These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
222 related articles for article (PubMed ID: 11263620)
1. Quantification of renal blood flow with contrast-enhanced ultrasound. Wei K; Le E; Bin JP; Coggins M; Thorpe J; Kaul S J Am Coll Cardiol; 2001 Mar; 37(4):1135-40. PubMed ID: 11263620 [TBL] [Abstract][Full Text] [Related]
2. [Quantitative evaluation of canine renal blood flow with contrast-enhanced ultrasound]. Xiao WX; Bin JP; Xie JG; Liu J; Cha DG; Xu DL Di Yi Jun Yi Da Xue Xue Bao; 2005 Apr; 25(4):411-2, 415. PubMed ID: 15837640 [TBL] [Abstract][Full Text] [Related]
3. Renal blood flow measurement with contrast-enhanced harmonic ultrasonography: evaluation of dopamine-induced changes in renal cortical perfusion in humans. Kishimoto N; Mori Y; Nishiue T; Shibasaki Y; Iba O; Nose A; Uchiyama-Tanaka Y; Masaki H; Matsubara H; Iwasaka T Clin Nephrol; 2003 Jun; 59(6):423-8. PubMed ID: 12834173 [TBL] [Abstract][Full Text] [Related]
4. Quantitative evaluation of microvascular blood flow by contrast-enhanced ultrasound (CEUS). Greis C Clin Hemorheol Microcirc; 2011; 49(1-4):137-49. PubMed ID: 22214685 [TBL] [Abstract][Full Text] [Related]
5. Contrast-enhanced ultrasound identifies reduced overall and regional renal perfusion during global hypoxia in piglets. Brabrand K; de Lange C; Emblem KE; Reinholt FP; Saugstad OD; Stokke ES; Munkeby BH Invest Radiol; 2014 Aug; 49(8):540-6. PubMed ID: 24637585 [TBL] [Abstract][Full Text] [Related]
6. Ultrasonic microbubble contrast agents and the transplant kidney. Kay DH; Mazonakis M; Geddes C; Baxter G Clin Radiol; 2009 Nov; 64(11):1081-7. PubMed ID: 19822241 [TBL] [Abstract][Full Text] [Related]
7. An investigation of the detection capability of pulsed wave duplex Doppler of low grade stenosis using ultrasound contrast agent microbubbles - An in-vitro study. Browne JE; King D; Fagan AJ; Chari D; Moran CM Ultrasonics; 2019 Jul; 96():48-54. PubMed ID: 31004864 [TBL] [Abstract][Full Text] [Related]
8. Renal blood flow quantification in pigs using contrast-enhanced ultrasound: an ex vivo study. Hoeffel C; Mulé S; Huwart L; Frouin F; Jais JP; Helenon O; Correas JM Ultraschall Med; 2010 Aug; 31(4):363-9. PubMed ID: 20408121 [TBL] [Abstract][Full Text] [Related]
9. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Wei K; Jayaweera AR; Firoozan S; Linka A; Skyba DM; Kaul S Circulation; 1998 Feb; 97(5):473-83. PubMed ID: 9490243 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of regional hepatic perfusion (RHP) by contrast-enhanced ultrasound in patients with cirrhosis. Berzigotti A; Nicolau C; Bellot P; Abraldes JG; Gilabert R; García-Pagan JC; Bosch J J Hepatol; 2011 Aug; 55(2):307-14. PubMed ID: 21167236 [TBL] [Abstract][Full Text] [Related]
13. A new technique for assessing renal transplant perfusion preoperatively using contrast-enhanced ultrasound (CEUS) and three-dimensional ultrasound (3DUS)--a porcine model pilot study. Stenberg B; Talbot D; Khurram M; Kanwar A; Ray C; Mownah O; White K; Elliott ST Ultraschall Med; 2011 Dec; 32 Suppl 2():E8-13. PubMed ID: 22179806 [TBL] [Abstract][Full Text] [Related]
14. Rest-Stress Limb Perfusion Imaging in Humans with Contrast Ultrasound Using Intermediate-Power Imaging and Microbubbles Resistant to Inertial Cavitation. Davidson BP; Hodovan J; Belcik JT; Moccetti F; Xie A; Ammi AY; Lindner JR J Am Soc Echocardiogr; 2017 May; 30(5):503-510.e1. PubMed ID: 28238588 [TBL] [Abstract][Full Text] [Related]
15. Renal perfusion parameters measured by contrast-enhanced ultrasound in healthy dogs demonstrate a wide range of variability in the long-term. Liu DJX; Hesta M; Stock E; Bogaerts E; Broeckx BJG; Saunders JH; Vanderperren K Vet Radiol Ultrasound; 2019 Mar; 60(2):201-209. PubMed ID: 30276919 [TBL] [Abstract][Full Text] [Related]
16. Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. Linka AZ; Sklenar J; Wei K; Jayaweera AR; Skyba DM; Kaul S Circulation; 1998 Nov; 98(18):1912-20. PubMed ID: 9799213 [TBL] [Abstract][Full Text] [Related]
17. The lognormal perfusion model for disruption replenishment measurements of blood flow: in vivo validation. Hudson JM; Leung K; Burns PN Ultrasound Med Biol; 2011 Oct; 37(10):1571-8. PubMed ID: 21821351 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of renal cortical perfusion by noninvasive power Doppler ultrasound during vascular occlusion and reperfusion. Kuwa T; Cancio LC; Sondeen JL; Matylevich N; Jordan BS; McManus AT; Goodwin CW J Trauma; 2004 Mar; 56(3):618-24. PubMed ID: 15128134 [TBL] [Abstract][Full Text] [Related]
19. [Quantification of renal medullary perfusion with contrast-enhanced ultrasound: an experimental study]. Xie WJ; Xing XW; Bin JP; Xie JG; Zha DG; Liu YL Di Yi Jun Yi Da Xue Xue Bao; 2005 Jul; 25(7):778-81. PubMed ID: 16027065 [TBL] [Abstract][Full Text] [Related]