179 related articles for article (PubMed ID: 11389226)
1. Evaluation of the LGM Vena-Tech infrarenal vena cava filter in an ovine venous thromboembolism model.
Crochet D; Grossetête R; Bach-Lijour B; Larguier L; Le Nihouannen JC
J Vasc Interv Radiol; 2001 Jun; 12(6):739-45. PubMed ID: 11389226
[TBL] [Abstract][Full Text] [Related]
2. In vitro flow phantom analysis and clot-capturing ability of incompletely opened Vena Tech-LGM vena caval filters.
Korbin CD; Reed RA; Taylor FC; Kokoris SP; Teitelbaum GP
Cardiovasc Intervent Radiol; 1993; 16(1):3-6. PubMed ID: 8435832
[TBL] [Abstract][Full Text] [Related]
3. Long-term follow-up of Vena Tech-LGM filter: predictors and frequency of caval occlusion.
Crochet DP; Brunel P; Trogrlic S; Grossetëte R; Auget JL; Dary C
J Vasc Interv Radiol; 1999 Feb; 10(2 Pt 1):137-42. PubMed ID: 10082099
[TBL] [Abstract][Full Text] [Related]
4. Caval incorporation of the LGM Vena Tech filter: an experimental study.
Crochet D; Bach-Lijour B; Grossetëte R; Raffin T; Nguyen JM; Hurtrel M; Daculsi G; Le Nihouannen JC
J Vasc Interv Radiol; 1997; 8(3):419-25. PubMed ID: 9152915
[TBL] [Abstract][Full Text] [Related]
5. In vitro model for the evaluation of inferior vena cava filters: effect of experimental parameters on thrombus-capturing efficacy of the Vena Tech-LGM filter.
Jaeger HJ; Kolb S; Mair T; Geller M; Christmann A; Kinne RK; Mathias KD
J Vasc Interv Radiol; 1998; 9(2):295-304. PubMed ID: 9540914
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a spiral nitinol temporary inferior vena caval filter.
Stecker MS; Barnhart WH; Lang EV
Acad Radiol; 2001 Jun; 8(6):484-93. PubMed ID: 11394541
[TBL] [Abstract][Full Text] [Related]
7. Use of a Fogarty catheter to open an incompletely expanded Vena Tech-LGM vena cava filter--a case report.
Danikas D; Constantinopoulous GS; Stratoulias C; Ginalis EM
Angiology; 2001 Apr; 52(4):283-6. PubMed ID: 11330512
[TBL] [Abstract][Full Text] [Related]
8. Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.
Huang SY; Eggers M; McArthur MJ; Dixon KA; McWatters A; Dria S; Hill LR; Melancon MP; Steele JR; Wallace MJ
Radiology; 2017 Dec; 285(3):820-829. PubMed ID: 28708470
[TBL] [Abstract][Full Text] [Related]
9. Optimal central trapping (OPCETRA) vena caval filter: results of experimental studies.
Kraimps JL; De La Faye D; Drouineau J; Bensignor E; Barbier J
J Vasc Interv Radiol; 1992 Nov; 3(4):697-701. PubMed ID: 1446131
[TBL] [Abstract][Full Text] [Related]
10. Thrombus-trapping efficiency of the LGM (Vena Tech) and titanium Greenfield filters in vivo.
Millward SF; Marsh JI; Pon C; Moher D
J Vasc Interv Radiol; 1992 Feb; 3(1):103-6. PubMed ID: 1540709
[TBL] [Abstract][Full Text] [Related]
11. Incidence and Outcomes of Inferior Vena Cava Filter Thrombus during Catheter-directed Thrombolysis for Proximal Deep Venous Thrombosis.
Jiang J; Tu J; Jia Z; Chen J; Cao H; Meng Q; Fuller TA; Tian F
Ann Vasc Surg; 2017 Jan; 38():305-309. PubMed ID: 27531087
[TBL] [Abstract][Full Text] [Related]
12. TrapEase vena cava filter: experience in 751 patients.
Kalva SP; Wicky S; Waltman AC; Athanasoulis CA
J Endovasc Ther; 2006 Jun; 13(3):365-72. PubMed ID: 16784325
[TBL] [Abstract][Full Text] [Related]
13. Suprarenal inferior vena cava filters: a 20-year single-center experience.
Kalva SP; Chlapoutaki C; Wicky S; Greenfield AJ; Waltman AC; Athanasoulis CA
J Vasc Interv Radiol; 2008 Jul; 19(7):1041-7. PubMed ID: 18589318
[TBL] [Abstract][Full Text] [Related]
14. A new optional vena cava filter: retrieval at 12 weeks in an animal model.
Brountzos EN; Kaufman JA; Venbrux AC; Brown PR; Harry J; Kinst TF; Kleshinski S; Ravenscroft AC
J Vasc Interv Radiol; 2003 Jun; 14(6):763-72. PubMed ID: 12817044
[TBL] [Abstract][Full Text] [Related]
15. Comparison of filters in an oversized vena caval phantom: intracaval placement of a bird's nest filter versus biiliac placement of Greenfield, Vena Tech-LGM, and Simon nitinol filters.
Korbin CD; Reed RA; Taylor FC; Pentecost MJ; Teitelbaum GP
J Vasc Interv Radiol; 1992 Aug; 3(3):559-64. PubMed ID: 1515730
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous venous thrombectomy using the Arrow-Trerotola percutaneous thrombolytic device (PTD) with temporary caval filtration: in vitro investigations.
Wildberger JE; Haage P; Bovelander J; Pfeffer J; Weiss C; Vorwerk D; Schmitz-Rode T; Günther RW
Cardiovasc Intervent Radiol; 2005; 28(2):221-7. PubMed ID: 15883861
[TBL] [Abstract][Full Text] [Related]
17. Suprarenal vena caval filter placement: follow-up of four filter types in 22 patients.
Matchett WJ; Jones MP; McFarland DR; Ferris EJ
J Vasc Interv Radiol; 1998; 9(4):588-93. PubMed ID: 9684828
[TBL] [Abstract][Full Text] [Related]
18. [Experiences with temporary vena cava filters in 114 at-risk patients with thrombosis or thromboembolism].
Scholz KH; Just M; Buchwald AB; Werner GS; Stille-Siegener M; Kreuzer H
Dtsch Med Wochenschr; 1999 Mar; 124(11):307-13. PubMed ID: 10209531
[TBL] [Abstract][Full Text] [Related]
19. LGM (Vena Tech) vena caval filter: experience at a single institution.
Millward SF; Peterson RA; Moher D; Lewandowski BJ; Burbridge BE; Aquino J; Formoso A
J Vasc Interv Radiol; 1994; 5(2):351-6. PubMed ID: 8186606
[TBL] [Abstract][Full Text] [Related]
20. Inferior vena cava filter placement for prevention of pulmonary tumor emboli of renal cancer with renal vein or vena caval tumor thrombus: prophylactic usage prior to transcatheter arterial embolization.
Hirota S; Matsumoto S; Yoshikawa T; Tomita M; Kono M; Sako M; Kamidono S
Radiat Med; 1998; 16(5):335-9. PubMed ID: 9862154
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]