These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 11405534)

  • 1. The bias flow nitrogen washout technique for measuring the functional residual capacity in infants. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing.
    Morris MG; Gustafsson P; Tepper R; Gappa M; Stocks J;
    Eur Respir J; 2001 Mar; 17(3):529-36. PubMed ID: 11405534
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plethysmographic measurements of lung volume and airway resistance. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/ American Thoracic Society.
    Stocks J; Godfrey S; Beardsmore C; Bar-Yishay E; Castile R;
    Eur Respir J; 2001 Feb; 17(2):302-12. PubMed ID: 11334135
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modification of the open circuit N2 washout technique for measurement of functional residual capacity in premature infants.
    Hentschel R; Suska A; Volbracht A; Brune T; Jorch G
    Pediatr Pulmonol; 1997 Jun; 23(6):434-41. PubMed ID: 9220526
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comprehensive integrated spirometry using raised volume passive and forced expirations and multiple-breath nitrogen washout in infants.
    Morris MG
    Respir Physiol Neurobiol; 2010 Feb; 170(2):123-40. PubMed ID: 19897058
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel physiological investigation of the functional residual capacity by the bias flow nitrogen washout technique in infants.
    Morris MG
    Pediatr Pulmonol; 2009 Jul; 44(7):683-92. PubMed ID: 19499588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of functional residual capacity using nitrogen washout and plethysmographic techniques in infants with and without bronchopulmonary dysplasia.
    Wauer RR; Maurer T; Nowotny T; Schmalisch G
    Intensive Care Med; 1998 May; 24(5):469-75. PubMed ID: 9660263
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring of functional residual capacity by an oxygen washin/washout; technical description and evaluation.
    Weismann D; Reissmann H; Maisch S; Füllekrug B; Schulte J
    J Clin Monit Comput; 2006 Aug; 20(4):251-60. PubMed ID: 16832581
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.
    Ibañez J; Raurich JM; Moris SG
    Intensive Care Med; 1983; 9(2):91-3. PubMed ID: 6343447
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of multiple-breath washout equipment for infants and young children.
    Schmidt A; Yammine S; Proietti E; Frey U; Latzin P; Riedel T; Singer F
    Pediatr Pulmonol; 2015 Jun; 50(6):607-14. PubMed ID: 24574166
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel non-invasive technique for measuring the residual lung volume by nitrogen washout with rapid thoracoabdominal compression in infants.
    Morris MG
    Thorax; 1999 Oct; 54(10):874-83. PubMed ID: 10491449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of helium dilution and nitrogen washout measurements of functional residual capacity in premature infants.
    Yuksel B; Greenough A; Chan V; Russell RR
    Pediatr Pulmonol; 1993 Sep; 16(3):197-200. PubMed ID: 8309745
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of a photoacoustic gas analyser for the measurement of functional residual capacity using multiple-breath inert gas washout.
    Gonem S; Singer F; Corkill S; Singapuri A; Siddiqui S; Gustafsson P
    Respiration; 2014; 87(6):462-8. PubMed ID: 24525760
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel methodology to perform sulfur hexafluoride (SF6)-based multiple-breath wash-in and washout in infants using current commercially available equipment.
    Gustafsson PM; Robinson PD; Lindblad A; Oberli D
    J Appl Physiol (1985); 2016 Nov; 121(5):1087-1097. PubMed ID: 27493195
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patients. Accuracy depends on continuous dynamic compensation for changes of gas sampling delay time.
    Wrigge H; Sydow M; Zinserling J; Neumann P; Hinz J; Burchardi H
    Intensive Care Med; 1998 May; 24(5):487-93. PubMed ID: 9660266
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The open circuit nitrogen washout technique for measuring the lung volume in infants: methodological aspects.
    Morris MG
    Thorax; 1999 Sep; 54(9):790-5. PubMed ID: 10456971
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tidal forced expirations. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/American Thoracic Society.
    Sly PD; Tepper R; Henschen M; Gappa M; Stocks J
    Eur Respir J; 2000 Oct; 16(4):741-8. PubMed ID: 11106222
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Measuring lung volume in the infant--problems with the nitrogen washout method].
    Modl M; Steinbrugger B; Eber E; Weinhandl E; Zach M
    Pneumologie; 1994 Oct; 48(10):754-60. PubMed ID: 7808990
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Functional residual capacity and respiratory mechanics as indicators of aeration and collapse in experimental lung injury.
    Rylander C; Högman M; Perchiazzi G; Magnusson A; Hedenstierna G
    Anesth Analg; 2004 Mar; 98(3):782-9, table of contents. PubMed ID: 14980937
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of helium dilution and nitrogen washout measurements of functional residual capacity in infants and very young children.
    Tepper RS; Asdell S
    Pediatr Pulmonol; 1992 Aug; 13(4):250-4. PubMed ID: 1523037
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of high lung volumes by nitrogen washout method.
    Sivan Y; Hammer J; Newth CJ
    J Appl Physiol (1985); 1994 Sep; 77(3):1562-4. PubMed ID: 7836166
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.