BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 11302823)

  • 1. Prolonged antimicrobial activity of a catheter containing chlorhexidine-silver sulfadiazine extends protection against catheter infections in vivo.
    Bassetti S; Hu J; D'Agostino RB; Sherertz RJ
    Antimicrob Agents Chemother; 2001 May; 45(5):1535-8. PubMed ID: 11302823
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Silver iontophoretic catheter: a prototype of a long-term antiinfective vascular access device.
    Raad I; Hachem R; Zermeno A; Stephens LC; Bodey GP
    J Infect Dis; 1996 Feb; 173(2):495-8. PubMed ID: 8568321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of an antimicrobial-impregnated continuous ambulatory peritoneal dialysis catheter for infection control in rats.
    Kim CY; Kumar A; Sampath L; Sokol K; Modak S
    Am J Kidney Dis; 2002 Jan; 39(1):165-73. PubMed ID: 11774116
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo efficacy of antimicrobial-coated fabric from prosthetic heart valve sewing rings.
    Darouiche RO; Meade R; Mansouri M; Raad II
    J Heart Valve Dis; 1998 Nov; 7(6):639-46. PubMed ID: 9870198
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of a triple-lumen central venous heparin-coated catheter versus a catheter coated with chlorhexidine and silver sulfadiazine in critically ill patients.
    Carrasco MN; Bueno A; de las Cuevas C; Jimenez S; Salinas I; Sartorius A; Recio T; Generelo M; Ruiz-Ocaña F
    Intensive Care Med; 2004 Apr; 30(4):633-8. PubMed ID: 14722639
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Susceptibility of coagulase-negative staphylococcal nosocomial bloodstream isolates to the chlorhexidine/silver sulfadiazine-impregnated central venous catheter.
    Rosato AE; Tallent SM; Edmond MB; Bearman GM
    Am J Infect Control; 2004 Dec; 32(8):486-8. PubMed ID: 15573055
    [No Abstract]   [Full Text] [Related]  

  • 7. The broad-spectrum activity and efficacy of catheters coated with minocycline and rifampin.
    Raad I; Darouiche R; Hachem R; Mansouri M; Bodey GP
    J Infect Dis; 1996 Feb; 173(2):418-24. PubMed ID: 8568304
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. A randomized, controlled trial.
    Maki DG; Stolz SM; Wheeler S; Mermel LA
    Ann Intern Med; 1997 Aug; 127(4):257-66. PubMed ID: 9265424
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremia.
    Heard SO; Wagle M; Vijayakumar E; McLean S; Brueggemann A; Napolitano LM; Edwards LP; O'Connell FM; Puyana JC; Doern GV
    Arch Intern Med; 1998 Jan; 158(1):81-7. PubMed ID: 9437382
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of chlorhexidine-silver sulfadiazine-impregnated central venous catheters on in vitro quantitation of catheter-associated bacteria.
    Schmitt SK; Knapp C; Hall GS; Longworth DL; McMahon JT; Washington JA
    J Clin Microbiol; 1996 Mar; 34(3):508-11. PubMed ID: 8904403
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of ultrasonic-induced chlorhexidine liberation: correlation of the activity of chlorhexidine-silver-sulfadiazine-impregnated catheters to agar roll technique and broth culture.
    Schierholz JM; Bach A; Fleck C; Beuth J; König D; Pulverer G
    J Hosp Infect; 2000 Feb; 44(2):141-5. PubMed ID: 10662565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro zones of inhibition of coated vascular catheters predict efficacy in preventing catheter infection with Staphylococcus aureus in vivo.
    Bassetti S; Hu J; D'Agostino RB; Sherertz RJ
    Eur J Clin Microbiol Infect Dis; 2000 Aug; 19(8):612-7. PubMed ID: 11014624
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anti-infective external coating of central venous catheters: a randomized, noninferiority trial comparing 5-fluorouracil with chlorhexidine/silver sulfadiazine in preventing catheter colonization.
    Walz JM; Avelar RL; Longtine KJ; Carter KL; Mermel LA; Heard SO;
    Crit Care Med; 2010 Nov; 38(11):2095-102. PubMed ID: 20711070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro and in vivo efficacy of catheters impregnated with antiseptics or antibiotics: evaluation of the risk of bacterial resistance to the antimicrobials in the catheters.
    Sampath LA; Tambe SM; Modak SM
    Infect Control Hosp Epidemiol; 2001 Oct; 22(10):640-6. PubMed ID: 11776351
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On-demand antimicrobial release from a temperature-sensitive polymer - comparison with ad libitum release from central venous catheters.
    Sjollema J; Dijkstra RJ; Abeln C; van der Mei HC; van Asseldonk D; Busscher HJ
    J Control Release; 2014 Aug; 188():61-6. PubMed ID: 24950430
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the antimicrobial efficacy of urinary catheters impregnated with antiseptics in an in vitro urinary tract model.
    Gaonkar TA; Sampath LA; Modak SM
    Infect Control Hosp Epidemiol; 2003 Jul; 24(7):506-13. PubMed ID: 12887239
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of microbial adherence to antiseptic and antibiotic central venous catheters using a novel agar subcutaneous infection model.
    Gaonkar TA; Modak SM
    J Antimicrob Chemother; 2003 Sep; 52(3):389-96. PubMed ID: 12917250
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of a second-generation venous catheter impregnated with chlorhexidine and silver sulfadiazine on central catheter-related infections: a randomized, controlled trial.
    Rupp ME; Lisco SJ; Lipsett PA; Perl TM; Keating K; Civetta JM; Mermel LA; Lee D; Dellinger EP; Donahoe M; Giles D; Pfaller MA; Maki DG; Sherertz R
    Ann Intern Med; 2005 Oct; 143(8):570-80. PubMed ID: 16230723
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficacy of antibiotic-coated catheters in preventing subcutaneous Staphylococcus aureus infection in rabbits.
    Sherertz RJ; Carruth WA; Hampton AA; Byron MP; Solomon DD
    J Infect Dis; 1993 Jan; 167(1):98-106. PubMed ID: 7734001
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patients.
    Sheng WH; Ko WJ; Wang JT; Chang SC; Hsueh PR; Luh KT
    Diagn Microbiol Infect Dis; 2000 Sep; 38(1):1-5. PubMed ID: 11025176
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.