These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 11394299)

  • 1. Application of central composite designs for optimisation of the chromatographic separation of monomethylarsonate and dimethylarsinate and of selenomethionine and selenite by ion-pair chromatography coupled with plasma mass spectrometric detection.
    Do B; Robinet S; Pradeau D; Guyon F
    Analyst; 2001 May; 126(5):594-601. PubMed ID: 11394299
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Speciation of arsenic and selenium compounds by ion-pair reversed-phase chromatography with electrothermic atomic absorption spectrometry. Application of experimental design for chromatographic optimisation.
    Do B; Robinet S; Pradeau D; Guyon F
    J Chromatogr A; 2001 May; 918(1):87-98. PubMed ID: 11403459
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous characterization of selenium and arsenic analytes via ion-pairing reversed phase chromatography with inductively coupled plasma and electrospray ionization ion trap mass spectrometry for detection applications to river water, plant extract and urine matrices.
    Afton S; Kubachka K; Catron B; Caruso JA
    J Chromatogr A; 2008 Oct; 1208(1-2):156-63. PubMed ID: 18778826
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multielemental determination of arsenic, selenium and chromium(VI) species in water by high-performance liquid chromatography-inductively coupled plasma mass spectrometry.
    Martínez-Bravo Y; Roig-Navarro AF; López FJ; Hernández F
    J Chromatogr A; 2001 Aug; 926(2):265-74. PubMed ID: 11556332
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selenium metabolites in human urine after ingestion of selenite, L-selenomethionine, or DL-selenomethionine: a quantitative case study by HPLC/ICPMS.
    Kuehnelt D; Kienzl N; Traar P; Le NH; Francesconi KA; Ochi T
    Anal Bioanal Chem; 2005 Sep; 383(2):235-46. PubMed ID: 16132136
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficient interface for online coupling of capillary electrophoresis with inductively coupled plasma-mass spectrometry and its application in simultaneous speciation analysis of arsenic and selenium.
    Liu L; Yun Z; He B; Jiang G
    Anal Chem; 2014 Aug; 86(16):8167-75. PubMed ID: 25082790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Rapid determination of trace iodate using monolithic column ion-pair chromatography coupled with direct conductivity detection].
    Liu Y; Yu H; Li S
    Se Pu; 2011 Oct; 29(10):1036-40. PubMed ID: 22268363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of selenium and tellurium compounds in biological samples by ion chromatography dynamic reaction cell inductively coupled plasma mass spectrometry.
    Kuo CY; Jiang SJ
    J Chromatogr A; 2008 Feb; 1181(1-2):60-6. PubMed ID: 18199446
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Identification of trace levels of selenomethionine and related organic selenium species in high-ionic-strength waters.
    LeBlanc KL; Ruzicka J; Wallschläger D
    Anal Bioanal Chem; 2016 Feb; 408(4):1033-42. PubMed ID: 26547190
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Study on reversed-phase ion-pair chromatographic determination of thiosulfate and iodide anions].
    Zhang X; Yun Z
    Se Pu; 1997 Jan; 15(1):57-9. PubMed ID: 15739437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New separation method for organic and inorganic selenium compounds based on anion exchange chromatography followed by inductively coupled plasma mass spectrometry.
    Ayouni L; Barbier F; Imbert JL; Gauvrit JY; Lantéri P; Grenier-Loustalot MF
    Anal Bioanal Chem; 2006 Aug; 385(8):1504-12. PubMed ID: 16858565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Speciation analysis of arsenic and selenium compounds in environmental and biological samples by ion chromatography-inductively coupled plasma dynamic reaction cell mass spectrometer.
    Wang RY; Hsu YL; Chang LF; Jiang SJ
    Anal Chim Acta; 2007 May; 590(2):239-44. PubMed ID: 17448350
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of ion-pairing and ion-suppressing liquid chromatographic methods for the determination of pyrimethamine and ormetoprim in chicken feed.
    Lin SY; Jeng SL
    J Chromatogr Sci; 2002 Jul; 40(6):331-6. PubMed ID: 12137205
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of sodium selenite and L-selenomethionine on feed intake, clinically relevant blood parameters and selenium species in plasma, colostrum and milk from high-yielding sows.
    Falk M; Lebed P; Bernhoft A; Framstad T; Kristoffersen AB; Salbu B; Oropeza-Moe M
    J Trace Elem Med Biol; 2019 Mar; 52():176-185. PubMed ID: 30732879
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Speciation of arsenic and selenium by capillary electrophoresis.
    Sun B; Macka M; Haddad PR
    J Chromatogr A; 2004 Jun; 1039(1-2):201-8. PubMed ID: 15250424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of selenoamino acids using two-dimensional ion-pair reversed phase chromatography with on-line detection by inductively coupled plasma mass spectrometry.
    Zheng J; Shibata Y; Furuta N
    Talanta; 2003 Jan; 59(1):27-36. PubMed ID: 18968881
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of selenium compounds in urine by high-performance liquid chromatography--inductively coupled plasma mass spectrometry.
    Chatterjee A; Tao H; Shibata Y; Morita M
    J Chromatogr A; 2003 May; 997(1-2):249-57. PubMed ID: 12830899
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On-line separation and preconcentration of inorganic arsenic and selenium species in natural water samples with CTAB-modified alkyl silica microcolumn and determination by inductively coupled plasma-optical emission spectrometry.
    Xiong C; He M; Hu B
    Talanta; 2008 Aug; 76(4):772-9. PubMed ID: 18656657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Capabilities of microbore columns coupled to inductively coupled plasma mass spectrometry in speciation of arsenic and selenium.
    Castillo A; Roig-Navarro AF; Pozo OJ
    J Chromatogr A; 2008 Aug; 1202(2):132-7. PubMed ID: 18640681
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arsenic speciation by gradient anion exchange narrow bore ion chromatography and high resolution inductively coupled plasma mass spectrometry detection.
    Ammann AA
    J Chromatogr A; 2010 Apr; 1217(14):2111-6. PubMed ID: 20188376
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.