BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 11382073)

  • 1. Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion.
    Jagatia M; Jalali-Vahid D; Jin ZM
    Proc Inst Mech Eng H; 2001; 215(2):141-52. PubMed ID: 11382073
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion.
    Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2001; 215(6):531-41. PubMed ID: 11848385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prediction of lubricating film thickness in UHMWPE hip joint replacements.
    Jalali-Vahid D; Jagatia M; Jin ZM; Dowson D
    J Biomech; 2001 Feb; 34(2):261-6. PubMed ID: 11165292
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing.
    Liu F; Wang FC; Jin ZM; Hirt F; Rieker C; Grigoris P
    Proc Inst Mech Eng H; 2004; 218(4):261-70. PubMed ID: 15376728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.
    Yew A; Udofia I; Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):27-34. PubMed ID: 14982343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):247-56. PubMed ID: 9256001
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses.
    Udofia IJ; Jin ZM
    J Biomech; 2003 Apr; 36(4):537-44. PubMed ID: 12600344
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A general elastohydrodynamic lubrication analysis of artificial hip joints employing a compliant layered socket under steady state rotation.
    Wang FC; Liu F; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(5):283-91. PubMed ID: 15532994
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of elastohydrodynamic lubrication in a novel metal-on-metal hip joint replacement.
    Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2002; 216(3):185-93. PubMed ID: 12137285
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements.
    Jin ZM; Heng SM; Ng HW; Auger DD
    Proc Inst Mech Eng H; 1999; 213(4):317-27. PubMed ID: 10466363
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement.
    Wang A; Essner A; Klein R
    Proc Inst Mech Eng H; 2001; 215(2):133-9. PubMed ID: 11382072
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 3D-transient elastohydrodynamic lubrication hip implant model to compare ultra high molecular weight polyethylene with more compliant polycarbonate polyurethane acetabular cups.
    Ford A; Hua Z; Ferguson SJ; Pruitt LA; Gao L
    J Mech Behav Biomed Mater; 2021 Jul; 119():104472. PubMed ID: 33813334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design considerations for cushion form bearings in artificial hip joints.
    Dowson D; Fisher J; Jin ZM; Auger DD; Jobbins B
    Proc Inst Mech Eng H; 1991; 205(2):59-68. PubMed ID: 1840721
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface.
    Meng QE; Liu F; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 2011 Jan; 225(1):25-37. PubMed ID: 21381485
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip joint replacements.
    McClure G; Jin ZM; Fisher J; Tighe BJ
    Proc Inst Mech Eng H; 1996; 210(2):89-93. PubMed ID: 8688121
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.