These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 11341752)

  • 1. Regional reference values for some quantities measured with the ADVIA Centaur analyser. A model of co-operation between the in vitro diagnostic industry and clinical laboratories.
    Ferré-Masferrer M; Fuentes-Arderiu X; Gomà-Llongueras M; Alumà-Trullàs A; Aramendi-Ramos M; Castaño-Vidriales JL; Esteban-Salan M; Graells-Ferrer M; Jiménez-González A; Jiménez-Lobo C; López-Esparza M; Parés-Pollán L; Regulez-Uranga M; Riesco-Prieto M; Rodríguez-Camba A; Vidal-Martínez J
    Clin Chem Lab Med; 2001 Feb; 39(2):166-9. PubMed ID: 11341752
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicentric reference values for some quantities measured with the Elecsys 2010 analyser.
    Fuentes-Arderiu X; Ferrer-Masferrer M; González-Alba JM; Villarino-González MI; Arrimadas-Esteban E; Cabrero-Olivé D; Cándenas-Arroyo M; García-García D; García-Lario JV; Idoate-Cervantes I; León-López C; López-Lazareno N; Mar-Medina C; Martí-Marcet I; Mauri-Dot M; Pérez-Valero V; Reta-Manterola A; Sánchez-Eixeres MR
    Clin Chim Acta; 2001 Feb; 304(1-2):143-6. PubMed ID: 11165210
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multicentric reference values for some quantities measured with Tina-Quant reagents systems and RD/Hitachi analysers.
    Fuentes-Arderiu X; Ferré-Masferrer M; González-Alba JM; Escolà-Aliberas J; Balsells-Rosello D; Blanco-Cristobal C; González-Cruz E; Ibarz-Escuer M; Latorre-Marcellán P; Lugo-Arocena J; Mar-Medina C; Muros-de-Fuentes M; Vicens-Manero M
    Scand J Clin Lab Invest; 2001 Jul; 61(4):273-6. PubMed ID: 11465340
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reference intervals for serum thyrotropin, free thyroxine and free triiodothyronine in healthy adults in Finland, measured by an immunoautomate based on time-resolved fluorescence (AutoDELFIA).
    Taimela E; Kairisto V; Koskinen P; Leino A; Irjala K
    Eur J Clin Chem Clin Biochem; 1997 Nov; 35(11):889-90. PubMed ID: 9426351
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multicentric reference values: shared reference limits.
    Ferré-Masferrer M; Fuentes-Arderiu X; Alvarez-Funes V; Güell-Miró R; Castiñeiras-Lacambra MJ
    Eur J Clin Chem Clin Biochem; 1997 Sep; 35(9):715-8. PubMed ID: 9352235
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multicentre physiological reference values for some urinary component-to-creatinine (creatininium) concentration ratios.
    Fuentes-Arderiu X; Mas-Serra R; de-Nó-Lengaran C; Espejo-López F; Filgueiras-Martínez P; Gassiot-Cordomí P; Idoate-Cervantes I; Poncela-García MV; Porras-Gracia J; Sanz-Lobo I; Viloria-Peñas Mdel M; Juvé-Cuxart S
    Clin Chem Lab Med; 2005; 43(9):958-62. PubMed ID: 16176177
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous age-dependent reference ranges for thyroid hormones in neonates, infants, children and adolescents established using the ADVIA Centaur Analyzer.
    Hübner U; Englisch C; Werkmann H; Butz H; Georgs T; Zabransky S; Herrmann W
    Clin Chem Lab Med; 2002 Oct; 40(10):1040-7. PubMed ID: 12476946
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Necessity to define thyroid reference values for better clinical interpretation].
    Plouvier E; Alliot L; Bigorie B; Kowalski C; Medeau V; Thuillier F
    Ann Biol Clin (Paris); 2011; 69(1):77-83. PubMed ID: 21463999
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.
    Kristensen GB; Rustad P; Berg JP; Aakre KM
    Clin Chem; 2016 Sep; 62(9):1255-63. PubMed ID: 27384539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparability of five analytical systems for the determination of triiodothyronine, thyroxine and thyroid-stimulating hormone.
    Zhou Q; Li S; Li X; Wang W; Wang Z
    Clin Chem Lab Med; 2006; 44(11):1363-6. PubMed ID: 17087650
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thyroid-stimulating hormone and free thyroxine on the ADVIA Centaur immunoassay system: a multicenter assessment of analytical performance.
    Reix N; Massart C; d'Herbomez M; Gasser F; Heurtault B; Agin A
    Clin Biochem; 2013 Sep; 46(13-14):1305-8. PubMed ID: 23628596
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Decision limit for troponin I on ADVIA:Centaur and evaluation of the analytical precision at low concentrations.
    Fortunato A; Giavarina D
    Clin Lab; 2003; 49(5-6):251-3. PubMed ID: 15285182
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reference intervals from birth to adulthood for serum thyroxine (T4), triiodothyronine (T3), free T3, free T4, thyroxine binding globulin (TBG) and thyrotropin (TSH).
    Elmlinger MW; Kühnel W; Lambrecht HG; Ranke MB
    Clin Chem Lab Med; 2001 Oct; 39(10):973-9. PubMed ID: 11758614
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An approach to establish reference intervals for thyrotropin in pregnancy using the ADVIA Centaur analyzer.
    Dorizzi RM; Ozzola G; Sommella C; Catania F; Lelli F; Migali E; Polverini G
    Clin Lab; 2010; 56(9-10):417-25. PubMed ID: 21086787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of serum total thyroxine, triiodothyronine, free thyroxine, and thyrotropin concentrations for diagnosis of hypothyroidism in dogs.
    Peterson ME; Melián C; Nichols R
    J Am Vet Med Assoc; 1997 Dec; 211(11):1396-402. PubMed ID: 9394888
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Reference values for the concentrations of triiodothyronine, thyroxine and thyrotropin in the blood serum of euthyroid children. Method: luminescence-enhanced enzyme immunoassay].
    Liappis N; Schlebusch H
    Klin Padiatr; 1988; 200(5):410-3. PubMed ID: 3054265
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Indirect reference intervals of plasma and serum thyrotropin (TSH) concentrations from intra-laboratory data bases from several German and Italian medical centres.
    Arzideh F; Wosniok W; Haeckel R
    Clin Chem Lab Med; 2011 Apr; 49(4):659-64. PubMed ID: 21342020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. "Good samples make good assays" – the problem of sourcing clinical samples for a standardization project.
    Van Houcke SK; Thienpont LM
    Clin Chem Lab Med; 2013 May; 51(5):967-72. PubMed ID: 23045383
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Error in laboratory reference limits as shown in a collaborative quality-assurance program.
    Compton PJ; Stuart MC; Lazarus L
    Clin Chem; 1986 May; 32(5):845-9. PubMed ID: 3516451
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of a panel of sera for the alignment of test results in the worldwide multicenter study on reference values.
    Ichihara K; Ozarda Y; Klee G; Straseski J; Baumann N; Ishikura K;
    Clin Chem Lab Med; 2013 May; 51(5):1007-25. PubMed ID: 23633468
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.