These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
93 related articles for article (PubMed ID: 1130240)
1. Electronic tonometry in the newborn. Dominguez A; Alvarez MG; Banos MS Adv Ophthalmol; 1975; 29():88-125. PubMed ID: 1130240 [TBL] [Abstract][Full Text] [Related]
2. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
3. [Measurement of ocular tension in the newborn with the Mackay-Marg electronic tonometer]. Trux E; Follmann P Bull Mem Soc Fr Ophtalmol; 1969; 82():48-53. PubMed ID: 5402423 [No Abstract] [Full Text] [Related]
4. Non-contact and Mackay-Marg tonometry: comparison in patients ages 7 to 85 years. Augsburger A; Terry JE Am J Optom Physiol Opt; 1977 Jan; 54(1):31-4. PubMed ID: 871146 [TBL] [Abstract][Full Text] [Related]
5. [Reliable measurements of intraocular pressure in infants using the Mackay-Marg electronic tonometer without general and local anesthesia]. Mucsi G; Littmann J; Follmann P Klin Monbl Augenheilkd; 1971 Mar; 158(3):417-21. PubMed ID: 5573463 [No Abstract] [Full Text] [Related]
6. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry. Popovich KS; Shields MB J Glaucoma; 1997 Feb; 6(1):44-6. PubMed ID: 9075080 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of three applanation tonometers in dogs. Priehs DR; Gum GG; Whitley RD; Moore LE Am J Vet Res; 1990 Oct; 51(10):1547-50. PubMed ID: 2240775 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of electronic tonometers in the rabbit eye. Gelatt KN; Gum GG Am J Vet Res; 1981 Oct; 42(10):1778-81. PubMed ID: 7325441 [TBL] [Abstract][Full Text] [Related]
9. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes]. Deuter CM; Schlote T; Hahn GA; Bende T; Derse M Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of two applanation tonometers in cats. Miller PE; Pickett JP; Majors LJ; Kurzman ID Am J Vet Res; 1991 Nov; 52(11):1917-21. PubMed ID: 1785739 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of applanation tonometers for the dog eye. Gelatt KN; Peiffer RL; Gum GG; Gwin RM; Erickson JL Invest Ophthalmol Vis Sci; 1977 Oct; 16(10):963-8. PubMed ID: 908649 [TBL] [Abstract][Full Text] [Related]