These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 11353926)

  • 1. Glucowatch Biographer: a noninvasive glucose monitoring device.
    Med Lett Drugs Ther; 2001 May; 43(1104):42. PubMed ID: 11353926
    [No Abstract]   [Full Text] [Related]  

  • 2. GlucoWatch Biographer. An automatic, noninvasive glucose monitor.
    Health Devices; 2002 Aug; 31(8):295-302. PubMed ID: 12530360
    [No Abstract]   [Full Text] [Related]  

  • 3. The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor.
    Tierney MJ; Tamada JA; Potts RO; Eastman RC; Pitzer K; Ackerman NR; Fermi SJ
    Ann Med; 2000 Dec; 32(9):632-41. PubMed ID: 11209971
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Choosing a blood glucose meter.
    Spollett GR
    Diabetes Self Manag; 2003; 20(4):99-100, 102-6. PubMed ID: 12908446
    [No Abstract]   [Full Text] [Related]  

  • 5. Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes.
    Tierney MJ; Tamada JA; Potts RO; Jovanovic L; Garg S;
    Biosens Bioelectron; 2001 Dec; 16(9-12):621-9. PubMed ID: 11679237
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Glucose meters. A guide for you and your patients.
    Holcomb ME; Bjorkman C
    Adv Nurse Pract; 2007 Jul; 15(7):45-8. PubMed ID: 19998995
    [No Abstract]   [Full Text] [Related]  

  • 7. Results of continuous glucose monitoring by GlucoWatch Biographer in a cohort of diabetic children and adolescents under real-life conditions.
    Bozzetti V; Viscardi M; Bonfanti R; Azzinari A; Meschi F; Bognetti E; Chiumello G
    Pediatr Diabetes; 2003 Mar; 4(1):57-8. PubMed ID: 14655524
    [No Abstract]   [Full Text] [Related]  

  • 8. Glucose monitoring by reverse iontophoresis.
    Potts RO; Tamada JA; Tierney MJ
    Diabetes Metab Res Rev; 2002; 18 Suppl 1():S49-53. PubMed ID: 11921430
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer.
    Tierney MJ; Garg S; Ackerman NR; Fermi SJ; Kennedy J; Lopatin M; Potts RO; Tamada JA
    Diabetes Technol Ther; 2000; 2(2):199-207. PubMed ID: 11469259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of the Cygnus GlucoWatch biographer at a diabetes camp.
    Gandrud LM; Paguntalan HU; Van Wyhe MM; Kunselman BL; Leptien AD; Wilson DM; Eastman RC; Buckingham BA
    Pediatrics; 2004 Jan; 113(1 Pt 1):108-11. PubMed ID: 14702457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Containment sensors: manufacture in technical production facilities--technical and economic aspects].
    Finke L
    Biomed Tech (Berl); 1998; 43 Suppl():582-3. PubMed ID: 9859500
    [No Abstract]   [Full Text] [Related]  

  • 12. Noninvasive glycaemia monitoring: background, traditional findings, and novelties in the recent clinical trials.
    Tura A
    Curr Opin Clin Nutr Metab Care; 2008 Sep; 11(5):607-12. PubMed ID: 18685457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of the GlucoWatch biographer in children and adolescents with diabetes.
    Eastman RC; Chase HP; Buckingham B; Hathout EH; Fuller-Byk L; Leptien A; Van Wyhe MM; Davis TL; Fermi SJ; Pechler H; Sahyun G; Lopatin M; Wang BY; Wei C; Bartkowiak M; Ginsberg BH; Tamada JA; Pitzer KR
    Pediatr Diabetes; 2002 Sep; 3(3):127-34. PubMed ID: 15016152
    [TBL] [Abstract][Full Text] [Related]  

  • 14. GlucoWatch approved for children with diabetes.
    FDA Consum; 2002; 36(6):6. PubMed ID: 12523287
    [No Abstract]   [Full Text] [Related]  

  • 15. Clinical chemistry and clinical toxicology devices advisory panel recommendation on Glucowatch.
    Klonoff DC
    Diabetes Technol Ther; 2000; 2(1):125-6. PubMed ID: 11467313
    [No Abstract]   [Full Text] [Related]  

  • 16. New transcutaneous sampling of glucose for patients with type II diabetes using an ion-sensitive field-effect transistor.
    Kayashima S; Arai T; Noritake M; Nagata N; Kikuchi M; Ito N; Matsumoto Y; Kaneyoshi A; Kimura J; Kuriyama T
    Clin Chim Acta; 1995 Aug; 240(1):11-9. PubMed ID: 8582056
    [No Abstract]   [Full Text] [Related]  

  • 17. Mouse-related dermatosis.
    Li JG; Feng YG; Feng J; Xiao SX
    Int J Dermatol; 2004 Nov; 43(11):855-6. PubMed ID: 15533074
    [No Abstract]   [Full Text] [Related]  

  • 18. Self-monitoring of blood glucose: a test for patients or health-care professionals?
    Bhatnagar D
    Ann Clin Biochem; 2009 Jul; 46(Pt 4):271-2. PubMed ID: 19654101
    [No Abstract]   [Full Text] [Related]  

  • 19. A better mousetrap: what's new in blood glucose monitoring?
    Cox M
    J Pediatr Health Care; 2002; 16(6):314-6. PubMed ID: 12436103
    [No Abstract]   [Full Text] [Related]  

  • 20. The effect of preapplication of corticosteroids on skin irritation and performance of the GlucoWatch G2 Biographer.
    Tamada JA; Davis TL; Leptien AD; Lee J; Wang B; Lopatin M; Wei C; Wilson D; Comyns K; Eastman RC
    Diabetes Technol Ther; 2004 Jun; 6(3):357-67. PubMed ID: 15198839
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.