216 related articles for article (PubMed ID: 11374449)
1. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.
Saikko V; Ahlroos T; Calonius O; Keränen J
Biomaterials; 2001 Jun; 22(12):1507-14. PubMed ID: 11374449
[TBL] [Abstract][Full Text] [Related]
2. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
[TBL] [Abstract][Full Text] [Related]
3. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
Saikko V; Calonius O; Keränen J
J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
[TBL] [Abstract][Full Text] [Related]
4. Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.
Hill MR; Catledge SA; Konovalov V; Clem WC; Chowdhury SA; Etheridge BS; Stanishevsky A; Lemons JE; Vohra YK; Eberhardt AW
J Biomed Mater Res B Appl Biomater; 2008 Apr; 85(1):140-8. PubMed ID: 17853416
[TBL] [Abstract][Full Text] [Related]
5. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
[TBL] [Abstract][Full Text] [Related]
6. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads.
Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E
Proc Inst Mech Eng H; 2002; 216(4):219-30. PubMed ID: 12206518
[TBL] [Abstract][Full Text] [Related]
7. Metal release from total hip articulations in vitro: substantial from CoCr/CoCr, negligible from CoCr/PE and alumina/PE.
Saikko V; Nevalainen J; Revitzer H; Ylinen P
Acta Orthop Scand; 1998 Oct; 69(5):449-54. PubMed ID: 9855223
[TBL] [Abstract][Full Text] [Related]
8. Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.
Roy ME; Whiteside LA; Magill ME; Katerberg BJ
Clin Orthop Relat Res; 2011 Aug; 469(8):2337-45. PubMed ID: 21312076
[TBL] [Abstract][Full Text] [Related]
9. Wear of polyethylene acetabular cups against alumina femoral heads. 5 prostheses compared in a hip simulator for 35 million walking cycles.
Saikko VO
Acta Orthop Scand; 1993 Oct; 64(5):507-12. PubMed ID: 8237313
[TBL] [Abstract][Full Text] [Related]
10. Wear behaviour of CFR PEEK articulated against CoCr under varying contact stresses: Low wear of CFR PEEK negated by wear of the CoCr counterface.
Kandemir G; Smith S; Joyce TJ
J Mech Behav Biomed Mater; 2019 Sep; 97():117-125. PubMed ID: 31108368
[TBL] [Abstract][Full Text] [Related]
11. An in vitro wear study of alumina-alumina total hip prostheses.
Smith SL; Unsworth A
Proc Inst Mech Eng H; 2001; 215(5):443-6. PubMed ID: 11726044
[TBL] [Abstract][Full Text] [Related]
12. Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator.
Saikko VO; Paavolainen PO; Slätis P
Acta Orthop Scand; 1993 Aug; 64(4):391-402. PubMed ID: 8213114
[TBL] [Abstract][Full Text] [Related]
13. The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations.
Phipatanakul WP; Johnson SA; Good V; Clarke IC
J Biomed Mater Res; 1998 Feb; 39(2):229-33. PubMed ID: 9457552
[TBL] [Abstract][Full Text] [Related]
14. Charnley wear model for validation of hip simulators--ball diameter versus polytetrafluoroethylene and polyethylene wear.
Clarke IC; Good V; Anissian L; Gustafson A
Proc Inst Mech Eng H; 1997; 211(1):25-36. PubMed ID: 9141888
[TBL] [Abstract][Full Text] [Related]
15. Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond.
Shishido T; Clarke IC; Williams P; Boehler M; Asano T; Shoji H; Masaoka T; Yamamoto K; Imakiire A
J Biomed Mater Res B Appl Biomater; 2003 Oct; 67(1):638-47. PubMed ID: 14528462
[TBL] [Abstract][Full Text] [Related]
16. A Morlet wavelet signal analysis with a Daubechies filter for the wear assessment of hip prostheses coated with diamond-like carbon by triboadhesion.
Rodríguez-Lelis JM; Mata DT; Vargas-Treviño M; Navarro-Torres J; Piña-Piña G; Abundez-Pliego A
J Appl Biomech; 2010 Aug; 26(3):273-80. PubMed ID: 20841618
[TBL] [Abstract][Full Text] [Related]
17. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
Lancaster JG; Dowson D; Isaac GH; Fisher J
Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
[TBL] [Abstract][Full Text] [Related]
18. Hip simulator wear testing according to the newly introduced standard ISO 14242.
Kaddick C; Wimmer MA
Proc Inst Mech Eng H; 2001; 215(5):429-42. PubMed ID: 11726043
[TBL] [Abstract][Full Text] [Related]
19. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
[TBL] [Abstract][Full Text] [Related]
20. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]