These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 11395702)

  • 1. Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part II: Deactivation forces.
    Santoro M; Nicolay OF; Cangialosi TJ
    Am J Orthod Dentofacial Orthop; 2001 Jun; 119(6):594-603. PubMed ID: 11395702
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: Temperature transitional ranges.
    Santoro M; Nicolay OF; Cangialosi TJ
    Am J Orthod Dentofacial Orthop; 2001 Jun; 119(6):587-93. PubMed ID: 11395701
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Force-deflection properties of initial orthodontic archwires.
    Quintão CC; Cal-Neto JP; Menezes LM; Elias CN
    World J Orthod; 2009; 10(1):29-32. PubMed ID: 19388430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Force levels of 23 nickel-titanium open-coil springs in compression testing.
    Brauchli LM; Senn C; Ball J; Wichelhaus A
    Am J Orthod Dentofacial Orthop; 2011 May; 139(5):601-5. PubMed ID: 21536202
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of temperature on the elastic responses to longitudinal torsion of rectangular nickel titanium archwires.
    Meling TR; Odegaard J
    Angle Orthod; 1998 Aug; 68(4):357-68. PubMed ID: 9709837
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nickel-titanium spring properties in a simulated oral environment.
    Han S; Quick DC
    Angle Orthod; 1993; 63(1):67-72. PubMed ID: 8507034
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Superelastic nickel titanium spring clips for the SPEED appliance.
    Hanson GH
    J Clin Orthod; 2002 Sep; 36(9):520-3. PubMed ID: 12374040
    [No Abstract]   [Full Text] [Related]  

  • 8. Elastic properties of alternative versus single-stranded leveling archwires.
    Rucker BK; Kusy RP
    Am J Orthod Dentofacial Orthop; 2002 Nov; 122(5):528-41. PubMed ID: 12439482
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The NiTi superelastic alloy application to the dentistry field.
    Torrisi L
    Biomed Mater Eng; 1999; 9(1):39-47. PubMed ID: 10436852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending.
    Meling TR; Odegaard J
    Am J Orthod Dentofacial Orthop; 2001 Mar; 119(3):263-73. PubMed ID: 11244421
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Definitions and thermodynamic behavior of metal alloys].
    Orthod Fr; 2001 Sep; 72(3):233-44. PubMed ID: 11678012
    [No Abstract]   [Full Text] [Related]  

  • 12. Estimation of force produced by nickel-titanium superelastic archwires at large deflections.
    Muraviev SE; Ospanova GB; Shlyakhova MY
    Am J Orthod Dentofacial Orthop; 2001 Jun; 119(6):604-9. PubMed ID: 11395703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of ligation on the load deflection characteristics of nickel titanium orthodontic wire.
    Kasuya S; Nagasaka S; Hanyuda A; Ishimura S; Hirashita A
    Eur J Orthod; 2007 Dec; 29(6):578-82. PubMed ID: 17873145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparisons of the thermodynamic properties of three nickel-titanium orthodontic archwires.
    Bishara SE; Winterbottom JM; Sulieman AH; Rim K; Jakobsen JR
    Angle Orthod; 1995; 65(2):117-22. PubMed ID: 7785802
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Can the level of rebound force be augmented in re-ligating a nickel-titanium arch? Discussion of the report of the Congress of Lille (Orthod Fr 2009;80(1):1-148)].
    Filleul MP
    Orthod Fr; 2009 Dec; 80(4):415-8. PubMed ID: 19954739
    [No Abstract]   [Full Text] [Related]  

  • 16. In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.
    Eliades T; Athanasiou AE
    Angle Orthod; 2002 Jun; 72(3):222-37. PubMed ID: 12071606
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys.
    Krishnan M; Kalathil S; Abraham KM
    Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):675-82. PubMed ID: 19892284
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temperature effects on the forces, moments and moment to force ratio of nickel-titanium and TMA symmetrical T-loops.
    Lim Y; Quick A; Swain M; Herbison P
    Angle Orthod; 2008 Nov; 78(6):1035-42. PubMed ID: 18947274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nickel-titanium alloys: stress-related temperature transitional range.
    Santoro M; Beshers DN
    Am J Orthod Dentofacial Orthop; 2000 Dec; 118(6):685-92. PubMed ID: 11113804
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.
    Matarese G; Nucera R; Militi A; Mazza M; Portelli M; Festa F; Cordasco G
    Am J Orthod Dentofacial Orthop; 2008 May; 133(5):708-15. PubMed ID: 18456144
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.