These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 11323819)

  • 1. Simple linear formulation for magnetostimulation specific to MRI gradient coils.
    Chronik BA; Rutt BK
    Magn Reson Med; 2001 May; 45(5):916-9. PubMed ID: 11323819
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison between human magnetostimulation thresholds in whole-body and head/neck gradient coils.
    Chronik BA; Rutt BK
    Magn Reson Med; 2001 Aug; 46(2):386-94. PubMed ID: 11477644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetostimulation in MRI.
    Irnich W; Schmitt F
    Magn Reson Med; 1995 May; 33(5):619-23. PubMed ID: 7596265
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of peripheral axon geometry and local anatomy on magnetostimulation chronaxie.
    Ferris NG; Klein V; Guerin B; Wald LL; Davids M
    J Neural Eng; 2024 Jun; 21(3):. PubMed ID: 38806036
    [No Abstract]   [Full Text] [Related]  

  • 5. Prediction of peripheral nerve stimulation thresholds of MRI gradient coils using coupled electromagnetic and neurodynamic simulations.
    Davids M; Guérin B; Vom Endt A; Schad LR; Wald LL
    Magn Reson Med; 2019 Jan; 81(1):686-701. PubMed ID: 30094874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimizing electric fields and increasing peripheral nerve stimulation thresholds using a body gradient array coil.
    Babaloo R; Atalar E
    Magn Reson Med; 2024 Sep; 92(3):1290-1305. PubMed ID: 38624032
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental determination of human peripheral nerve stimulation thresholds in a 3-axis planar gradient system.
    Feldman RE; Hardy CJ; Aksel B; Schenck J; Chronik BA
    Magn Reson Med; 2009 Sep; 62(3):763-70. PubMed ID: 19526504
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Peripheral nerve stimulation properties of head and body gradient coils of various sizes.
    Zhang B; Yen YF; Chronik BA; McKinnon GC; Schaefer DJ; Rutt BK
    Magn Reson Med; 2003 Jul; 50(1):50-8. PubMed ID: 12815678
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Peripheral nerve stimulation limits of a high amplitude and slew rate magnetic field gradient coil for neuroimaging.
    Tan ET; Hua Y; Fiveland EW; Vermilyea ME; Piel JE; Park KJ; Ho VB; Foo TKF
    Magn Reson Med; 2020 Jan; 83(1):352-366. PubMed ID: 31385628
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of pulse duration on magnetostimulation thresholds.
    Saritas EU; Goodwill PW; Conolly SM
    Med Phys; 2015 Jun; 42(6):3005-12. PubMed ID: 26127053
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the threshold for peripheral nerve stimulation during gradient switching in whole body MR systems.
    Den Boer JA; Bourland JD; Nyenhuis JA; Ham CL; Engels JM; Hebrank FX; Frese G; Schaefer DJ
    J Magn Reson Imaging; 2002 May; 15(5):520-5. PubMed ID: 11997892
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anatomical measurements correlate with individual magnetostimulation thresholds for kHz-range homogeneous magnetic fields.
    Demirel OB; Kilic T; Çukur T; Saritas EU
    Med Phys; 2020 Apr; 47(4):1836-1844. PubMed ID: 31958146
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The discrepancy between human peripheral nerve chronaxie times as measured using magnetic and electric field stimuli: the relevance to MRI gradient coil safety.
    Recoskie BJ; Scholl TJ; Chronik BA
    Phys Med Biol; 2009 Oct; 54(19):5965-79. PubMed ID: 19759411
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils.
    Chronik BA; Ramachandran M
    J Magn Reson Imaging; 2003 Jun; 17(6):716-21. PubMed ID: 12766901
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.
    Klein V; Davids M; Schad LR; Wald LL; Guérin B
    Magn Reson Med; 2021 Feb; 85(2):1047-1061. PubMed ID: 32812280
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comments on 'the discrepancy between human peripheral nerve chronaxie times as measured using magnetic and electric field stimuli: the relevance to MRI gradient coil safety'.
    Patrick Reilly J
    Phys Med Biol; 2010 Feb; 55(4):L5-8. PubMed ID: 20124652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The modular (twin) gradient coil--high resolution, high contrast, diffusion weighted EPI at 1.0 Tesla.
    Harvey PR
    MAGMA; 1999 Mar; 8(1):43-7. PubMed ID: 10383092
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensory and motor stimulation thresholds of the ulnar nerve from electric and magnetic field stimuli: implications to gradient coil operation.
    Recoskie BJ; Scholl TJ; Zinke-Allmang M; Chronik BA
    Magn Reson Med; 2010 Dec; 64(6):1567-79. PubMed ID: 20939088
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Peripheral nerve stimulation characteristics of an asymmetric head-only gradient coil compatible with a high-channel-count receiver array.
    Lee SK; Mathieu JB; Graziani D; Piel J; Budesheim E; Fiveland E; Hardy CJ; Tan ET; Amm B; Foo TK; Bernstein MA; Huston J; Shu Y; Schenck JF
    Magn Reson Med; 2016 Dec; 76(6):1939-1950. PubMed ID: 26628078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging.
    So PP; Stuchly MA; Nyenhuis JA
    IEEE Trans Biomed Eng; 2004 Nov; 51(11):1907-14. PubMed ID: 15536892
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.