These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
157 related articles for article (PubMed ID: 11274534)
1. Automated polyp detection at CT colonography: feasibility assessment in a human population. Summers RM; Johnson CD; Pusanik LM; Malley JD; Youssef AM; Reed JE Radiology; 2001 Apr; 219(1):51-9. PubMed ID: 11274534 [TBL] [Abstract][Full Text] [Related]
2. Colonic polyps: complementary role of computer-aided detection in CT colonography. Summers RM; Jerebko AK; Franaszek M; Malley JD; Johnson CD Radiology; 2002 Nov; 225(2):391-9. PubMed ID: 12409571 [TBL] [Abstract][Full Text] [Related]
3. [CT-colonography with the 16-slice CT for the diagnostic evaluation of colorectal neoplasms and inflammatory colon diseases]. Röttgen R; Schröder RJ; Lorenz M; Herbel A; Fischbach F; Herzog H; Lopez-Häninnen E; Gutberlet M; Hoffmann K; Helmig K; Felix R Rofo; 2003 Oct; 175(10):1384-91. PubMed ID: 14556108 [TBL] [Abstract][Full Text] [Related]
4. Comparison of supine and prone scanning separately and in combination at CT colonography. Yee J; Kumar NN; Hung RK; Akerkar GA; Kumar PR; Wall SD Radiology; 2003 Mar; 226(3):653-61. PubMed ID: 12601201 [TBL] [Abstract][Full Text] [Related]
5. CT colonography: value of scanning in both the supine and prone positions. Chen SC; Lu DS; Hecht JR; Kadell BM AJR Am J Roentgenol; 1999 Mar; 172(3):595-9. PubMed ID: 10063842 [TBL] [Abstract][Full Text] [Related]
6. CT colonography with computer-aided polyp detection: volume and attenuation thresholds to reduce false-positive findings owing to the ileocecal valve. O'Connor SD; Summers RM; Yao J; Pickhardt PJ; Choi JR Radiology; 2006 Nov; 241(2):426-32. PubMed ID: 17005773 [TBL] [Abstract][Full Text] [Related]
7. Virtual colon dissection with CT colonography compared with axial interpretation and conventional colonoscopy: preliminary results. Hoppe H; Quattropani C; Spreng A; Mattich J; Netzer P; Dinkel HP AJR Am J Roentgenol; 2004 May; 182(5):1151-8. PubMed ID: 15100110 [TBL] [Abstract][Full Text] [Related]
9. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study. Li P; Napel S; Acar B; Paik DS; Jeffrey RB; Beaulieu CF Med Phys; 2004 Oct; 31(10):2912-23. PubMed ID: 15543800 [TBL] [Abstract][Full Text] [Related]
10. Computer-aided detection of colonic polyps at CT colonography using a Hessian matrix-based algorithm: preliminary study. Kim SH; Lee JM; Lee JG; Kim JH; Lefere PA; Han JK; Choi BI AJR Am J Roentgenol; 2007 Jul; 189(1):41-51. PubMed ID: 17579150 [TBL] [Abstract][Full Text] [Related]
11. Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps. Yoshida H; Näppi J IEEE Trans Med Imaging; 2001 Dec; 20(12):1261-74. PubMed ID: 11811826 [TBL] [Abstract][Full Text] [Related]
12. Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies. Iannaccone R; Catalano C; Mangiapane F; Murakami T; Lamazza A; Fiori E; Schillaci A; Marin D; Nofroni I; Hori M; Passariello R Radiology; 2005 Dec; 237(3):927-37. PubMed ID: 16304113 [TBL] [Abstract][Full Text] [Related]
13. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings. Baker ME; Bogoni L; Obuchowski NA; Dass C; Kendzierski RM; Remer EM; Einstein DM; Cathier P; Jerebko A; Lakare S; Blum A; Caroline DF; Macari M Radiology; 2007 Oct; 245(1):140-9. PubMed ID: 17885187 [TBL] [Abstract][Full Text] [Related]
14. False-negative results at multi-detector row CT colonography: multivariate analysis of causes for missed lesions. Park SH; Ha HK; Kim MJ; Kim KW; Kim AY; Yang DH; Lee MG; Kim PN; Shin YM; Yang SK; Myung SJ; Min YI Radiology; 2005 May; 235(2):495-502. PubMed ID: 15770042 [TBL] [Abstract][Full Text] [Related]
15. Computer-aided diagnosis scheme for detection of polyps at CT colonography. Yoshida H; Näppi J; MacEneaney P; Rubin DT; Dachman AH Radiographics; 2002; 22(4):963-79. PubMed ID: 12110726 [TBL] [Abstract][Full Text] [Related]
17. CT colonography with computer-aided detection: automated recognition of ileocecal valve to reduce number of false-positive detections. Summers RM; Yao J; Johnson CD Radiology; 2004 Oct; 233(1):266-72. PubMed ID: 15454623 [TBL] [Abstract][Full Text] [Related]
18. Nonlaxative PET/CT colonography: feasibility, acceptability, and pilot performance in patients at higher risk of colonic neoplasia. Taylor SA; Bomanji JB; Manpanzure L; Robinson C; Groves AM; Dickson J; Papathanasiou ND; Greenhalgh R; Ell PJ; Halligan S J Nucl Med; 2010 Jun; 51(6):854-61. PubMed ID: 20484420 [TBL] [Abstract][Full Text] [Related]
19. Colorectal polyps and cancers in asymptomatic average-risk patients: evaluation with CT colonography. Macari M; Bini EJ; Jacobs SL; Naik S; Lui YW; Milano A; Rajapaksa R; Megibow AJ; Babb J Radiology; 2004 Mar; 230(3):629-36. PubMed ID: 14739311 [TBL] [Abstract][Full Text] [Related]