These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
174 related articles for article (PubMed ID: 11393471)
1. Monte Carlo-aided dosimetry of the Source Tech Medical Model STM1251 I-125 interstitial brachytherapy source. Kirov AS; Williamson JF Med Phys; 2001 May; 28(5):764-72. PubMed ID: 11393471 [TBL] [Abstract][Full Text] [Related]
2. Monte Carlo-aided dosimetry of the Symmetra model I25.S06 125I, interstitial brachytherapy seed. Hedtjärn H; Carlsson GA; Williamson JF Med Phys; 2000 May; 27(5):1076-85. PubMed ID: 10841412 [TBL] [Abstract][Full Text] [Related]
3. Monte Carlo-aided dosimetry of the theragenics TheraSeed model 200 103Pd interstitial brachytherapy seed. Monroe JI; Williamson JF Med Phys; 2002 Apr; 29(4):609-21. PubMed ID: 11991133 [TBL] [Abstract][Full Text] [Related]
4. Dosimetric characteristics of the DRAXIMAGE model LS-1 1-125 interstitial brachytherapy source design: a Monte Carlo investigation. Williamson JF Med Phys; 2002 Apr; 29(4):509-21. PubMed ID: 11991122 [TBL] [Abstract][Full Text] [Related]
5. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Rivard MJ; Coursey BM; DeWerd LA; Hanson WF; Huq MS; Ibbott GS; Mitch MG; Nath R; Williamson JF Med Phys; 2004 Mar; 31(3):633-74. PubMed ID: 15070264 [TBL] [Abstract][Full Text] [Related]
6. Monte Carlo-aided dosimetry of the new Bebig IsoSeed 103Pd interstitial brachytherapy seed. Daskalov GM; Williamson JF Med Phys; 2001 Oct; 28(10):2154-61. PubMed ID: 11695778 [TBL] [Abstract][Full Text] [Related]
7. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed. Lymperopoulou G; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Przykutta A; Baltas D Med Phys; 2005 Nov; 32(11):3313-7. PubMed ID: 16370418 [TBL] [Abstract][Full Text] [Related]
8. Monte Carlo dosimetry of the selectSeed 125I interstitial brachytherapy seed. Karaiskos P; Papagiannis P; Sakelliou L; Anagnostopoulos G; Baltas D Med Phys; 2001 Aug; 28(8):1753-60. PubMed ID: 11548946 [TBL] [Abstract][Full Text] [Related]
9. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism. Ho Than MT; Munro Iii JJ; Medich DC J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489 [TBL] [Abstract][Full Text] [Related]
10. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom. Chiu-Tsao ST; Medich D; Munro J Med Phys; 2008 Aug; 35(8):3787-99. PubMed ID: 18777938 [TBL] [Abstract][Full Text] [Related]
11. A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an 125I seed already having AAPM consensus data. Aryal P; Molloy JA; Rivard MJ Med Phys; 2014 Feb; 41(2):021702. PubMed ID: 24506593 [TBL] [Abstract][Full Text] [Related]
12. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source. Chan GH; Prestwich WV Med Phys; 2002 Sep; 29(9):1984-90. PubMed ID: 12349919 [TBL] [Abstract][Full Text] [Related]
13. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source. Meigooni AS; Hayes JL; Zhang H; Sowards K Med Phys; 2002 Sep; 29(9):2152-8. PubMed ID: 12349937 [TBL] [Abstract][Full Text] [Related]
14. Monte Carlo calculations and experimental measurements of the TG-43U1-recommended dosimetric parameters of 125I (Model IR-Seed2) brachytherapy source. Sheikholeslami S; Nedaie HA; Sadeghi M; Pourbeigy H; Shahzadi S; Zehtabian M; Hasani M; Meigooni AS J Appl Clin Med Phys; 2016 Jul; 17(4):430-441. PubMed ID: 27455485 [TBL] [Abstract][Full Text] [Related]
15. Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink 125Iodine brachytherapy system. Medich DC; Munro JJ Med Phys; 2003 Sep; 30(9):2503-8. PubMed ID: 14528972 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric characteristics of the Pharma Seed model BT-125-I source. Popescu CC; Wise J; Sowards K; Meigooni AS; Ibbott GS Med Phys; 2000 Sep; 27(9):2174-81. PubMed ID: 11011748 [TBL] [Abstract][Full Text] [Related]
17. Monte Carlo modeling of the transverse-axis dose distribution of the model 200 103Pd interstitial brachytherapy source. Williamson JF Med Phys; 2000 Apr; 27(4):643-54. PubMed ID: 10798684 [TBL] [Abstract][Full Text] [Related]
18. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy. Hiatt JR; Rivard MJ; Hughes HG Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699 [TBL] [Abstract][Full Text] [Related]
19. A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model. Hiatt JR; Davis SD; Rivard MJ Med Phys; 2015 Jun; 42(6):2764-76. PubMed ID: 26127029 [TBL] [Abstract][Full Text] [Related]
20. Thermoluminescent dosimetry of the SourceTech Medical model STM1251 125I seed. Chiu-Tsao ST; Duckworth TL; Hsiung CY; Li Z; Williamson J; Patel NS; Harrison LB Med Phys; 2003 Jul; 30(7):1732-5. PubMed ID: 12906190 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]