These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 11392887)

  • 1. Reduction of the platelet review rate using the two-dimensional platelet method.
    Chapman DH; Hardin J; Miers M; Moyle S; Kinney MC
    Am J Clin Pathol; 2001 Jun; 115(6):894-8. PubMed ID: 11392887
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved platelet counting using two-dimensional laser light scatter.
    Kunicka JE; Fischer G; Murphy J; Zelmanovic D
    Am J Clin Pathol; 2000 Aug; 114(2):283-9. PubMed ID: 10941345
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Platelet counting in platelet concentrates with various automated hematology analyzers.
    Dijkstra-Tiekstra MJ; Kuipers W; Setroikromo AC; de Wildt-Eggen J
    Transfusion; 2007 Sep; 47(9):1651-7. PubMed ID: 17725730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Problems with platelet counting in thrombocytopenia. A rapid manual method to measure low platelet counts.
    Sutor AH; Grohmann A; Kaufmehl K; Wündisch T
    Semin Thromb Hemost; 2001 Jun; 27(3):237-43. PubMed ID: 11446657
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Usefulness of immunoplatelet measurement using the flow cytometric method for accurate platelet counting in hematological patients with severe thrombocytopenia].
    Nishiyama M; Hayashi S; Futsukaichi Y; Suehisa E; Kurata Y
    Rinsho Byori; 2004 Feb; 52(2):103-8. PubMed ID: 15027312
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Implementation of the immunological method for improvement on accurate platelet counts].
    Osada E; Inose Y; Takeuchi K; Kawai Y; Watanabe K
    Rinsho Byori; 2002 Sep; 50(9):887-92. PubMed ID: 12386967
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enumeration of platelets by multiparameter flow cytometry using platelet-specific antibodies and fluorescent reference particles.
    Dickerhoff R; Von Ruecker A
    Clin Lab Haematol; 1995 Jun; 17(2):163-72. PubMed ID: 8536420
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of two platelet count estimation methodologies for peripheral blood smears.
    Malok M; Titchener EH; Bridgers C; Lee BY; Bamberg R
    Clin Lab Sci; 2007; 20(3):154-60. PubMed ID: 17691671
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Platelet counting by the coulter LH 750, sysmex XE 2100, and advia 120: a comparative analysis using the RBC/platelet ratio reference method.
    Sandhaus LM; Osei ES; Agrawal NN; Dillman CA; Meyerson HJ
    Am J Clin Pathol; 2002 Aug; 118(2):235-41. PubMed ID: 12162684
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuing developments with the automated platelet count.
    Briggs C; Harrison P; Machin SJ
    Int J Lab Hematol; 2007 Apr; 29(2):77-91. PubMed ID: 17474881
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An interlaboratory study of a candidate reference method for platelet counting.
    Harrison P; Ault KA; Chapman S; Charie L; Davis B; Fujimoto K; Houwen B; Kunicka J; Lacombe F; Machin S; Raynor R; van Hove L; van Assendelft OW;
    Am J Clin Pathol; 2001 Mar; 115(3):448-59. PubMed ID: 11242802
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relationships between platelet counts, platelet volumes and reticulated platelets in patients with ITP: evidence for significant platelet count inaccuracies with conventional instrument methods.
    Diquattro M; Gagliano F; Calabrò GM; Tommasi M; Scott CS; Mancuso G; Palma B; Menozzi I
    Int J Lab Hematol; 2009 Apr; 31(2):199-206. PubMed ID: 18190589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Methods for counting platelets in severe thrombocytopenia.
    Segal HC; Harrison P
    Curr Hematol Rep; 2006 Mar; 5(1):70-5. PubMed ID: 16537049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of various hematology analyzers on component platelet counts.
    Moroff G; Sowemimo-Coker SO; Finch S; Murphy S; Brandwein H; Whitbread J; Wenz B
    Transfus Med Rev; 2005 Apr; 19(2):155-66. PubMed ID: 15852243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Possibilities and limitations of automated platelet counting procedures in the thrombocytopenic range.
    Kunz D
    Semin Thromb Hemost; 2001 Jun; 27(3):229-35. PubMed ID: 11446656
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.
    Segal HC; Briggs C; Kunka S; Casbard A; Harrison P; Machin SJ; Murphy MF
    Br J Haematol; 2005 Feb; 128(4):520-5. PubMed ID: 15686462
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Platelets in the paediatric population: the influence of age and the limitations of automation.
    Felle P; McMahon C; Rooney S; Donnelly P; Ni Chonchubhair F
    Clin Lab Haematol; 2005 Aug; 27(4):250-7. PubMed ID: 16048493
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro evaluation of platelet concentrates during storage: Platelet counts and markers of platelet destruction.
    Apelseth TO; Hervig T
    Transfus Apher Sci; 2007 Dec; 37(3):261-8. PubMed ID: 18036986
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Variable levels of carry over on platelet counts < or = 20 x 10(9)/l with the Bayer Advia 120.
    Mehmood S; Hinchliffe RF; Clark SJ; Bellamy GJ; Dennis MW; Welch JC; Vora AJ
    Int J Lab Hematol; 2007 Oct; 29(5):377-80. PubMed ID: 17824919
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Counting platelets in platelet concentrates on hematology analyzers: a multicenter comparative study.
    van der Meer PF; Dijkstra-Tiekstra MJ; Mahon A; de Wildt-Eggen J;
    Transfusion; 2009 Jan; 49(1):81-90. PubMed ID: 18954409
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.