed ID: 23037845
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone.
    Bobyn JD; Pilliar RM; Cameron HU; Weatherly GC
    Clin Orthop Relat Res; 1980; (150):263-70. PubMed ID: 7428231
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength.
    Hayashi K; Inadome T; Tsumura H; Nakashima Y; Sugioka Y
    Biomaterials; 1994 Nov; 15(14):1187-91. PubMed ID: 7534485
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Titanium metals form direct bonding to bone after alkali and heat treatments.
    Nishiguchi S; Kato H; Fujita H; Oka M; Kim HM; Kokubo T; Nakamura T
    Biomaterials; 2001 Sep; 22(18):2525-33. PubMed ID: 11516085
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Hjortdal VE; Juhl GI; Pedersen CM; Hvid I; Bünger C
    J Arthroplasty; 1991 Dec; 6(4):307-16. PubMed ID: 1663154
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Bone response to a novel highly porous surface in a canine implantable chamber.
    Frenkel SR; Jaffe WL; Dimaano F; Iesaka K; Hua T
    J Biomed Mater Res B Appl Biomater; 2004 Nov; 71(2):387-91. PubMed ID: 15389510
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis.
    Walenciak MT; Zimmerman MC; Harten RD; Ricci JL; Stamer DT
    J Biomed Mater Res; 1996 Aug; 31(4):465-74. PubMed ID: 8836842
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.