These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 11322921)

  • 21. Transcatheter device closure of patent ductus arteriosus.
    Sultan M; Ullah M; Sadiq N; Akhtar K; Akbar H
    J Coll Physicians Surg Pak; 2014 Oct; 24(10):710-3. PubMed ID: 25327911
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Transcatheter closure of secundum atrial septal defect in children].
    Gao W; Zhou AQ; Yu ZQ; Li F; Zhang YQ; Sun K; Zhong YM
    Zhonghua Er Ke Za Zhi; 2004 Apr; 42(4):287-90. PubMed ID: 15157392
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Interventional pediatric cardiology: device closures.
    Wilkinson JL
    Indian J Pediatr; 2000 Mar; 67(3 Suppl):S30-6. PubMed ID: 11129918
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transcatheter Closure of Patent Ductus Arteriosus: The Penang Hospital's Experience.
    Amir Hamzah AR; Tiow CA; Koh GT; Sharifah AM
    Med J Malaysia; 2011 Mar; 66(1):19-21. PubMed ID: 23765137
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transcatheter closure of patent ductus arteriosus: past, present and future.
    Baruteau AE; Hascoët S; Baruteau J; Boudjemline Y; Lambert V; Angel CY; Belli E; Petit J; Pass R
    Arch Cardiovasc Dis; 2014 Feb; 107(2):122-32. PubMed ID: 24560920
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Advantages and disadvantages of coils for transcatheter closure of patent ductus arteriosus.
    Galal MO
    J Interv Cardiol; 2003 Apr; 16(2):157-63. PubMed ID: 12768920
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transcatheter closure of patent ductus arteriosus with the use of Rashkind occluders and/or Gianturco coils: long-term follow-up in 123 patients and special reference to comparison, residual shunts, complications, and technique.
    Janorkar S; Goh T; Wilkinson J
    Am Heart J; 1999 Dec; 138(6 Pt 1):1176-83. PubMed ID: 10577450
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results.
    Hijazi ZM; Geggel RL
    Heart; 1996 Dec; 76(6):536-40. PubMed ID: 9014805
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transcatheter closure of residual patent ductus arteriosus shunting after the Rashkind occluder device using single or multiple Gianturco coils.
    Hijazi ZM; Geggel RL; al-Fadley F
    Cathet Cardiovasc Diagn; 1995 Nov; 36(3):255-8. PubMed ID: 8542636
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Transcatheter occlusion of patent ductus arteriosus in a preterm infant and review of literatures].
    Zhou K; Tang J; Hua Y; Shi X; Wang Y; Qiao L; Wang X; Mu D
    Zhonghua Er Ke Za Zhi; 2016 Jan; 54(1):43-6. PubMed ID: 26791923
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transcatheter closure of a patent ductus arteriosus in an elderly patient with the Gianturco-Grifka vascular occlusion device.
    Befeler B; Justiniano A; Zahn E
    Clin Cardiol; 2000 Oct; 23(10):790-1. PubMed ID: 11061061
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Right aortic arch with isolation of the left subclavian artery, moderate patent ductus arteriosus, and subclavian steal syndrome: A rare aortic arch anomaly treated with the Gianturco-Grifka vascular occlusion device.
    Jones TK; Garabedian H; Grifka RG
    Catheter Cardiovasc Interv; 1999 Jul; 47(3):320-2. PubMed ID: 10402288
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Relief of factitious coarctation following occlusion of large patent ductus arteriosus with Gianturco-Grifka vascular occluder.
    Ing FF; Mullins CE; Wolfe SB; Grifka RG
    Cathet Cardiovasc Diagn; 1998 Dec; 45(4):409-12. PubMed ID: 9863747
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients.
    Garay FJ; Aguirre D; Cárdenas L; Springmuller D; Heusser F
    J Interv Cardiol; 2015 Apr; 28(2):198-204. PubMed ID: 25832322
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter closure of large patent ductus arteriosus using custom made devices.
    Rohit MK; Gupta A
    Catheter Cardiovasc Interv; 2017 May; 89(6):E194-E199. PubMed ID: 24323820
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device.
    Philip R; Waller BR; Agrawal V; Wright D; Arevalo A; Zurakowski D; Sathanandam S
    Catheter Cardiovasc Interv; 2016 Feb; 87(2):310-7. PubMed ID: 26525611
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Impact of transcatheter occlusion of a patent ductus arteriosus on atrial septal defect diameter in children.
    Stapleton GE; Eidem BW; Pignatelli RH; Carlson KM; Mullins CE; Grifka RG
    Congenit Heart Dis; 2006 May; 1(3):116-9. PubMed ID: 18377555
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcatheter closure of the patient ductus arteriosus in adults using the Gianturco coil.
    Ing FF; Mullins CE; Rose M; Shapir Y; Bierman FZ
    Clin Cardiol; 1996 Nov; 19(11):875-9. PubMed ID: 8914781
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transcatheter occlusion of the patent ductus arteriosus with a single device technique: comparison between the Cook detachable coil and the Rashkind umbrella device.
    Jaeggi ET; Fasnacht M; Arbenz U; Beghetti M; Bauersfeld U; Friedli B
    Int J Cardiol; 2001 Jun; 79(1):71-6. PubMed ID: 11399343
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants.
    Schwartz MC; Nykanen D; Winner LH; Perez J; McMahan M; Munro HM; Suguna Narasimhulu S
    Congenit Heart Dis; 2016 Dec; 11(6):647-655. PubMed ID: 27225896
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.