These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 11393467)

  • 1. Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.
    Herman MG; Balter JM; Jaffray DA; McGee KP; Munro P; Shalev S; Van Herk M; Wong JW
    Med Phys; 2001 May; 28(5):712-37. PubMed ID: 11393467
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A literature review of electronic portal imaging for radiotherapy dosimetry.
    van Elmpt W; McDermott L; Nijsten S; Wendling M; Lambin P; Mijnheer B
    Radiother Oncol; 2008 Sep; 88(3):289-309. PubMed ID: 18706727
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical characterization of the varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices.
    Grattan MW; McGarry CK
    Med Phys; 2010 Apr; 37(4):1707-13. PubMed ID: 20443491
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of ghosting effects for three commercial a-Si EPIDs.
    McDermott LN; Nijsten SM; Sonke JJ; Partridge M; van Herk M; Mijnheer BJ
    Med Phys; 2006 Jul; 33(7):2448-51. PubMed ID: 16898447
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new approach in the design of electronic portal imaging devices for portal dosimetry in radiotherapy.
    Badel JN; Partouche-Sebban D; Abraham I; Carrie C
    Phys Med; 2014 Sep; 30(6):644-53. PubMed ID: 24767869
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A global calibration model for a-Si EPIDs used for transit dosimetry.
    Nijsten SM; van Elmpt WJ; Jacobs M; Mijnheer BJ; Dekker AL; Lambin P; Minken AW
    Med Phys; 2007 Oct; 34(10):3872-84. PubMed ID: 17985633
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
    Baker SJ; Budgell GJ; MacKay RI
    Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.
    Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM
    Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Commissioning and periodic quality assurance of a clinical electronic portal imaging device.
    Low DA; Klein EE; Maag DK; Umfleet WE; Purdy JA
    Int J Radiat Oncol Biol Phys; 1996 Jan; 34(1):117-23. PubMed ID: 12118539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device.
    Greer PB
    Med Phys; 2007 Oct; 34(10):3815-24. PubMed ID: 17985627
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comprehensive fluence model for absolute portal dose image prediction.
    Chytyk K; McCurdy BM
    Med Phys; 2009 Apr; 36(4):1389-98. PubMed ID: 19472646
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simplifying EPID dosimetry for IMRT treatment verification.
    Pecharromán-Gallego R; Mans A; Sonke JJ; Stroom JC; Olaciregui-Ruiz I; van Herk M; Mijnheer BJ
    Med Phys; 2011 Feb; 38(2):983-92. PubMed ID: 21452735
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of electronic portal imaging device for missing tissue compensator design and verification.
    Roback DM; Gerbi BJ
    Med Phys; 1995 Dec; 22(12):2029-34. PubMed ID: 8746708
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Source position verification and dosimetry in HDR brachytherapy using an EPID.
    Smith RL; Taylor ML; McDermott LN; Haworth A; Millar JL; Franich RD
    Med Phys; 2013 Nov; 40(11):111706. PubMed ID: 24320414
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The dose response relationship of a liquid-filled electronic portal imaging device.
    Boellaard R; van Herk M; Mijnheer BJ
    Med Phys; 1996 Sep; 23(9):1601-11. PubMed ID: 8892258
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry.
    Sabet M; Menk FW; Greer PB
    Med Phys; 2010 Apr; 37(4):1459-67. PubMed ID: 20443467
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Guide to clinical use of electronic portal imaging.
    Herman MG; Kruse JJ; Hagness CR
    J Appl Clin Med Phys; 2000; 1(2):38-57. PubMed ID: 11674818
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of optical transport effects on EPID dosimetry using Geant4.
    Blake SJ; Vial P; Holloway L; Greer PB; McNamara AL; Kuncic Z
    Med Phys; 2013 Apr; 40(4):041708. PubMed ID: 23556878
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine.
    Nath R; Anderson LL; Meli JA; Olch AJ; Stitt JA; Williamson JF
    Med Phys; 1997 Oct; 24(10):1557-98. PubMed ID: 9350711
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
    Tyner E; McClean B; McCavana P; af Wetterstedt S
    Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.