These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 114007)

  • 1. New techniques for CT-guided biopsies.
    Haaga JR
    AJR Am J Roentgenol; 1979 Oct; 133(4):633-41. PubMed ID: 114007
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [CT-guided thoracic biopsy. Personal experience with DBNH Haaga 20 G needles].
    Consalvo M; Ricupero L; Lascialfari L; Salani G; Arganini L; Di Lollo S; Masi A
    Radiol Med; 1993 Sep; 86(3):234-9. PubMed ID: 8210531
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [CT-guided punctures: fine-needle biopsy vs. automated co-axial cutting biopsy].
    Skamel HJ; Hanusch A; Mathias K
    Aktuelle Radiol; 1998 Nov; 8(6):273-7. PubMed ID: 9894526
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adequacy and complications of CT-guided percutaneous biopsy: a study of 334 cases in Srinagarind Hospital.
    Laopaiboon V; Aphinives C; Suporntreetriped K
    J Med Assoc Thai; 2009 Jul; 92(7):939-46. PubMed ID: 19626814
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pancreatic transplants: CT-guided biopsy.
    Bernardino M; Fernandez M; Neylan J; Hertzler G; Whelchel J; Olson R
    Radiology; 1990 Dec; 177(3):709-11. PubMed ID: 2243974
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Biopsy].
    Kanazawa S; Yasui K; Kono Y; Mimura H; Tanaka A; Dendo S; Hiraki T; Yoshimura K; Takahara R; Hiraki Y
    Nihon Igaku Hoshasen Gakkai Zasshi; 2000 Dec; 60(14):833-8. PubMed ID: 11197833
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CT-guided liver biopsies: eight years' experience. Work in progress.
    Martino CR; Haaga JR; Bryan PJ; LiPuma JP; El Yousef SJ; Alfidi RJ
    Radiology; 1984 Sep; 152(3):755-7. PubMed ID: 6463257
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adequacy and complications of computed tomography-guided core needle biopsy on non-small cell lung cancers for epidermal growth factor receptor mutations demonstration: 18-gauge or 20-gauge biopsy needle.
    Cheung YC; Chang JW; Hsieh JJ; Lin G; Tsai YH
    Lung Cancer; 2010 Feb; 67(2):166-9. PubMed ID: 19450892
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Smaller and deeper lesions increase the number of acquired scan series in computed tomography-guided lung biopsy.
    Walsh CJ; Sapkota BH; Kalra MK; Hanumara NC; Liu B; Shepard JA; Gupta R
    J Thorac Imaging; 2011 Aug; 26(3):196-203. PubMed ID: 21263356
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT-guided cutting-needle biopsies of selected chest lesions.
    Goralnik CH; O'Connell DM; el Yousef SJ; Haaga JR
    AJR Am J Roentgenol; 1988 Nov; 151(5):903-7. PubMed ID: 3263019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CT-guided intervention with low radiation dose: feasibility and experience.
    Lucey BC; Varghese JC; Hochberg A; Blake MA; Soto JA
    AJR Am J Roentgenol; 2007 May; 188(5):1187-94. PubMed ID: 17449757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose.
    Prosch H; Stadler A; Schilling M; Bürklin S; Eisenhuber E; Schober E; Mostbeck G
    Eur J Radiol; 2012 May; 81(5):1029-33. PubMed ID: 21752567
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [CT-guided biopsy. Comments on the puncture technique].
    Wimmer B; Hauenstein KH
    Radiologe; 1991 Mar; 31(3):120-4. PubMed ID: 2041865
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Fine-needle and incisional biopsy technics in the percutaneous puncture of abdominal space-occupying lesions].
    Berger H; Permanetter W; Steiner W; Markl A
    Radiologe; 1988 Jun; 28(6):265-8. PubMed ID: 3399672
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Needle holder for use with a biopsy gun.
    Chenoweth JL; Patel B
    Radiology; 1991 Oct; 181(1):285-6. PubMed ID: 1887049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fine-needle aspiration biopsy of the central nervous system performed freehand under computed tomography guidance without stereotactic instrumentation.
    Seliem RM; Assaad MW; Gorombey SJ; Moral LA; Kirkwood JR; Otis CN
    Cancer; 2003 Oct; 99(5):277-84. PubMed ID: 14579294
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fine-needle aspiration biopsy of solid pancreatic masses: comparison of CT and endoscopic sonography guidance.
    Erturk SM; Mortelé KJ; Tuncali K; Saltzman JR; Lao R; Silverman SG
    AJR Am J Roentgenol; 2006 Dec; 187(6):1531-5. PubMed ID: 17114547
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CT-guided automated needle biopsy of the chest.
    Haramati LB
    AJR Am J Roentgenol; 1995 Jul; 165(1):53-5. PubMed ID: 7785631
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Image-guided pleural biopsy: diagnostic yield and complications.
    Benamore RE; Scott K; Richards CJ; Entwisle JJ
    Clin Radiol; 2006 Aug; 61(8):700-5. PubMed ID: 16843755
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [CT-guided needle biopsy in malignant lymphoma: current techniques and its usefulness].
    Kono Y; Kanazawa S; Hiraki Y
    Nihon Rinsho; 2000 Mar; 58(3):624-8. PubMed ID: 10741135
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.