These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 11397981)

  • 1. [Histologic evaluation in rabbits of the biocompatibility of episcleral implant material: S-PTFEe (silicone core covered with expanded polytetrafluoroethylene)].
    Mortemousque B; Diemer C; Léger F; Barac'h D; Legeais JM; Williamson W
    J Fr Ophtalmol; 2001 May; 24(5):467-73. PubMed ID: 11397981
    [TBL] [Abstract][Full Text] [Related]  

  • 2. S/e-PTFE episcleral buckling implants: an experimental and histopathologic study.
    Mortemousque B; Leger F; Velou S; Graffan R; Colin J; Korobelnik JF
    J Biomed Mater Res; 2002; 63(6):686-91. PubMed ID: 12418011
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polytetrafluoroethylene in experimental retinal detachment surgery.
    Lobes LA; Grand MG; Rehkopf PG; Johnson B
    Ann Ophthalmol; 1981 Aug; 13(8):921-3. PubMed ID: 7294633
    [TBL] [Abstract][Full Text] [Related]  

  • 4. e-PTFE as scleral buckling episcleral implants: an experimental and histopathologic study.
    Korobelnik JF; D'Hermies F; Ducourneau D; Legeais JM; Chauvaud D; Hoang-Xuan T; Renard G
    J Biomed Mater Res; 1999; 48(6):807-13. PubMed ID: 10556844
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of alloplast materials in experimental extraocular muscle surgery.
    Ugurbas SC; Kocer NE; Oto S; Kahraman B; Akova YA
    Ophthalmic Res; 2010; 44(1):50-6. PubMed ID: 20215807
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of gastric bands of different synthetic materials on the gastric and esophageal mucosa: an experimental study.
    Bozbora A; Coskun H; Barbaros U; Sari S; Asoglu O
    Obes Surg; 2004 Feb; 14(2):246-52. PubMed ID: 15018755
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tissue response to expanded polytetrafluoroethylene and silicone implants in a rabbit model.
    Batniji RK; Hutchison JL; Dahiya R; Lam SL; Williams EF
    Arch Facial Plast Surg; 2002; 4(2):111-3. PubMed ID: 12020206
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scleral reinforcement in rabbits using synthetic graft materials.
    Whitmore WG; Harrison W; Curtin BJ
    Ophthalmic Surg; 1990 May; 21(5):327-30. PubMed ID: 2143288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Tissue colonization of expanded polytetrafluoroethylene in healthy cornea in the view of its use as a support in keratoprosthesis].
    Legeais JM; Renard G; Savoldelli M; Keller N
    J Fr Ophtalmol; 1988; 11(11):727-32. PubMed ID: 3074974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Slow-releasing paclitaxel in polytetrafluoroethylene/polylactide-co-glycolide laminate delays adjustment after strabismus surgery in rabbit model.
    Choung HK; Jin SE; Lee MJ; Kim CK; Hwang JM
    Invest Ophthalmol Vis Sci; 2008 Dec; 49(12):5340-5. PubMed ID: 18708626
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Expanded polytetrafluoroethylene episcleral implants used as encircling scleral buckling. an experimental and histopathological study.
    Korobelnik JF; D'Hermies F; Chauvaud D; Legeais JM; Hoang-Xuan T; Renard G
    Ophthalmic Res; 2000; 32(2-3):110-7. PubMed ID: 10754444
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Slow-releasing tranilast in polytetrafluoroethylene/polylactide-co-glycolide laminate delays adjustment after strabismus surgery in rabbit model.
    Lee MJ; Jin SE; Kim CK; Choung HK; Jeoung JW; Kim HJ; Choe G; Hwang JM
    Invest Ophthalmol Vis Sci; 2007 Feb; 48(2):699-704. PubMed ID: 17251468
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of polyethylene terephthalate and expanded-polytetrafluoroethylene in medialization laryngoplasty.
    Keskin G; Boyaci Z; Ustundag E; Kaur A; Almaç A
    J Laryngol Otol; 2003 Apr; 117(4):294-7. PubMed ID: 12816219
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Soft tissue response of the larynx to silicone, Gore-Tex, and irradiated cartilage implants.
    Ustundag E; Boyaci Z; Keskin G; Kaur A; Ozkarakas H
    Laryngoscope; 2005 Jun; 115(6):1009-14. PubMed ID: 15933511
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Synthetic scleral reinforcement materials: I. Development and in vivo tissue biocompatibility response.
    Jacob-LaBarre JT; Assouline M; Byrd T; McDonald M
    J Biomed Mater Res; 1994 Jun; 28(6):699-712. PubMed ID: 8071381
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery.
    Jacob T; LaCour OJ; Burgoyne CF; LaFleur PK; Duzman E
    J Glaucoma; 2001 Apr; 10(2):115-20. PubMed ID: 11316093
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Keratoprosthesis: study of an expanded polytetrafluoroethylene support].
    Legeais JM; Renard G
    J Fr Ophtalmol; 1987; 10(6-7):425-33. PubMed ID: 3320170
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contribution of vascular catheter material to the pathogenesis of infection: the enhanced risk of silicone in vivo.
    Sherertz RJ; Carruth WA; Marosok RD; Espeland MA; Johnson RA; Solomon DD
    J Biomed Mater Res; 1995 May; 29(5):635-45. PubMed ID: 7622549
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anterior segment prosthesis development: evaluation of expanded polytetrafluoroethylene as a sclera-attached prosthetic material.
    Guo A; Rife LL; Rao NA; Smith RE
    Cornea; 1996 Mar; 15(2):210-4. PubMed ID: 8925671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison between textured silicone implants and those bonded with expanded polytetrafluoroethylene in rats.
    Haddad Filho D; Zveibel DK; Alonso N; Gemperli R
    Acta Cir Bras; 2007; 22(3):187-94. PubMed ID: 17546291
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.