132 related articles for article (PubMed ID: 11323978)
1. Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups.
Affatato S; Vandelli C; Bordini B; Toni A
Proc Inst Mech Eng H; 2001; 215(1):107-11. PubMed ID: 11323978
[TBL] [Abstract][Full Text] [Related]
2. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study.
McKellop H; Shen FW; Lu B; Campbell P; Salovey R
J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644
[TBL] [Abstract][Full Text] [Related]
3. In vivo change of elastic property in polyethylene acetabular components.
Kusaba A; Kondo S; Mori Y; Kuroki Y
Mod Rheumatol; 2008; 18(2):140-5. PubMed ID: 18292965
[TBL] [Abstract][Full Text] [Related]
4. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide.
Ries MD; Weaver K; Rose RM; Gunther J; Sauer W; Beals N
Clin Orthop Relat Res; 1996 Dec; (333):87-95. PubMed ID: 8981884
[TBL] [Abstract][Full Text] [Related]
5. Fluid-sorption phenomena in sterilized polyethylene acetabular prostheses.
Clarke IC; Starkebaum W; Hosseinian A; McGuire P; Okuda R; Salovey R; Young R
Biomaterials; 1985 May; 6(3):184-8. PubMed ID: 4005362
[TBL] [Abstract][Full Text] [Related]
6. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.
McKellop HA; Shen FW; Campbell P; Ota T
J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720
[TBL] [Abstract][Full Text] [Related]
7. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator.
Affatato S; Bordini B; Fagnano C; Taddei P; Tinti A; Toni A
Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439
[TBL] [Abstract][Full Text] [Related]
8. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips.
Digas G; Thanner J; Nivbrant B; Röhrl S; Ström H; Kärrholm J
Acta Orthop Scand; 2003 Oct; 74(5):531-41. PubMed ID: 14620972
[TBL] [Abstract][Full Text] [Related]
9. The performance of gamma- and EtO-sterilised UHWMPE acetabular cups tested under severe simulator conditions. Part 1: role of the third-body wear process.
Affatato S; Bersaglia G; Foltran I; Taddei P; Fini G; Toni A
Biomaterials; 2002 Dec; 23(24):4839-46. PubMed ID: 12361624
[TBL] [Abstract][Full Text] [Related]
10. Determination of the activation energies of and aggregate rates for exothermic physico-chemical changes in UHMWPE by isothermal heat-conduction microcalorimetry (IHCMC).
Hardison A; Lewis G; Daniels AU; Smith RA
Biomaterials; 2003 Dec; 24(28):5145-51. PubMed ID: 14568431
[TBL] [Abstract][Full Text] [Related]
11. Effects of sterilization with hydrogen peroxide gas plasma, ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints.
Gatineau M; El-Warrak AO; Bolliger C; Mourez M; Berthiaume F
Am J Vet Res; 2012 Oct; 73(10):1665-9. PubMed ID: 23013195
[TBL] [Abstract][Full Text] [Related]
12. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
Saikko V; Calonius O; Keränen J
J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
[TBL] [Abstract][Full Text] [Related]
13. Oxidation in Retrieved, Never-Irradiated UHMWPE Bearings: What Can We Learn About in Vivo Oxidation?
Currier BH; Jevsevar KC; Van Citters DW
J Bone Joint Surg Am; 2023 Feb; 105(4):293-301. PubMed ID: 36730084
[TBL] [Abstract][Full Text] [Related]
14. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.
McKellop H; Shen FW; Lu B; Campbell P; Salovey R
J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831
[TBL] [Abstract][Full Text] [Related]
15. Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups.
Jedenmalm A; Affatato S; Taddei P; Leardini W; Gedde UW; Fagnano C; Viceconti M
J Biomed Mater Res A; 2009 Sep; 90(4):1032-42. PubMed ID: 18671264
[TBL] [Abstract][Full Text] [Related]
16. Effects of sterilization on poly(ethylene glycol) hydrogels.
Kanjickal D; Lopina S; Evancho-Chapman MM; Schmidt S; Donovan D
J Biomed Mater Res A; 2008 Dec; 87(3):608-17. PubMed ID: 18186054
[TBL] [Abstract][Full Text] [Related]
17. Conventional ultra-high molecular weight polyethylene: a gold standard of sorts.
Engh CA; Sychterz CJ; Engh CA
Instr Course Lect; 2005; 54():183-7. PubMed ID: 15948445
[TBL] [Abstract][Full Text] [Related]
18. [Effects of different sterilization procedures on degree of oxidation of ultra-high molecular weight polyethylene].
Jerosch J; Fuchs S; Liljenqvist U; Haftka A
Biomed Tech (Berl); 1995 Oct; 40(10):296-303. PubMed ID: 8527642
[TBL] [Abstract][Full Text] [Related]
19. Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.
Ayers DC; Greene M; Snyder B; Aubin M; Drew J; Bragdon C
J Bone Joint Surg Am; 2015 Apr; 97(8):627-34. PubMed ID: 25878306
[TBL] [Abstract][Full Text] [Related]
20. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator.
Taddei P; Affatato S; Fagnano C; Toni A
Biomacromolecules; 2006 Jun; 7(6):1912-20. PubMed ID: 16768414
[TBL] [Abstract][Full Text] [Related]