These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 11292110)
1. Respiratory inductance plethysmography in healthy infants: a comparison of three calibration methods. Poole KA; Thompson JR; Hallinan HM; Beardsmore CS Eur Respir J; 2000 Dec; 16(6):1084-90. PubMed ID: 11292110 [TBL] [Abstract][Full Text] [Related]
2. Tidal volume measurements in newborns using respiratory inductive plethysmography. Adams JA; Zabaleta IA; Stroh D; Johnson P; Sackner MA Am Rev Respir Dis; 1993 Sep; 148(3):585-88. PubMed ID: 8368627 [TBL] [Abstract][Full Text] [Related]
3. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs. Warren RH; Fewell JE; Alderson SH Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411 [TBL] [Abstract][Full Text] [Related]
4. Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography, The CHIME Study Group. Collaborative Home Infant Monitoring Evaluation. Brooks LJ; DiFiore JM; Martin RJ Pediatr Pulmonol; 1997 Jun; 23(6):429-33. PubMed ID: 9220525 [TBL] [Abstract][Full Text] [Related]
6. Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants. Brown K; Aun C; Jackson E; Mackersie A; Hatch D; Stocks J Eur Respir J; 1998 Oct; 12(4):935-43. PubMed ID: 9817172 [TBL] [Abstract][Full Text] [Related]
7. Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions. Emeriaud G; Eberhard A; Benchetrit G; Debillon T; Baconnier P Pediatr Pulmonol; 2008 Nov; 43(11):1135-1141. PubMed ID: 18846561 [TBL] [Abstract][Full Text] [Related]
8. Comparison of calibration methods for respiratory inductive plethysmography in infants. Revow MD; England SJ; Stogryn HA; Wilkes DL J Appl Physiol (1985); 1987 Nov; 63(5):1853-61. PubMed ID: 3693219 [TBL] [Abstract][Full Text] [Related]
9. A critical assessment of uncalibrated respiratory inductance plethysmography (Respitrace) for the measurement of tidal breathing parameters in newborns and infants. Jackson E; Stocks J; Pilgrim L; Dundas I; Dezateux C Pediatr Pulmonol; 1995 Aug; 20(2):119-24. PubMed ID: 8570302 [TBL] [Abstract][Full Text] [Related]
10. Calibration of respiratory inductive plethysmography in lambs receiving intermittent mandatory mechanical ventilation. Warren RH; Alderson SH Crit Care Med; 1988 Feb; 16(2):161-4. PubMed ID: 3277774 [TBL] [Abstract][Full Text] [Related]
11. Pulmonary mechanics measurements by respiratory inductive plethysmography and esophageal manometry: Methodology for infants on non-invasive respiratory support. Sivieri EM; Wolfson MR; Abbasi S J Neonatal Perinatal Med; 2019; 12(2):149-159. PubMed ID: 30714976 [TBL] [Abstract][Full Text] [Related]
12. Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs. Warren RH; Fewell JE; Alderson SH J Dev Physiol; 1989 Dec; 12(6):347-52. PubMed ID: 2640229 [TBL] [Abstract][Full Text] [Related]
13. Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants. Gagliardi L; Rusconi F; Aston H; Silverman M Pediatr Pulmonol; 1996 Feb; 21(2):132-7. PubMed ID: 8882215 [TBL] [Abstract][Full Text] [Related]
14. Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model. Khemani RG; Flink R; Hotz J; Ross PA; Ghuman A; Newth CJ Pediatr Res; 2015 Jan; 77(1-1):75-83. PubMed ID: 25279987 [TBL] [Abstract][Full Text] [Related]
15. Calibration of respiratory inductive plethysmograph during natural breathing. Sackner MA; Watson H; Belsito AS; Feinerman D; Suarez M; Gonzalez G; Bizousky F; Krieger B J Appl Physiol (1985); 1989 Jan; 66(1):410-20. PubMed ID: 2917945 [TBL] [Abstract][Full Text] [Related]
16. Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography. De Groote A; Paiva M; Verbandt Y J Appl Physiol (1985); 2001 Mar; 90(3):1025-30. PubMed ID: 11181615 [TBL] [Abstract][Full Text] [Related]
17. Respiratory inductive plethysmography: a comparative study between isovolume maneuver calibration and qualitative diagnostic calibration in healthy volunteers assessed in different positions. Barbosa RC; Carvalho CR; Moriya HT J Bras Pneumol; 2012; 38(2):194-201. PubMed ID: 22576427 [TBL] [Abstract][Full Text] [Related]
18. Validation of Respiratory Inductance Plethysmography for Measuring Tidal Volume in Swine. Su Z; Oto J; Wang J; Kimball WR; Chenelle CT; Kacmarek RM; King DR; Jiang Y; Duggan MJ Comp Med; 2015 Jun; 65(3):225-31. PubMed ID: 26141447 [TBL] [Abstract][Full Text] [Related]
19. Spectral characteristics of airway opening and chest wall tidal flows in spontaneously breathing preterm infants. Habib RH; Pyon KH; Courtney SE; Aghai ZH J Appl Physiol (1985); 2003 May; 94(5):1933-40. PubMed ID: 12524380 [TBL] [Abstract][Full Text] [Related]
20. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture. Stradling JR; Chadwick GA; Quirk C; Phillips T Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]