128 related articles for article (PubMed ID: 11262166)
1. Detection of multivalent interactions through two-tiered energy transfer.
Song X; Shi J; Nolan J; Swanson B
Anal Biochem; 2001 Apr; 291(1):133-41. PubMed ID: 11262166
[TBL] [Abstract][Full Text] [Related]
2. Flow cytometry-based biosensor for detection of multivalent proteins.
Song X; Shi J; Swanson B
Anal Biochem; 2000 Aug; 284(1):35-41. PubMed ID: 10933853
[TBL] [Abstract][Full Text] [Related]
3. Direct, ultrasensitive, and selective optical detection of protein toxins using multivalent interactions.
Song X; Swanson BI
Anal Chem; 1999 Jun; 71(11):2097-107. PubMed ID: 10366891
[TBL] [Abstract][Full Text] [Related]
4. Manipulating FRET with polymeric vesicles: development of a "mix-and-detect" type fluorescence sensor for bacterial toxin.
Ma G; Cheng Q
Langmuir; 2006 Aug; 22(16):6743-5. PubMed ID: 16863214
[TBL] [Abstract][Full Text] [Related]
5. Fluorescent BODIPY-labelled GM1 gangliosides designed for exploring lipid membrane properties and specific membrane-target interactions.
Mikhalyov I; Gretskaya N; Johansson LB
Chem Phys Lipids; 2009 May; 159(1):38-44. PubMed ID: 19428361
[TBL] [Abstract][Full Text] [Related]
6. A flow cytometric method to detect protein-protein interaction in living cells by directly visualizing donor fluorophore quenching during CFP-->YFP fluorescence resonance energy transfer (FRET).
He L; Olson DP; Wu X; Karpova TS; McNally JG; Lipsky PE
Cytometry A; 2003 Oct; 55(2):71-85. PubMed ID: 14505312
[TBL] [Abstract][Full Text] [Related]
7. Synthesis of novel NBD-GM1 and NBD-GM2 for the transfer activity of GM2-activator protein by a FRET-based assay system.
Schwarzmann G; Wendeler M; Sandhoff K
Glycobiology; 2005 Dec; 15(12):1302-11. PubMed ID: 16079415
[TBL] [Abstract][Full Text] [Related]
8. Peptides, antibodies, and FRET on beads in flow cytometry: A model system using fluoresceinated and biotinylated beta-endorphin.
Buranda T; Lopez GP; Keij J; Harris R; Sklar LA
Cytometry; 1999 Sep; 37(1):21-31. PubMed ID: 10451503
[TBL] [Abstract][Full Text] [Related]
9. Flow cytometric measurement of fluorescence (Förster) resonance energy transfer from cyan fluorescent protein to yellow fluorescent protein using single-laser excitation at 458 nm.
He L; Bradrick TD; Karpova TS; Wu X; Fox MH; Fischer R; McNally JG; Knutson JR; Grammer AC; Lipsky PE
Cytometry A; 2003 May; 53(1):39-54. PubMed ID: 12701131
[TBL] [Abstract][Full Text] [Related]
10. Nanodiscs for immobilization of lipid bilayers and membrane receptors: kinetic analysis of cholera toxin binding to a glycolipid receptor.
Borch J; Torta F; Sligar SG; Roepstorff P
Anal Chem; 2008 Aug; 80(16):6245-52. PubMed ID: 18616345
[TBL] [Abstract][Full Text] [Related]
11. Conformational changes in cholera toxin B subunit-ganglioside GM1 complexes are elicited by environmental pH and evoke changes in membrane structure.
McCann JA; Mertz JA; Czworkowski J; Picking WD
Biochemistry; 1997 Jul; 36(30):9169-78. PubMed ID: 9230049
[TBL] [Abstract][Full Text] [Related]
12. Measurement of the binding of cholera toxin to GM1 gangliosides on solid supported lipid bilayer vesicles and inhibition by europium (III) chloride.
Williams TL; Jenkins AT
J Am Chem Soc; 2008 May; 130(20):6438-43. PubMed ID: 18412339
[TBL] [Abstract][Full Text] [Related]
13. A novel design method of ratiometric fluorescent probes based on fluorescence resonance energy transfer switching by spectral overlap integral.
Takakusa H; Kikuchi K; Urano Y; Kojima H; Nagano T
Chemistry; 2003 Apr; 9(7):1479-85. PubMed ID: 12658644
[TBL] [Abstract][Full Text] [Related]
14. Dissecting the cholera toxin-ganglioside GM1 interaction by isothermal titration calorimetry.
Turnbull WB; Precious BL; Homans SW
J Am Chem Soc; 2004 Feb; 126(4):1047-54. PubMed ID: 14746472
[TBL] [Abstract][Full Text] [Related]
15. Position-specific incorporation of fluorescent non-natural amino acids into maltose-binding protein for detection of ligand binding by FRET and fluorescence quenching.
Iijima I; Hohsaka T
Chembiochem; 2009 Apr; 10(6):999-1006. PubMed ID: 19301314
[TBL] [Abstract][Full Text] [Related]
16. Stable and fluid ethylphosphocholine membranes in a poly(dimethylsiloxane) microsensor for toxin detection in flooded waters.
Phillips KS; Dong Y; Carter D; Cheng Q
Anal Chem; 2005 May; 77(9):2960-5. PubMed ID: 15859616
[TBL] [Abstract][Full Text] [Related]
17. Direct fluorescence-based detection methods for multivalent interactions.
Song X; Shi J; Swanson BI
Methods Enzymol; 2003; 362():523-42. PubMed ID: 12968386
[No Abstract] [Full Text] [Related]
18. Detection of receptor clustering by flow cytometric fluorescence anisotropy measurements.
Bene L; Fulwyler MJ; Damjanovich S
Cytometry; 2000 Aug; 40(4):292-306. PubMed ID: 10918280
[TBL] [Abstract][Full Text] [Related]
19. An ultrasensitive chemiluminescence biosensor for cholera toxin based on ganglioside-functionalized supported lipid membrane and liposome.
Chen H; Zheng Y; Jiang JH; Wu HL; Shen GL; Yu RQ
Biosens Bioelectron; 2008 Dec; 24(4):684-9. PubMed ID: 18672355
[TBL] [Abstract][Full Text] [Related]
20. Lipid mobility and molecular binding in fluid lipid membranes.
Yamazaki V; Sirenko O; Schafer RJ; Groves JT
J Am Chem Soc; 2005 Mar; 127(9):2826-7. PubMed ID: 15740098
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]