1. Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling. Boellaard R; van Lingen A; Lammertsma AA J Nucl Med; 2001 May; 42(5):808-17. PubMed ID: 11337581 [TBL] [Abstract][Full Text] [Related]
2. Postinjection transmission scanning in myocardial 18F-FDG PET studies using both filtered backprojection and iterative reconstruction. van der Weerdt AP; Boellaard R; Knaapen P; Visser CA; Lammertsma AA; Visser FC J Nucl Med; 2004 Feb; 45(2):169-75. PubMed ID: 14960632 [TBL] [Abstract][Full Text] [Related]
3. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment. Riddell C; Carson RE; Carrasquillo JA; Libutti SK; Danforth DN; Whatley M; Bacharach SL J Nucl Med; 2001 Sep; 42(9):1316-23. PubMed ID: 11535719 [TBL] [Abstract][Full Text] [Related]
4. Quantitative comparison of analytic and iterative reconstruction methods in 2- and 3-dimensional dynamic cardiac 18F-FDG PET. Lubberink M; Boellaard R; van der Weerdt AP; Visser FC; Lammertsma AA J Nucl Med; 2004 Dec; 45(12):2008-15. PubMed ID: 15585474 [TBL] [Abstract][Full Text] [Related]
5. Effects of iterative reconstruction on image contrast and lesion detection in gamma camera coincidence imaging in lung and breast cancers. Paul AK; Tatsumi M; Yutani K; Fujino K; Hashikawa K; Nishimura T Nucl Med Commun; 2002 Jan; 23(1):103-10. PubMed ID: 11748445 [TBL] [Abstract][Full Text] [Related]
6. Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization. Morimoto T; Ito H; Takano A; Ikoma Y; Seki C; Okauchi T; Tanimoto K; Ando A; Shiraishi T; Yamaya T; Suhara T Ann Nucl Med; 2006 Apr; 20(3):237-43. PubMed ID: 16715957 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph. van Velden FH; Kloet RW; van Berckel BN; Lammertsma AA; Boellaard R J Nucl Med; 2009 Jan; 50(1):72-80. PubMed ID: 19091902 [TBL] [Abstract][Full Text] [Related]
8. Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study. Gutman F; Gardin I; Delahaye N; Rakotonirina H; Hitzel A; Manrique A; Le Guludec D; Véra P Eur J Nucl Med Mol Imaging; 2003 Nov; 30(11):1510-9. PubMed ID: 14579091 [TBL] [Abstract][Full Text] [Related]
9. Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging. Lartizien C; Kinahan PE; Swensson R; Comtat C; Lin M; Villemagne V; Trébossen R J Nucl Med; 2003 Feb; 44(2):276-90. PubMed ID: 12571221 [TBL] [Abstract][Full Text] [Related]
10. Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PET. Visvikis D; Cheze-LeRest C; Costa DC; Bomanji J; Gacinovic S; Ell PJ Eur J Nucl Med; 2001 Sep; 28(9):1326-35. PubMed ID: 11585291 [TBL] [Abstract][Full Text] [Related]
12. Comparison of different types of commercial filtered backprojection and ordered-subset expectation maximization SPECT reconstruction software. Seret A; Forthomme J J Nucl Med Technol; 2009 Sep; 37(3):179-87. PubMed ID: 19726808 [TBL] [Abstract][Full Text] [Related]
13. Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals. Cheng JC; Shoghi K; Laforest R Med Phys; 2012 Feb; 39(2):1029-41. PubMed ID: 22320813 [TBL] [Abstract][Full Text] [Related]
14. Is iterative reconstruction an alternative to filtered backprojection in routine processing of dopamine transporter SPECT studies? Koch W; Hamann C; Welsch J; Pöpperl G; Radau PE; Tatsch K J Nucl Med; 2005 Nov; 46(11):1804-11. PubMed ID: 16269593 [TBL] [Abstract][Full Text] [Related]
15. Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT. Lee YS; Kim JS; Kim KM; Kang JH; Lim SM; Kim HJ Ann Nucl Med; 2014 May; 28(4):340-8. PubMed ID: 24504938 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET. Søndergaard HM; Madsen MM; Boisen K; Bøttcher M; Schmitz O; Nielsen TT; Bøtker HE; Hansen SB Eur J Nucl Med Mol Imaging; 2007 Mar; 34(3):320-9. PubMed ID: 17033850 [TBL] [Abstract][Full Text] [Related]
17. Impact of acquisition geometry, image processing, and patient size on lesion detection in whole-body 18F-FDG PET. El Fakhri G; Santos PA; Badawi RD; Holdsworth CH; Van Den Abbeele AD; Kijewski MF J Nucl Med; 2007 Dec; 48(12):1951-60. PubMed ID: 18006613 [TBL] [Abstract][Full Text] [Related]
18. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images. Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145 [TBL] [Abstract][Full Text] [Related]
19. PET based volume segmentation with emphasis on the iterative TrueX algorithm. Knäusl B; Hirtl A; Dobrozemsky G; Bergmann H; Kletter K; Dudczak R; Georg D Z Med Phys; 2012 Feb; 22(1):29-39. PubMed ID: 21251804 [TBL] [Abstract][Full Text] [Related]
20. The SRT reconstruction algorithm for semiquantification in PET imaging. Kastis GA; Gaitanis A; Samartzis AP; Fokas AS Med Phys; 2015 Oct; 42(10):5970-82. PubMed ID: 26429272 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]