122 related articles for article (PubMed ID: 11330512)
1. Use of a Fogarty catheter to open an incompletely expanded Vena Tech-LGM vena cava filter--a case report.
Danikas D; Constantinopoulous GS; Stratoulias C; Ginalis EM
Angiology; 2001 Apr; 52(4):283-6. PubMed ID: 11330512
[TBL] [Abstract][Full Text] [Related]
2. In vitro flow phantom analysis and clot-capturing ability of incompletely opened Vena Tech-LGM vena caval filters.
Korbin CD; Reed RA; Taylor FC; Kokoris SP; Teitelbaum GP
Cardiovasc Intervent Radiol; 1993; 16(1):3-6. PubMed ID: 8435832
[TBL] [Abstract][Full Text] [Related]
3. Incomplete deployment of the Vena Tech LP filter--case series and concerns.
Contractor S; Esmaeili A; Reina D; Deitch E
Vasc Endovascular Surg; 2011 May; 45(4):345-51. PubMed ID: 21527468
[TBL] [Abstract][Full Text] [Related]
4. Manipulation by catheter of unopened LGM filter.
Isaacson S; Gray RR; Pugash RA
Can Assoc Radiol J; 1993 Jun; 44(3):217-20. PubMed ID: 8504338
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the LGM Vena-Tech infrarenal vena cava filter in an ovine venous thromboembolism model.
Crochet D; Grossetête R; Bach-Lijour B; Larguier L; Le Nihouannen JC
J Vasc Interv Radiol; 2001 Jun; 12(6):739-45. PubMed ID: 11389226
[TBL] [Abstract][Full Text] [Related]
6. Stenting of chronically obstructed inferior vena cava filters.
Neglén P; Oglesbee M; Olivier J; Raju S
J Vasc Surg; 2011 Jul; 54(1):153-61. PubMed ID: 21316900
[TBL] [Abstract][Full Text] [Related]
7. Long-term follow-up of Vena Tech-LGM filter: predictors and frequency of caval occlusion.
Crochet DP; Brunel P; Trogrlic S; Grossetëte R; Auget JL; Dary C
J Vasc Interv Radiol; 1999 Feb; 10(2 Pt 1):137-42. PubMed ID: 10082099
[TBL] [Abstract][Full Text] [Related]
8. Technical factors affecting the accuracy of bedside IVC filter placement using intravascular ultrasound.
Hodgkiss-Harlow K; Back MR; Brumberg R; Armstrong P; Shames M; Johnson B; Bandyk DF
Vasc Endovascular Surg; 2012 May; 46(4):293-9. PubMed ID: 22544870
[TBL] [Abstract][Full Text] [Related]
9. Incomplete opening of LGM (Vena Tech) filters inserted via the transjugular approach.
Reed RA; Teitelbaum GP; Taylor FC; Vogelzang RC; Yedlicka JW; Pentecost MJ; Castaneda-Zuniga WR; Amplatz K
J Vasc Interv Radiol; 1991 Nov; 2(4):441-5. PubMed ID: 1797209
[TBL] [Abstract][Full Text] [Related]
10. Oversized inferior vena cava: use of a single Vena Tech--LGM filter.
Millward SF; Aquino J; Peterson RA
Can Assoc Radiol J; 1996 Aug; 47(4):272-4. PubMed ID: 8696995
[TBL] [Abstract][Full Text] [Related]
11. Use of Wall stent to exclude a thrombosed inferior vena cava filter.
Golarz SR; Grimsley B
Ann Vasc Surg; 2010 Jul; 24(5):690.e5-7. PubMed ID: 20144530
[TBL] [Abstract][Full Text] [Related]
12. Retrieval of a malpositioned vena cava filter with embolic protection with use of a second filter.
Yavuz K; Geyik S; Barton RE; Kaufman JA
J Vasc Interv Radiol; 2005 Apr; 16(4):531-4. PubMed ID: 15802453
[TBL] [Abstract][Full Text] [Related]
13. A new self-convertible inferior vena cava filter: experimental in-vitro and in-vivo evaluation.
Gao X; Zhang J; Chen B; Yu H; Li J; Zhang S; Feng Z; Ye L; Han J
J Vasc Interv Radiol; 2011 Jun; 22(6):829-34. PubMed ID: 21530312
[TBL] [Abstract][Full Text] [Related]
14. Iliac Vein Stent Fracture Due to a Migrated Retrievable Vena Cava Filter.
Yim NY; Kim JK; Kim HO; Kang YJ; Jung HD
Vasc Endovascular Surg; 2016 Feb; 50(2):94-7. PubMed ID: 26912396
[TBL] [Abstract][Full Text] [Related]
15. Complex Inferior Vena Cava Filter Removal with a Metallic Bladed-Tip Mechanical Sheath.
Wadhwani A; Bandali M; Farrell J; Kuriachan V; Herget E
J Vasc Interv Radiol; 2016 Nov; 27(11):1726-1727. PubMed ID: 27926398
[No Abstract] [Full Text] [Related]
16. Iatrogenic migration of VenaTech LP IVC filter to superior vena cava secondary to guidewire entrapment: case report and review of literature.
Almestady R; Spain J; Bayona-Molano Mdel P; Wang W
Vasc Endovascular Surg; 2013 Jan; 47(1):48-50. PubMed ID: 23203598
[TBL] [Abstract][Full Text] [Related]
17. Vena Tech LGM filter retrieval 16 years after implantation: piecemeal removal by intentional mechanical fracture.
Kuo WT; Deso SE; Robertson SW
J Vasc Interv Radiol; 2013 Nov; 24(11):1731-7. PubMed ID: 24160825
[TBL] [Abstract][Full Text] [Related]
18. Inferior vena cava filter from left-sided superior vena cava.
Nair S; Ettles D; Robinson G; Scott P
Cardiovasc Intervent Radiol; 2008 Jul; 31 Suppl 2():S171-3. PubMed ID: 17882483
[TBL] [Abstract][Full Text] [Related]
19. The Vena Tech filter: evaluation of a new inferior vena cava interruption device.
Cull DL; Wheeler JR; Gregory RT; Synder SO; Gayle RG; Parent FN
J Cardiovasc Surg (Torino); 1991; 32(5):691-6. PubMed ID: 1939334
[TBL] [Abstract][Full Text] [Related]
20. Retrospective Review of 516 Implantations of Option Inferior Vena Cava Filters at a Single Health Care System.
Tsui B; An T; Moon E; King R; Wang W
J Vasc Interv Radiol; 2016 Mar; 27(3):345-53. PubMed ID: 26826941
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]