These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

497 related articles for article (PubMed ID: 11307410)

  • 21. Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety).
    Sánchez-Garcés MA; Jorba M; Ciurana J; Vinas M; Vinuesa MT
    Med Oral Patol Oral Cir Bucal; 2019 Sep; 24(5):e583-e587. PubMed ID: 31433387
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Morphologic studies on the biologic seal of titanium dental implants. Report II. In vivo study on the defending mechanism of epithelial adhesions/attachment against invasive factors.
    Kawahara H; Kawahara D; Mimura Y; Takashima Y; Ong JL
    Int J Oral Maxillofac Implants; 1998; 13(4):465-73. PubMed ID: 9714952
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of residual contamination on healing abutments after cleaning with a protein-denaturing agent and detergent.
    Kyaw TT; Nakata H; Takayuki M; Kuroda S; Kasugai S
    Quintessence Int; 2020; 51(6):474-485. PubMed ID: 32424376
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of pre-soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic files.
    Aasim SA; Mellor AC; Qualtrough AJ
    Int Endod J; 2006 Feb; 39(2):143-9. PubMed ID: 16454795
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Contemporary Sterilization Protocols of Healing Abutments for Reusability: A Systematic Review.
    Eswaramurthy P; Aras M; DSouza KM; Nagarsekar A; Gaunkar RB
    JDR Clin Trans Res; 2022 Oct; 7(4):352-359. PubMed ID: 34617805
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of surface processing on the attachment, orientation, and proliferation of human gingival fibroblasts on titanium.
    Könönen M; Hormia M; Kivilahti J; Hautaniemi J; Thesleff I
    J Biomed Mater Res; 1992 Oct; 26(10):1325-41. PubMed ID: 1429750
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Laser therapy accelerates initial attachment and subsequent behaviour of human oral fibroblasts cultured on titanium implant material. A scanning electron microscope and histomorphometric analysis.
    Khadra M; Kasem N; Lyngstadaas SP; Haanaes HR; Mustafa K
    Clin Oral Implants Res; 2005 Apr; 16(2):168-75. PubMed ID: 15777326
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Different experimental protocols for decontamination affect the cleaning of medical devices. A preliminary electron microscopy analysis.
    Tessarolo F; Caola I; Fedel M; Stacchiotti A; Caciagli P; Guarrera GM; Motta A; Nollo G
    J Hosp Infect; 2007 Apr; 65(4):326-33. PubMed ID: 17241696
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The implant-abutment interface of alumina and zirconia abutments.
    Yüzügüllü B; Avci M
    Clin Implant Dent Relat Res; 2008 May; 10(2):113-21. PubMed ID: 18218054
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of biological debris on endodontic instruments after cleaning and sterilization procedures.
    Popovic J; Gasic J; Zivkovic S; Petrovic A; Radicevic G
    Int Endod J; 2010 Apr; 43(4):336-41. PubMed ID: 20487454
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bone cell attachment to dental implants of different surface characteristics.
    Lumbikanonda N; Sammons R
    Int J Oral Maxillofac Implants; 2001; 16(5):627-36. PubMed ID: 11669244
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of osteoblast spreading on microstructured dental implant surfaces and cell behaviour in an explant model of osseointegration. A scanning electron microscopic study.
    Sammons RL; Lumbikanonda N; Gross M; Cantzler P
    Clin Oral Implants Res; 2005 Dec; 16(6):657-66. PubMed ID: 16307572
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Attachment of human primary osteoblast cells to modified polyethylene surfaces.
    Poulsson AH; Mitchell SA; Davidson MR; Johnstone AJ; Emmison N; Bradley RH
    Langmuir; 2009 Apr; 25(6):3718-27. PubMed ID: 19275183
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Surface properties correlated with the human gingival fibroblasts attachment on various materials for implant abutments: a multiple regression analysis.
    Kim YS; Shin SY; Moon SK; Yang SM
    Acta Odontol Scand; 2015 Jan; 73(1):38-47. PubMed ID: 25183254
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hard tissue response to argon plasma cleaning/sterilisation of customised titanium abutments versus 5-second steam cleaning: results of a 2-year post-loading follow-up from an explanatory randomised controlled trial in periodontally healthy patients.
    Canullo L; Penarrocha D; Micarelli C; Massidda O; Bazzoli M
    Eur J Oral Implantol; 2013; 6(3):251-60. PubMed ID: 24179979
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Soft tissue cell adhesion to titanium abutments after different cleaning procedures: preliminary results of a randomized clinical trial.
    Canullo L; Penarrocha-Oltra D; Marchionni S; Bagán L; Peñarrocha-Diago MA; Micarelli C
    Med Oral Patol Oral Cir Bucal; 2014 Mar; 19(2):e177-83. PubMed ID: 24121917
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures.
    Van Eldik DA; Zilm PS; Rogers AH; Marin PD
    Aust Dent J; 2004 Sep; 49(3):128-35. PubMed ID: 15497356
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dental implant materials. I. Some effects of preparative procedures on surface topography.
    Smith DC; Pilliar RM; Chernecky R
    J Biomed Mater Res; 1991 Sep; 25(9):1045-68. PubMed ID: 1663951
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The surface characteristics produced by various oral hygiene instruments and materials on titanium implant abutments.
    Rapley JW; Swan RH; Hallmon WW; Mills MP
    Int J Oral Maxillofac Implants; 1990; 5(1):47-52. PubMed ID: 2202669
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of modifying and veneering the surface of ceramic abutments on cellular attachment and proliferation.
    Mustafa K; Wennerberg A; Arvidson K; Messelt EB; Haag P; Karlsson S
    Clin Oral Implants Res; 2008 Nov; 19(11):1178-87. PubMed ID: 18983322
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 25.