BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 11359272)

  • 1. Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw: 1-year prospective study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2000; 2(1):2-9. PubMed ID: 11359272
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical experience of CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 3-year interim report.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2002; 4(2):104-9. PubMed ID: 12121610
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2004; 6(4):199-209. PubMed ID: 15841580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.
    Örtorp A; Jemt T
    Clin Implant Dent Relat Res; 2012 Mar; 14(1):88-99. PubMed ID: 19686283
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implant-supported welded titanium frameworks in the edentulous maxilla: a 5-year prospective multicenter study.
    Jemt T; Bergendal B; Arvidson K; Bergendal T; Karlsson LD; Linden B; Rundcrantz T; Wendelhag I
    Int J Prosthodont; 2002; 15(6):544-8. PubMed ID: 12475159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On titanium frameworks and alternative impression techniques in implant dentistry.
    Ortorp A
    Swed Dent J Suppl; 2005; (169):3-88. PubMed ID: 15709359
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Early laser-welded titanium frameworks supported by implants in the edentulous mandible: a 15-year comparative follow-up study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2009 Dec; 11(4):311-22. PubMed ID: 18783415
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.
    Ortorp A; Jemt T; Bäck T; Jälevik T
    Int J Prosthodont; 2003; 16(2):194-200. PubMed ID: 12737254
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 5-year follow-up study.
    Ortorp A; Linden B; Jemt T
    Int J Prosthodont; 1999; 12(1):65-72. PubMed ID: 10196830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Laser-welded titanium frameworks supported by implants in the partially edentulous mandible: a 10-year comparative follow-up study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2008 Sep; 10(3):128-39. PubMed ID: 18218053
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 10-year follow-up study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 2006; 8(4):198-209. PubMed ID: 17100745
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study.
    Jemt T; Henry P; Lindén B; Naert I; Weber H; Wendelhag I
    Int J Prosthodont; 2003; 16(4):415-21. PubMed ID: 12956498
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.
    Jemt T; Henry P; Lindén B; Naert I; Weber H; Bergström C
    Int J Prosthodont; 2000; 13(4):282-8. PubMed ID: 11203643
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laser-welded titanium frameworks supported by implants in the edentulous maxilla: a 2-year prospective multicenter study.
    Jemt T; Bergendal B; Arvidsson K; Bergendal T; Karlsson U; Linden B; Palmqvist S; Rundcrantz T; Bergström C
    Int J Prosthodont; 1998; 11(6):551-7. PubMed ID: 10023217
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study.
    Ortorp A; Jemt T
    Clin Implant Dent Relat Res; 1999; 1(2):84-91. PubMed ID: 11359302
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implant treatment in the edentulous maxillae: a 15-year follow-up study on 76 consecutive patients provided with fixed prostheses.
    Jemt T; Johansson J
    Clin Implant Dent Relat Res; 2006; 8(2):61-9. PubMed ID: 16774591
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks.
    Al-Fadda SA; Zarb GA; Finer Y
    Int J Prosthodont; 2007; 20(2):125-31. PubMed ID: 17455431
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implant-level prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use.
    Hjalmarsson L; Smedberg JI; Pettersson M; Jemt T
    Int J Prosthodont; 2011; 24(2):158-67. PubMed ID: 21479285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the marginal precision of one-piece complete arch titanium frameworks fabricated using five different methods for implant-supported restorations.
    Torsello F; di Torresanto VM; Ercoli C; Cordaro L
    Clin Oral Implants Res; 2008 Aug; 19(8):772-9. PubMed ID: 18720557
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the role of number of fixtures, surgical technique and timing of loading.
    Eliasson A
    Swed Dent J Suppl; 2008; (197):3-95. PubMed ID: 18652085
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.